ملخص المحتوى في الصفحة رقم 1
IMI CORNELIUS INC One Cornelius Place Anoka, MN 55303-6234
Telephone (800) 238-3600 Facsimile (800) 535-4231
OPERATORS MANUAL – ICE COOLED DISPENSERS
This instruction applies to all models of Drop-In and Free-Standing Ice Cooled
dispensers.
RECOMMENDED MAINTENANCE
Details of each task are listed immediately below the chart. Refer to the details by task number.
Maintenance Schedule
Task D W M Q
1. Clean all exterior surfaces O
2. Clean dispensing valv
ملخص المحتوى في الصفحة رقم 2
CAUTION: To minimize the possibility of damaging the surface of the painted tower care must be taken when choosing a cloth. The cloth must be of clean cotton with a deep nap, or equivalent. If a damp cloth is instructed to use, it must be rinsed out in clean water, the damp or the dry cloth must be manually fluffed to a softened consistency before using to wipe or polish the painted tower. D. For the painted tower, (rather than a stainless steel tower) the painted surface may be cleaned using mi
ملخص المحتوى في الصفحة رقم 3
F. Prepare two or more gallons of sanitizing solution. Pour half of the solution down the bin and drip tray drains. After the has completely drained, pour the remaining solution down the drains. G. Replace the drain strainer. H. Using a mechanical spray bottle, prepare sanitizing solution and spray the entire interior bin surfaces. Allow to air dry. 5. Sanitize Tank Systems, Post-Mix and Pre-Mix A. Remove all ice from the ice bin and melt any remaining ice with hot water. B. Remove all the quick
ملخص المحتوى في الصفحة رقم 4
F. Rinse the B-I-B disconnects in the sanitizing solution. G. Sanitizing fittings must be attached to each B-I-B disconnect. If these fittings are not available, the fittings from empty B-I-B bags can be cut from the bags and used. These fittings open the disconnect so the sanitizing solution can be drawn through the disconnect. H. Place all the B-I-B disconnects into the pail of sanitizing solution. Operate all the valves until the sani- tizing solution is flowing from the valve. I. Remove the
ملخص المحتوى في الصفحة رقم 5
DRINK DISPENSER VALVES IMI CORNELIUS INC. MASON CITY IA. DRINK DISPENSERS VALVE TYPE MANUFACTURER PORTION CONTROL MAXIMUM OPERATING PRESSURE CORNELIUS 130 psi LANCER 100psi FLOWMATIC 100psi McCANN 130psi PUSH BUTTON CORNELIUS 130psi LANCER 100psi FLOWMATIC 100psi McCANN 130psi LEVER TYPE CORNELIUS 130psi LANCER 100psi FLOWMATIC 100psi McCANN 130psi AUTOFILL LEVER CORNELIUS 130psi LANCER 100psi FLOWMATIC 100psi McCANN 130psi NON–ELECTRIC CORNELIUS 130psi LANCER 100psi PREMIX TYPE CORNELIUS 130psi
ملخص المحتوى في الصفحة رقم 6
TROUBLESHOOTING TROUBLESHOOTING Trouble Probable Cause Remedy WATER-TO-SYRUP ‘‘RATIO’’ A. Dispensing valve syrup flow A. Adjust Water-to-Syrup ‘‘Ratio’’ of TOO LOW OR TOO HIGH regulator not properly dispensed drink as instructed. adjusted. B. CO gas pressure to syrup B. Adjust syrup tanks secondary 2 tanks insufficient to push syrup CO regulator as instructed. 2 out of tank or to pump from the B-I-B container. ADJUSTMENT OF A. Dispensing valve syrup flow A. Sanitize syrup system as DISPENSING VA
ملخص المحتوى في الصفحة رقم 7
Trouble Probable Cause Remedy DISPENSED PRODUCT A. Carbonator primary CO A. Adjust carbonator primary CO 2 2 CARBONATION TOO LOW regulator out of adjustment for regulator (Reference manual existing water conditions or provided with carbonator). temperature. B. Air in carbonator tank. B. Vent air out of carbonator tank through relief valve. Actuate dispensing valve carbonated water lever to make carbonator pump cycle on. C. Water, oil, or dirt, in CO C. Remove contaminated CO . 2 2 supply. Clean
ملخص المحتوى في الصفحة رقم 8
Trouble Probable Cause Remedy DISPENSED PRODUCT A. Dispensing valve restricted A. Sanitize syrup system as PRODUCES FOAM AS IT or dirty. instructed. LEAVES DISPENSING VALVE B. Tapered nylon washer inside B. Replace nylon washer. Make sure carbonated water line swivel it is properly seated. nut connector distorted restricting carbonated water flow. C. Dirty water supply. C. Check water filter. Replace cartridge. (see NOTE) D. Warm Product - No ice in bin, D. Replenish ice, break ice up to bridged
ملخص المحتوى في الصفحة رقم 9
Trouble Probable Cause Remedy ONLY CARBONATED WATER A. Quick disconnects not secure A. Secure quick disconnects on DISPENSED on syrup tanks. syrup tanks. B. Out of syrup. B. Replenish syrup supply as instructed. C. B-I-B connectors not properly C. Properly attach the connectors. connected. D. Syrup secondary CO D. Adjust syrup tanks secondary 2 regulator not properly CO regulator as instructed. 2 adjusted. E. Inoperable dispensing valve. E. Repair dispensing valve. F. Dispensing valve syrup flow
ملخص المحتوى في الصفحة رقم 10
WARRANTY IMI Cornelius Inc. warrants that all equipment and parts are free from defects in material and workmanship un- der normal use and service. For a copy of the warranty applicable to your Cornelius product, in your country, please write, Fax or telephone the IMI Cornelius office nearest you. Please provide the equipment model num- ber and the date of purchase. IMI Cornelius Offices AUSTRALIA P.O. 210, RIVERWOOD, NSW 2210, AUSTRALIA (61) 2 533 3122 FAX (61) 2 534 2166 AUSTRIA AM