ملخص المحتوى في الصفحة رقم 1
Hi-Speed USB Carrier
NI USB-9162
Hi-SPeed USB Carrier
NI USB-9162
USER GUIDE AND SPECIFICATIONS
NI USB-9219
4-Channel, 24-Bit, Universal Analog Input Module
This user guide describes how to use the National Instruments USB-9219
and lists the device specifications.
Introduction
The NI USB-9219 provides a USB interface for four channels of universal
analog input with integrated signal conditioning. The NI USB-9219
consists of two components: an NI 9219 module, and an NI USB-9162
carrier, as sh
ملخص المحتوى في الصفحة رقم 2
Dimensions Figure 2 shows the NI USB-9219 device dimensions. Hi-Speed USB Carrier NI USB-9162 120.68 mm (4.751 in.) 118.26 mm (4.656 in.) 88.12 mm 25.34 mm (3.469 in.) (0.998 in.) Figure 2. NI USB-9219 Device in Millimeters (Inches) Safety Guidelines Operate the NI USB-9219 only as described in these operating instructions. Hot Surface This icon denotes that the component may be hot. Touching this component may result in bodily injury. Safety Guidelines for Hazardous Voltages If hazardous vo
ملخص المحتوى في الصفحة رقم 3
Caution When module terminals are hazardous voltage LIVE (>42.4 V /60 VDC), you pk must ensure that devices and circuits connected to the module are properly insulated from human contact. You must use the NI 9972 connector backshell kit, as illustrated in Figure 3 to ensure that the terminals are not accessible. Figure 3. NI 9972 Connector Backshell Related Documentation Each application software package and driver includes information about writing applications for taking measurements and
ملخص المحتوى في الصفحة رقم 4
LabVIEW If you are a new user, use the Getting Started with LabVIEW manual to familiarize yourself with the LabVIEW graphical programming environment and the basic LabVIEW features you use to build data acquisition and instrument control applications. Open the Getting Started with LabVIEW manual by selecting Start»All Programs»National Instruments»LabVIEW»LabVIEW Manuals or by navigating to the labview\manuals directory and opening LV_Getting_Started.pdf. Use the LabVIEW Help, available b
ملخص المحتوى في الصفحة رقم 5
can create channels and tasks, and write your own applications in your ADE using the NI-DAQmx API. For help with NI-DAQmx methods and properties, refer to the NI-DAQmx .NET Class Library or the NI-DAQmx Visual C++ Class Library included in the NI Measurement Studio Help. For general help with programming in Measurement Studio, refer to the NI Measurement Studio Help, which is fully integrated with the Microsoft Visual Studio .NET help. To view this help file in Visual Studio. NET, select M
ملخص المحتوى في الصفحة رقم 6
Library»Using the Measurement Studio .NET Class Libraries to view conceptual topics for using NI-DAQmx with Visual C# and Visual Basic .NET. To get to the same help topics from within Visual Studio, go to Help» Contents. Select Measurement Studio from the Filtered By drop-down list and follow the previous instructions. Device Documentation and Specifications NI-DAQmx includes the Device Document Browser, which contains online documentation for supported DAQ, SCXI, and switch devices, such a
ملخص المحتوى في الصفحة رقم 7
Example Programs The NI-DAQmx CD contains example programs that you can use to get started programming with the NI USB-9219. Refer to the NI-DAQmx for USB Devices Getting Started Guide that shipped with your device, and is also accessible from Start»All Programs»National Instruments» NI-DAQ, for more information. Installing the NI USB-9219 Device Before installing the device, you must install the software you plan to use with the device. Refer to the Installing the Software section of this g
ملخص المحتوى في الصفحة رقم 8
5. Press firmly on the connector side of the NI USB-9219 module until the latches lock the module into place, as shown in Figure 5. Figure 5. Locking Module into Place 6. Connect the USB cable to the assembled NI USB-9219. Mounting the NI USB-9219 to a Panel Threaded inserts are located in the NI USB-9219 for mounting it to a panel. Refer to Figure 6 for dimensions. 85.7 mm (3.37 in.) 72.2 mm (2.84 in.) Threaded Insert M3 x 0.5 8.5 mm (0.34 in.) Max Depth 76.1 mm (3.00 in.) Figure 6. Module
ملخص المحتوى في الصفحة رقم 9
Connecting the NI USB-9219 to a Computer Plug one end of the USB cable into the NI USB-9219 and the other end into an available USB port on the computer. Refer to the NI-DAQmx for USB Devices Getting Started Guide that shipped with your device, and is also accessible from Start»All Programs»National Instruments»NI-DAQ, for more information. LED Indicator The NI USB-9219 device has a green LED next to the USB connector. The LED indicator indicates device status, as listed in Table 1. When th
ملخص المحتوى في الصفحة رقم 10
Wiring the NI USB-9219 Device Caution A high voltage screw terminal backshell must be installed when using hazardous voltages (>42.4 V , 60 VDC). pk Note Table 2 illustrates the accessories available from ni.com for use with the NI USB-9219. Table 2. Accessories Accessory Accessory Description NI 9972 Strain relief for 6-position spring terminal NI 9973 6-position connectors The NI USB-9219 has four 6-terminal connectors that provide connections for four analog input channels. Connect the p
ملخص المحتوى في الصفحة رقم 11
Table 4. Terminal Assignments Terminal Mode 1 2 3 4 5 6 Voltage T+ T– — HI LO — Current T+ T– HI — LO — 4-Wire Resistance T+ T– EX+ HI EX– LO 2-Wire Resistance T+ T– HI — LO — Thermocouple T+ T– — HI LO — 4-Wire RTD T+ T– EX+ HI EX– LO 3-Wire RTD T+ T– EX+ — EX– LO Quarter-Bridge T+ T– HI — LO — Half-Bridge T+ T– EX+ HI EX– — Full-Bridge T+ T– EX+ HI EX– LO Digital In T+ T– — HI LO — Open Contact T+ T– HI — LO — Connecting Wires to the NI USB-9219 Connectors Use a flathead screwdriver with a bl
ملخص المحتوى في الصفحة رقم 12
Wiring TEDS Channels The NI USB-9219 supports only Class II TEDS sensors. Connect the two TEDS lines to TEDS Data (T+) and TEDS COM (T–) and ensure that neither T+ nor T– is tied in common to any of the signal inputs (terminals 3 through 6) on the NI USB-9219. Visit ni.com/info and enter the info code rdteds for information about TEDS sensors. Grounding and Shielding Considerations You can connect ground-referenced or floating signal sources to the NI USB-9219. If you make a floating connec
ملخص المحتوى في الصفحة رقم 13
NI USB-9219 Timing Options The NI USB-9219 supports four different timing options that are optimized for different types of applications by using different ADC conversion times. High Speed is optimized for high speed at the expense of noise rejection, Best 60 Hz Rejection is optimized for rejection of 60 Hz noise, Best 50 Hz Rejection is optimized for rejection of 50 Hz noise, and High Resolution is optimized for maximum overall noise rejection and provides good rejection of 50 Hz and 60 H
ملخص المحتوى في الصفحة رقم 14
4-Wire Resistance and 4-Wire RTD Modes 4-Wire Resistance and 4-Wire RTD modes source a current, which varies based on the resistance of the load, between the EX+ and EX– terminals. The measured resistance is computed from the resulting voltage reading. These modes are not affected by lead wire resistance because a negligible amount of current flows across the HI and LO terminals due to the high input impedance of the ADC. Refer to Figure 12 for an illustration of the connections. Wire EX+
ملخص المحتوى في الصفحة رقم 15
2-Wire Resistance and Quarter-Bridge Modes In 2-Wire Resistance and Quarter-Bridge modes, connect the two ends of the resistor or gauge to the NI USB-9219 across the HI and LO terminals. These modes source a current, which varies based on the resistance of the load, between the HI and LO terminals. The resulting resistance is computed from the voltage measurement. 2-Wire Resistance and Quarter-Bridge modes do not compensate for lead wire resistance. Refer to Figure 14 for an illustration o
ملخص المحتوى في الصفحة رقم 16
Thermocouple Mode In Thermocouple mode, connect the positive end of the thermocouple to HI and the negative end of the thermocouple to LO. This mode uses the ±125 mV range of the ADC to return a voltage reading. Use shielded cables and twisted-pair wiring and ground the shielded cables. Each channel has a built-in thermistor for cold-junction compensation (CJC) calculations. For improved CJC sensor accuracy, operate the NI USB-9219 in a stable temperature environment and avoid placing heat
ملخص المحتوى في الصفحة رقم 17
Specifications The following specifications are typical for the range 0 to 60 °C unless otherwise noted. Input Characteristics Number of channels ............................... 4 analog input channels ADC resolution ...................................... 24 bits Type of ADC.......................................... Delta-sigma (with analog prefiltering) Sampling mode ...................................... Simultaneous Type of TEDS supported ....................... IEEE 1451.4 TEDS Class II (
ملخص المحتوى في الصفحة رقم 18
Overvoltage protection Terminals 1 and 2 ............................±30 V Terminals 3 through 6, across any combination ...................±60 V Input impedance Voltage and Digital In modes (±60 V, ±15 V, ±4 V)......................1 MΩ Current mode...................................< 40 Ω All other modes ...............................>1 GΩ Accuracy Gain Error Offset Error † † Mode, Range (% of Reading) (ppm of Range) Voltage, ±60 V ±0.3, ±0.4 ±20, ±50 Voltage, ±15 V ±0.3, ±0.4 ±60, ±180 Volta
ملخص المحتوى في الصفحة رقم 19
Stability Gain Drift Offset Drift (ppm of (ppm of Mode, Range Reading/°C) Range/°C) Voltage, ±60 V ±20 ±0.2 Voltage, ±15 V ±20 ±0.8 Voltage, ±4 V ±20 ±3.2 Voltage, ±1 V ±10 ±0.2 Voltage/Thermocouple, ±125 mV ±10 ±1.6 Current, ±25 mA ±15 ±0.4 4-Wire and 2-Wire Resistance, 10 kΩ ±15 ±3 4-Wire and 2-Wire Resistance, 1 kΩ ±15 ±30 4-Wire and 3-Wire RTD, Pt 1,000 ±15 ±6 4-Wire and 3-Wire RTD, Pt 100 ±15 ±60 Quarter-Bridge, 350 Ω ±15 ±120 Quarter-Bridge, 120 Ω ±15 ±240 Half-Bridge, ±500 mV/V ±3 ±20 Fu
ملخص المحتوى في الصفحة رقم 20
Input noise in ppm of Range rms Conversion Time Best Best High 60 Hz 50 Hz High Mode, Range Speed Rejection Rejection Resolution Voltage, ±60 V 7.6 1.3 1.3 0.5 Voltage, ±15 V 10.8 1.9 1.9 0.7 Voltage, ±4 V 10.8 2.7 2.7 1.3 Voltage, ±1 V 7.6 1.3 1.3 0.5 Voltage/Thermocouple, 125 mV 10.8 1.9 1.9 1.0 Current, ±25 mA 10.8 1.9 1.9 1.0 4-Wire and 2-Wire Resistance, 10 kΩ 4.1 1.3 0.8 0.3 4-Wire and 2-Wire Resistance, 1 kΩ 7.1 1.8 1.2 0.7 4-Wire and 3-Wire RTD, Pt 1,000 7.6 1.7 1.1 0.4 4-Wire and 3-Wire