ملخص المحتوى في الصفحة رقم 1
INSTALLATION MANUAL
FOR THE
KC-SERIES
OF
SOLAR PHOTOVOLTAIC POWER MODULES
Please read this manual carefully before installing the modules.
KYOCERA CORPORATION
1. INTRODUCTION
As the world leader in development and application of high technology ceramic/silica materials, Kyocera Corporation
(KC) offers a wide range of highly efficient and reliable crystalline silicon solar photovoltaic (PV) power modules.
Kyocera began to extensively research PV technology in 1975 and commenced manufacturing oper
ملخص المحتوى في الصفحة رقم 2
corrosion. ・ The solar module frame must be attached to a support structure using ¼” or M6 stainless steel hardware in a minimum of four (4) places symmetrical on the solar module. The stainless steel hardware used for securing the module frame should secured with an applied torque of 6 foot-pounds (8 Newton-meters). ・ Module support structures that are to be used to support Kyocera Solar modules should be wind rated and approved for use by the appropriate local and civil codes prior to installa
ملخص المحتوى في الصفحة رقم 3
7. INSTALLING KC MODULES The frame of each module has 0.28” φ diameter (7 mm) mounting holes (Refer to Module Mounting Specifications). These are used to secure the modules to the supporting structure. An example of a ground mounted structure is shown in Figure 3. The four holes close to the corners of the module are most often used for attachment. Refer to the Mounting Specification Specifications for the position of these holes. Clearance between the module frame and the mounting surface may b
ملخص المحتوى في الصفحة رقم 4
C. The wire used to interconnect the solar modules may be single or two conductor, from 14 AWG (2.08 TERMINAL SCREW 2 2 mm ) up to 10 AWG (5.26 mm ) gauge stranded copper wire, in a “SUNLIGHT RESISTANT” jacket SPRING WASHER UF cable. This cable is suitable for applications CABLE where wiring is exposed to the direct rays of the sun. The maximum and minimum outer diameters CUP WASHER of the cable that may be used with the cable connector are 8 mm and 6 mm respectively (Fig. 3). D. Using a flat bl
ملخص المحتوى في الصفحة رقم 5
When a bypass diode is wired in parallel with the series string, the forced current will flow through the diode and bypass the shaded module, thereby minimizing module heating and array current losses. For 12-volt systems and higher: Each module junction box has a diagram illustrating the proper orientation of the bypass diode installed between two of the terminal screws (Figure 11, Figure 12). When the solar modules are connected as individual series strings first, and then these strings are co
ملخص المحتوى في الصفحة رقم 6
Table 2. Kyocera KC-Family Module Specifications Electrical Characteristics: Model Number KC-120-1 KC-80 KC-70 KC-60 KC-50 KC-45 KC-40 KC-35 Rated Power, Watts (Pmax) 120 80 70 60 50 45 40 35 Open circuit Voltage (Voc) 21.5 21.5 21.5 21.5 21.5 19.2 21.5 18.8 Short Circuit Current (Isc) 7.45 4.97 4.35 3.73 3.1 3.1 2.48 2.5 Voltage at Load (Vmp) 16.9 16.9 16.9 16.9 16.7 15 16.9 15 Current at Load (Imp) 7.1 4.73 4.14 3.55 3 3 2.34 2.33 Maximum System Voc 600 600 600 600 600 600 600 N/A Fa
ملخص المحتوى في الصفحة رقم 7
MODULE MOUNTING DIMENSIONS DO NOT USE DO NOT USE KYOCERA KC−SERIES MODULE MOUNTING SPECIFICATIONS