ملخص المحتوى في الصفحة رقم 1
Total Protection Alarm System
SMARTHOME™ #7307
PA T. D410633
Patents Pending
ملخص المحتوى في الصفحة رقم 2
TABLE OF CONTENTS Your Guide to the PACKAGE CONTENTS........................................................................4 Total Protection Alarm System OVERVIEW........................................................................................5 PLANNING YOUR HOME SECURITY NEEDS.......................................6 SMARTHOME™ #7307 INSTALLATION -Control Panel................................................................................... 7 -Door/Window Sensor.......................
ملخص المحتوى في الصفحة رقم 3
PACKAGE CONTENTS OVERVIEW Everything required for installation is included with this package Congratulations! You have just purchased one of the most reliable and up-to-date wireless 1 Control Panel (SC-001) includes: security systems on the market today. Skylink is the first company to in- 1 antenna (installed) corporate the rolling code technology in a home/business security system. 1 AC adapter This innovative technology provides increased security and trouble free 1 9 volt alkaline batte
ملخص المحتوى في الصفحة رقم 4
PLANNING YOUR HOME SECURITY NEEDS INSTALLATION Before you begin to install your security system, analyze the premises to The Control Panel, door/window sensors and the motion sensor are installed determine your security needs. Consider those doors and windows which using the screws included. We have also included double sided tape, (for the are more likely to be used as points of entry by an intruder, the ones that door/window sensor and the motion sensor) to use for temporary installation are p
ملخص المحتوى في الصفحة رقم 5
INSTALLATION INSTALLATION 2. Position the magnetic switch connected to 4. Attach the unit to the wall. If hanging the the transmitter on the door/window frame. unit, insert two screws using the template provided. If screwing the back directly to 3. Position the magnet on the door beside the the wall, take the back plate right off by magnetic switch. They should be no more prying apart one hinge. Use as much than 1 cm (3/8 inch) apart. When the door/ force as needed. The plastic hinge will not wi
ملخص المحتوى في الصفحة رقم 6
INSTALLATION TESTING YOUR SYSTEM Before you learn how to use your security system, test to make sure that (Cont. : Installing the motion sensor (PS-433) the door/window sensors and the motion sensor are communicating with the Set the switch on the side to "TEST" and allow 60 seconds for the unit to warm Control Panel. up. ( when using test mode, a signal will not be sent to the Control Panel ). Set the Control Panel to CHIME MODE which will emit a subtly two tone Now walk in the area you want th
ملخص المحتوى في الصفحة رقم 7
LIGHTS AND SOUNDS STANDARD PROGRAMMING Now that the system is installed and the sensors are communicating with the Below is an explanation of the lights and sounds of the Control Panel. Control Panel, it is time to learn how to do basic programming of your security LIGHTS system. More advanced features are explained further in the manual, (see ACPWR light on System is being powered by electrical current. Advanced Programming). ACPWR light off System is not receiving any electrical power. LOBATT.
ملخص المحتوى في الصفحة رقم 8
STANDARD PROGRAMMING KEYCHAIN TRANSMITTER (4B-434) Option 2: Home Sequence - To arm your system when someone The Keychain Transmitter conveniently fits on any keychain. It allows you to remains in the premises. arm and disarm the system from a distance of approximately 100 feet from the Control Panel. The distance will depend on what is between the key- 1. Press the current MPIN [ 0 0 0 ]. chain transmitter and the Control Panel. It also has a panic button that lets 2. Press [ C ]. you remot
ملخص المحتوى في الصفحة رقم 9
KEYCHAIN TRANSMITTER (4B-434) PASSWORDS TO DISARM THE SYSTEM, OR DEACTIVATE THE SIREN USING MASTER PERSONAL IDENTIFICATION NUMBER (MPIN) THE KEYCHAIN TRANSMITTER Security access to the SC-100 is controlled by a MASTER PERSONAL IDENTIFICATION NUMBER (MPIN) or SECONDARY PERSONAL When the system is armed: IDENTIFICATION NUMBER (SPIN). All programming sequences start with Press button #3. either the MPIN or SPIN. The red light on the transmitter flashes and the Control Panel beeps twice. To Change y
ملخص المحتوى في الصفحة رقم 10
ADVANCED PROGRAMMING PASSWORDS PROGRAM SENSORS TO DIFFERENT ZONES SECONDARY PERSONAL IDENTIFICATION NUMBER (SPIN) You now have a basic understanding of how the SC-100 security system You may want to give someone limited access to the system, (baby sitter, works. In this section, (Advanced Programming), we will explain how to cleaner, repairman etc.). For this purpose the SC-100 provides you with the move sensors to different zones, how to change the alarm modes (for option of adding up to 3 sep
ملخص المحتوى في الصفحة رقم 11
ADVANCED PROGRAMMING ADVANCED PROGRAMMING To program sensors to send their signals to a different zone, you must first 3. Press [B]. clear them from communicating with their current zone. 4. Press the number key to identify which zone to add the Motion Sensor to [1, 2, 3, 4]. We recommend you program the motion sensor to zone 2. The TO CLEAR A ZONE zone light will flash for eight seconds. 1. Enter the current MPIN. 5. While the zone light is flashing, press [ * ]. 2. Press [ B ]. 6. While the zo
ملخص المحتوى في الصفحة رقم 12
ADVANCED PROGRAMMING ADVANCED PROGRAMMING 1. Enter the current MPIN. STANDARD ARMING SEQUENCES 2. Press [ A ]. Each zone can be programmed to react 5 different ways when it receives a signal from a remote sensor. 3. Press [ A ]. 1. Chime Mode - represented by the green lights You will hear a long beep. The arm light, the red and green lights in zones When only the green light is on and the Control Panel receives a 1 and the red lights in zones 3 and 4 go on. Zone 1 has the entry delay to s
ملخص المحتوى في الصفحة رقم 13
ADVANCED PROGRAMMING SUMMARY OF ARMING SEQUENCES TO CUSTOMIZE A SEQUENCE: Below is a table summarizing all the preprogrammed sequences. Sequence Zone 1 Zone 2 Zones 3 & 4 When sequence should be used Program the system to the sequence you want to alter. FOR TESTING 1. Enter the current MPIN. MPIN A # chime chime chime use for testing after installation and to test batteries, also use as 2. Press [ B ]. a subtle chime when a remote 3. Press a number key to selec
ملخص المحتوى في الصفحة رقم 14
BATTERY MAINTENANCE BATTERY MAINTENANCE The SC-100 Security System comes with 5 batteries that at some point you MOTION SENSOR BATTERY may have to replace: The Motion Sensor operates on a 9 volt alkaline battery accessible beneath a sliding panel on the bottom of the unit. All remote sensors come with the battery 1 9 volt alkaline battery for the Control Panel already installed. Disarm the Control Panel before replacing all batteries. 1 9 volt alkaline battery for the Motion Sensor When the batt
ملخص المحتوى في الصفحة رقم 15
BATTERY MAINTENANCE KEYCHAIN TRANSMITTER BATTERY The Keychain Transmitter operates on a 12 volt alkaline battery which is installed at the factory. There are two screws on the back of the transmitter that holds the case together. To replace the Keychain Transmitter battery: 1. Undo the two screws on the back of the transmitter. The back will then come off. 2. Using a small screwdriver or pen knife, pry out the old battery from one end. 3. Place the new battery in po