ملخص المحتوى في الصفحة رقم 1
®
SS30/SS3000/
SS3002 Dome
Enclosures
Installation/
Operation Manual
C428M-B (2/98)
Pelco • 3500 Pelco Way • Clovis, CA 93612-5699 USA • www.pelco.com
In North America and Canada: Tel (800) 289-9100 • FAX (800) 289-9150
International Customers: Tel (1-559) 292-1981 • FAX (1-559) 348-1120
ملخص المحتوى في الصفحة رقم 2
CONTENTS Section Page 1.0 GENERAL ..................................................................................................3 1.1 IMPORTANT SAFEGUARDS AND WARNINGS ............................... 3 2.0 DESCRIPTION ..........................................................................................4 2.1 MODELS ............................................................................................4 2.2 OPTIONS .....................................................................
ملخص المحتوى في الصفحة رقم 3
1.0 GENERAL 1.1 IMPORTANT SAFEGUARDS AND WARNINGS Prior to installation and use of this product, the following WARNINGS should be observed. 1. Installation and servicing should only be done by Qualified Service Personnel and conform to all Local codes. 2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it must not be installed where exposed to rain and moisture. 3. Only use replacement parts recommended by Pelco
ملخص المحتوى في الصفحة رقم 4
2.0 DESCRIPTION Pelco’s SS30/SS3000 series is a full-sphere, discreet surveillance enclosure de- signed to be suspended from a ceiling and to complement the interior decor of businesses, hotels, and offices. The smoked finished lower dome effectively camouflages a CTTV security/ surveillance system without compromising the quality of the video picture. An op- tional mirrored lower dome (SS3002) is available. The SS3000 Series has been engineered for ease of installation, serviceability, and rel
ملخص المحتوى في الصفحة رقم 5
3.0 INSTALLATION Save the shipping carton and plastic packing in case the unit has to be returned for credit or repair. 3.1 CONDUCTOR AND CABLE REQUIREMENTS Before installing the pan and tilt, determine the conductor requirements and length of cable you will need to run based on the following: Conductor requirements for the pan and tilt are as listed below, plus coax cable: Pan/Tilt Lens Cam AC PT280-24P/PT280-24SL 5+ grnd 4 2 PT280-24P/PP 9+ grnd 8 2 PT280-24SL/PP 10+ grnd 8 2 (Camera power,
ملخص المحتوى في الصفحة رقم 6
Cable distances should not exceed the distances specified in Section 3.1. The fol- lowing are some recommended common installation practices. 1. Always use jacketed stranded multi-conductor interconnecting cable between the control and the pan/tilt, with additional conductors than needed for future servicing and/or additions. 2. Always use color-coded conductors for ease of wiring and to identify functions at a later date. 3. Keep a wiring diagram with the system for later use and reference. QTY
ملخص المحتوى في الصفحة رقم 7
3.3 CONNECTOR ASSEMBLY Installation and/or testing will require you to assemble the connector parts pro- vided. Fabricate the interconnecting cable according to the following steps (refer- ence Figure 2). 1. Slide part A of the cable clamp (item 1) over the end of the cable (item 1, part C) with the threaded end of the cable clamp facing the connector (item 5). 2. If the cable has a diameter less than 1/2 inch (1.3 cm), slide the rubber boot (item 2) over the end of the cable and pull through t
ملخص المحتوى في الصفحة رقم 8
3.4 MOUNTING The SS3000 enclosure is designed to be suspended from a suitable length of 1-1/2" pipe threaded at both ends. This pipe can be interfaced to either a Pelco MRWA wall adapter, MRCA ceiling adapter, or coupled to a longer length of pipe (see Figure 3). Figure 3. Mounting Configurations 8 PELCO Manual C428M-B (2/98)
ملخص المحتوى في الصفحة رقم 9
3.4.1 Ceiling/Wall Mounting NOTE: The “Schneider” ring referred 1. Select an appropriate length of 1-1/2" NPT pipe for the mount you have se- lected. Once the mount is installed, insert and tighten the pipe to approxi- to in these instructions is a 10-inch mately 30 ft lb, then tighten the 8-32 screw in the pipe nut to lock the pipe black aluminum ring designed to fit threads. Slide the black 10"OD “Schneider” ring over the pipe and then slide around the square portion of the up- the upper dom
ملخص المحتوى في الصفحة رقم 10
9. Turn the system on and rotate the pan/tilt. Check for cable interference. Tilt the CAUTION: The lower camera up and down and check for clearance of all moving parts. dome will shatter if dropped. Always operate 10. After all tests have been done and the system is functioning properly, attach with the safety chain at- the safety chain to the upper dome with the fasteners provided. Install the tached. Do not rotate pan/ lower dome, being careful to align the viewing window. tilt by hand. Rotat
ملخص المحتوى في الصفحة رقم 11
3.5 ADJUSTMENTS CAUTION: Do not at- To adjust the pan/tilt limits, perform the following steps. Refer to Figure 6 for limit stop locations. tempt to adjust limit stops when pan/tilt is in opera- 1. Factory pan limits are set to 0-355° and tilt limits at ±45°. Pan to the right using tion. Damage to the equip- the joystick control until the desired RIGHT pan limit is reached. ment can result. Also, do not operate equipment 2. Adjust the pan limit stop until the actuator clicks. Lock the limit in
ملخص المحتوى في الصفحة رقم 12
4.0 MAINTENANCE Clean the acrylic lower dome as necessary to maintain a clear picture. Be careful not to scratch the surfaces of the dome. Exterior Surface - Clean the dome's exterior surface with a nonabrasive cleaning cloth and cleaning agent that is safe for acrylic plastic. Either liquid or spray cleaner/ wax suitable for fine furniture is acceptable. Interior Surface (Except Chrome) - Clean the same as the exterior surface. Interior Surface (Chrome) - The inside surface of a chrome dome is
ملخص المحتوى في الصفحة رقم 13
5.0 MECHANICAL PARTS LIST Table A. SS3000 Exploded Assembly Diagram (Corresponds to Figure 5) Item No. Quantity Description Part Number 11 Dome, upper SS300010000 21 Dome, lower, smoked (SS30, SS3000) SS300010001* Dome, lower, chrome (SS3002) SS331100* 31 Bracket, upper drive (SS3000/SS3002) SS30004000COMP 41 Bracket, mounting (hanging weld assy) SS300031001WA 51 Bracket, lower (SS3000/SS3002) PM200C4000COMP 61 Pipe, mounting SS34002COMP 7— Not used — 8— Not used — 916Velcro, black, 5/8" wide
ملخص المحتوى في الصفحة رقم 14
6.0 SPECIFICATIONS ELECTRICAL Input voltage: 24 VAC required for pan/tilt Power Requirements Running Starting Pan: .31 amp (7.5 vA) .47 amp (11.2 vA) Tilt: .38 amp (9.2 vA) .56 amp (13.5 vA) Connectors Pan/Tilt: AMP CPC type (mate supplied) Lens: Hirschmann MAB6100 Video: BNC Camera Power: Spade lugs Motors: Two-phase induction type, instantaneous reversing Limit Switches: 5 amp, external adjustment Conductor Requirements: See Section 3.1 MECHANICAL (for detailed specifications refer to PT280 s
ملخص المحتوى في الصفحة رقم 15
GENERAL Construction: Upper dome: Black, U.L. 94HB rated ABS plastic Lower dome: Acrylic hemisphere with distortion free viewing window with light attenuation factor of 1 f-stop (SS30/SS3000) or mirrored lower dome with 2 f-stop (SS3002). Rotates with pan and tilt, camera, and lens Environment: Indoor; 32° to 120°F (0° to 48.89°C) Unit Weight: 6 lb (2.72 kg) approximate Dimensions: See Figure 7 (Design and product specifications subject to change without notice.) This equipment contains electric
ملخص المحتوى في الصفحة رقم 16
7.0 WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on FT/FR8000 Series fiber optic products. ® • Three years on Genex Series products (multiplexers, server, and keyboard). ® • Three years on Camclosure and fixed camera models, except the CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, M