ملخص المحتوى في الصفحة رقم 1
BitStorm 4800 Express Model 4821-A2
Installation Guide
March 2006
Document Part Number: 4821-A2-ZN21-30
ملخص المحتوى في الصفحة رقم 2
Zhone Technologies @Zhone Way 7001 Oakport Street Oakland, CA 94621 USA 510.777.7000 www.zhone.com info@zhone.com COPYRIGHT 2000–2005 Zhone Technologies, Inc. All rights reserved. This publication is protected by copyright law. No part of this publication may be copied, distributed, displayed, modified, transmitted, stored in a retrieval system, or translated without express written permission from Zhone Technologies, Inc. Acculink, ADSL/R, Bitstorm, Comsphere, DSL the Easy Way, Etherloop,
ملخص المحتوى في الصفحة رقم 3
End User License Agreement (Zhone and Affiliates) Restrictions. The Software may not be (a) Used on or from any system other than the System; (b) Used with more than any maximum number of subscribers stated in the documentation accompanying the Software; (c) Used so as to circumvent any technological measure included therein or provided by Zhone from time to time to control access to or limit use of the Software; (d) sublicensed, rented, leased or lent to third parties; (e) imported or expo
ملخص المحتوى في الصفحة رقم 4
U.S. Government Users. The Software is a "commercial item" as defined at 48 C.F.R. 2.101, consisting of "commercial computer software" and "commercial computer software documentation" as such terms are used in 48 C.F.R. 12.212. Under 48 C.F.R. 12.212 and 48 C.F.R. 227.7202-1 to 227.7202-4, U.S. Government Users acquire the Software only with the rights set forth therein. Third Party Licensors. This Zhone End User License Agreement may be accompanied by differing or additional provisions ap
ملخص المحتوى في الصفحة رقم 5
End User License Agreement (Zhone and Affiliates) 8 A rare phenomenon can create a voltage potential between the earth grounds of two or more buildings. If products installed in separate buildings are interconnected, the voltage potential may cause a hazardous condition. Consult a qualified electrical consultant to determine whether or not this phenomenon exists and, if necessary, implement corrective action prior to interconnecting the products. 9 In addition, if the equipment is to be use
ملخص المحتوى في الصفحة رقم 6
EMI Notices ! UNITED STATES – EMI NOTICE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful inter
ملخص المحتوى في الصفحة رقم 7
End User License Agreement (Zhone and Affiliates) Notices to Users of the Canadian Telephone Network NOTICE: This equipment meets the applicable Industry Canada Terminal Equipment Technical Specifications. This is confirmed by the registration number. The abbreviation IC before the registration number signifies that registration was performed based on a Declaration of Conformity indicating that Industry Canada technical specifications were met. It does not imply that Industry Canada approve
ملخص المحتوى في الصفحة رقم 8
8 BitStorm 4800 Express Model 4821-A2 Installation Guide 4821-A2-ZN21-30
ملخص المحتوى في الصفحة رقم 9
CONTENTS End User License Agreement (Zhone and Affiliates)........................2 Document Purpose and Intended Audience ......................................11 Document Summary .............................................................................11 Related Product Documents ................................................................12 Chapter 1- Installation .............................................................................................................13 Overview .
ملخص المحتوى في الصفحة رقم 10
Chapter 4- Configuration .......................................................................................................35 Overview ................................................................................................35 Using the CLI .......................................................................................36 Configure Management Default Gateway Address....................37 Configure Management Inband Address....................................37 Configure Manage
ملخص المحتوى في الصفحة رقم 11
ABOUT THIS GUIDE Document Purpose and Intended Audience ® This document is written for technicians who install the BitStorm 4800 Express Model 4821-A2 IP DSLAM. Document Summary Section Description Chapter 1-, Installation Describes the physical installation of the BitStorm 4800 Express into a rack. Chapter 2-, Cabling Describes how to install all cables for the BitStorm 4800 Express. Chapter 3-, LEDs Explains the meaning and usage of the front panel LEDs. Chapter 4-, Describes the minimal
ملخص المحتوى في الصفحة رقم 12
Related Product Documents Documentation for the BitStorm 4800 Express IP DSLAM is available on the World Wide Web at www.zhone.com. Document Title BitStorm 4800 Express Model 4821-A2 Command Line Interface Reference Describes the Command Line Interface (CLI) used to configure and monitor the BitStorm 4800 Express. BitStorm 4800 Express Model 4821-A2 SNMP Reference Contains the information necessary to use Simple Network Management Protocol (SNMP) to configure and monitor the BitStorm 480
ملخص المحتوى في الصفحة رقم 13
INSTALLATION Overview ® The BitStorm 4800 Express is a stackable IP DSLAM designed for installation in a Central Office (CO), multi-tenant unit (MTU), or multi-dwelling unit (MDU) environment. The BitStorm 4800 Express is interoperable with the Hotwire 6381 ADSL/R modem, a
ملخص المحتوى في الصفحة رقم 14
Installation Preparation Consider the following before installing the BitStorm 4800 Express IP DSLAM: Installation Site Your installation site should be well ventilated, clean, and free of environmental extremes. Installation Options The BitStorm 4800 Express may be: — Mounted with the included mounting brackets in a standard 19-inch (483 mm) or 23-inch (584 mm) rack (including both Bay Networks and Nortel 23-inch racks), or, with separately purchased mounting brackets, in a 21-inch (5
ملخص المحتوى في الصفحة رقم 15
Cables Required Cables Required Table 2 shows all the cables that may be required for your installation. Table 2: Cable Descriptions Connector Name Connector and Cable For Connecting . . . DSL PORTS 50-pin RJ21X Telco-type Up to 24 DSL ports per 1–24 straight connector and cable to a POTS splitter. 50-wire cable. Two cables DSL Ports 25–48 required for 48-port model. (if installed) Port 2 8-position modular plug The BitStorm 4800 10/100BaseT and 8-wire Category 5 or Express to a network. be
ملخص المحتوى في الصفحة رقم 16
Installation Unpacking the Hardware HANDLING PRECAUTIONS FOR ! STATIC-SENSITIVE DEVICES This product is designed to protect sensitive components from damage due to electrostatic discharge (ESD) during normal operation. When performing installation procedures, however, take proper static control precautions to prevent damage to equipment. If you are not sure of the proper static control precautions, contact your nearest sales or service representative. The BitStorm 4800 Express is shipped
ملخص المحتوى في الصفحة رقم 17
Mounting Configurations Mounting Configurations Three basic installation configurations are available: Rack mount – see Installing the Brackets for Rack Mounting on page 17 and Installing the BitStorm 4800 Express Into a Rack on page 19. Wall mount – see Installing the BitStorm 4800 Expr
ملخص المحتوى في الصفحة رقم 18
Installation 3 Identify six flat-head screws (for 19-inch racks) or six machine screws (for 23-inch racks) provided with the mounting brackets in the hardware kit. 4 Attach the brackets appropriate to your rack size. Tighten all screws firmly. !!"$,*.( !!"
#$%$& '()*+,- $,*.( / !!"$,*.( !!" *+('0 $,*.( 18 BitStorm 4800 Express Model 4821-A2 Installation Guide 4821-A2-ZN21-30
ملخص المحتوى في الصفحة رقم 19
Installing the BitStorm 4800 Express Into a Rack Installing the BitStorm 4800 Express Into a Rack Two types of mounting screws are provided. Use: #10-32 mounting screws for rails with threaded screw holes #12-24 mounting screws and self-retaining nuts for rails with unthreaded screw holes To install the BitStorm 4800 Express into a rack: 1 Determine where in the rack you will mount the BitStorm 4800 Express. If your rack does not have threaded screw holes, slip self-retaining nuts onto th
ملخص المحتوى في الصفحة رقم 20
3
2 Installation 3 Insert and tighten the screws in the top screw positions, then tighten the bottom screws. 20 B