ملخص المحتوى في الصفحة رقم 1
INSTALLATION INSTRUCTIONS
PCM-MS2
Universal Flat Panel Mount
NORTH AMERICA EUROPE
3130 East Miraloma Avenue Swallow House,
Anaheim, CA 92806 USA Shilton Industrial Estate,
USA and Canada – Shilton, Coventry, England CV79JY
Phone: 800-368-9700 Phone: +44 (0) 2476 614700
Fax: 800-832-4888 Fax: +44 (0) 2476 614710
Other Locations – Phone: (001)-714-632-7100; Fax: (001)-714-632-1044
©Premier Mounts 2009
9531-000-501-04
ملخص المحتوى في الصفحة رقم 2
PCM-MS2 Table of Contents Warning Statements ........................................................................................................................................- 2 - Parts List ...........................................................................................................................................................- 3 - Installation Tools (not supplied) ..........................................................................................................
ملخص المحتوى في الصفحة رقم 3
PCM-MS2 Parts List This wall mount is shipped with all proper installation hardware and components. Make sure that none of these parts are missing and/or damaged before beginning installation. If there are parts missing and/or damaged, please stop the installation and contact Premier Mounts (800) 368-9700. Mounting Wall Plates Brackets (Qty 2) (Qty 2) PCM Wall Plate Griplates™ End Covers (Qty 6) (Qty 2) Thread Depth 5/16" X 3" Indicator Lag Bolts (Qty 1
ملخص المحتوى في الصفحة رقم 4
PCM-MS2 Hardware Pack M4 x30( Qty6) M5 x 30 ( Qty 6) M4 x25( Qty6) M5 x 25 ( Qty 6) M4 x16( Qty6) M5 x 16 ( Qty 6) M6 x45( Qty6) M8 x 70 ( Qty 4) M6 x30( Qty6) M8 x 45 ( Qty 6) M6 x 25 ( Qty 6) M8 x 30 ( Qty 6) M6 x16( Qty6) M8 x25( Qty6) M8 x16( Qty6) Universal Spacers (Qty 24) Installation Manual Page - 4 -
ملخص المحتوى في الصفحة رقم 5
PCM-MS2 Thread Depth Indicator Step 1. Insert the thread depth indicator (supplied) through the thread inserts found on the back of the flat panel to make sure the inserts measure the same full depth and mark it. Step 2. Locate the correct diameter screw for the thread insert. Compare your marking to the screws (supplied). Step 3. If your selected screw is longer than the marking on the thread depth indicator, DO NOT USE this screw. Step 4. The screw length must not bypass the marking.
ملخص المحتوى في الصفحة رقم 6
PCM-MS2 Finding the Center of the Flat Panel Display Proper installation procedure by qualified personnel as outlined in the installation instructions must be adhered to. Failure to do so could result in personal injury and possible damage to the flat panel. Invert the flat panel and place it on a soft, flat surface to prevent damage to the flat panel. Failure to do so will result in damaging the flat panel. Do not lay the flat panel on the floor without any protection to the glass.
ملخص المحتوى في الصفحة رقم 7
PCM-MS2 C Bottom of L Flat Panel Align the Mounting Bracket Mounting Brackets Center of Inverted Viewing Guide Flat Panel Center Line Step 3. Match the center of viewing guide with the center line The mounting brackets are designed with a you marked in step 1. center viewing guide on the side to indicate the center of the bracket. Griplate™ Installation Dimples Griplates™ have M4, M5 M6 and M8 hole patterns to fit the hardware that your flat panel requires. M8 EXAMPLE:
ملخص المحتوى في الصفحة رقم 8
PCM-MS2 Wall Plate End Covers Installation Step 1. Place the upper and lower wall plates on a flat surface. Step 3. Attach the wall plate end cover to the upper and lower Step 2. Align the wall plate end cover with the wall wall plates and press down firmly. When the two plate center rods (see illustration above). engage, an audible ‘snap’ will be heard. Step 4. Repeat step 3 to attach the other wall plate cover to the opposite side. Wall Stud Location 16" 16" Ste
ملخص المحتوى في الصفحة رقم 9
PCM-MS2 16" Step 5. Level the wall plate with the reference arrow pointing up Step 7. Secure the upper and lower wall plates using the to the ceiling. eight (8) 5/16" lag bolts and flat washers. Step 6. Drill eight (8) ¼" pilot holes to the marked wall. Do NOT over-tighten lag bolts when attaching the mount to the wall. Improper installation may result in personal injury or damage to property. Completed Installation Diagram Page 9 Installation Manual
ملخص المحتوى في الصفحة رقم 10
PCM-MS2 Securing the Flat Panel to the Wall Mount AT LEAST (2) PEOPLE ARE STRONGLY RECOMMENDED TO LIFT AND SECURE THE FLAT PANEL TO THE WALL PLATE. FAILURE TO DO SO COULD RESULT IN SERIOUS INJURY AND POSSIBLE DAMAGE TO THE FLAT PANEL. Step 1. Raise the flat panel with the secured mounting brackets installed and engage the top and bottom hooks from each bracket to the center rods of the Top wall plates Bottom Installation Manual Page 10
ملخص المحتوى في الصفحة رقم 11
PCM-MS2 LATERAL SHIFT Lateral Shift Adjustment Step 1. Make any lateral shift adjustment and lock it by tightening the two (2) M6 x 30mm (supplied) to the bottom of the mounting brackets. Installing the Safety Knurl Knobs Step 1. Tilt the flat panel and secure the two (2) M6 x 12 mm) safety knobs to each of the mounting brackets. Page 11 Installation Manual
ملخص المحتوى في الصفحة رقم 12
PCM-MS2 Technical Specifications All measurements are in inches(mm). Installation Manual Page 12
ملخص المحتوى في الصفحة رقم 13
PCM-MS2 Warranty PREMIER MOUNTS LIMITED LIFETIME WARRANTY What and Who is Covered by this Limited Warranty and for How Long Premier Mounts warrants this product to be free from defects in material and workmanship for the lifetime of the original owner of this product. The limited warranty is valid only for the original purchaser of the product. What Premier Mounts Will Do At the sole option of Premier Mounts, Premier Mounts will repair or replace any product or product part that is