1 Description
Terminal Narrow Antenna Storage Manual Set-Up Buttons Wire Opening Knockout Opening Tab
Block
(inside the cover)
Wire Passage Hole Planar Antenna Lateral and Angle Front Cover LED
Adj. For Antenna
NOTE: For mounting heights between 10’ and 16’, use BEA model 10EAGLEHM (high mount).
2 Technical Specifications
DESCRIPTION SPECIFICATION
Frequency: 24.125 GHz
Supply voltage:
12 to 24 V AC: ± 10%:
12 to 24 V
ملخص المحتوى في الصفحة رقم 2
3 Installation Tips 1 The sensor must not have The sensor must be firmly The sensor must not be The sensor must not have any fluorescent lighting in fastened to prevent placed directly behind a any object likely to move its sensing field. vibration. panel or any kind of or vibrate in its sensing material. field. Safety Precautions 2 • Shut off all power going to the header before attempting any wiring procedures. • Maintain a clean
ملخص المحتوى في الصفحة رقم 3
Mechanical Installation 3 Opening the sensor From behind, before installation From the front, after installation Mounting the sensor or Paste the template at desired Insert screws but do not screw Optional cable routing: location. them fully in. Notch the cover as shown in the picture. Drill as instructed. Pass the cable where indicated. Electrical Installation 4 Terminal Connection 1 (Red) 12 to 24 VAC / D
ملخص المحتوى في الصفحة رقم 4
Mechanical Adjustments 5 A. THE WIDTH OF THE SENSING FIELD IS DETERMINED BY THE CHOICE OF THE PLANAR ANTENNA (OPTION) 6.4’ 3.2’ 0 3.2’ 6.4’ 0 3.2’ 6.4’ Wide sensing field: Narrow sensing field: 3-element antenna 6-element antenna 9.6’ 3-Element 6-Element Antenna Antenna SENSING FIELDS ACCORDING TO THE TYPE OF ANTENNA The sensing fields above correspond to the following adjustments: vertical angle of the antenna: 30°
ملخص المحتوى في الصفحة رقم 5
6.4’ 3.2’ 0 3.2’ 6.4’ 3-Element Antenna 70º 6-Element Antenna For ceiling mounting, the vertical tilt angle of SENSING FIELDS – CEILING MOUNT the antenna must be set at the maximum The sensing fields above correspond to position of 70-75° and the spherical part of the following adjustments: the sensor must be oriented in the opposite Vertical angle of antenna: 70º direction to the door. Sensitivity: 9 Mounting height: 7’ C. THE LATERA
ملخص المحتوى في الصفحة رقم 6
Programming Guide 6 The Eagle is equipped with a Motion Tracking Feature (MTF). The MTF is available when the Eagle is used in the uni- directional mode. The Eagle is factory preset with the MTF ON. MTF is recommended for use in short vestibule areas to help reduce unwanted door hold-open time. Refer to the Programming Guide to alter this setting. BEA recommends keeping the MTF enabled for all applications. The detection capabilities perform as follows: BI-DIRECTIONAL MODE: •
ملخص المحتوى في الصفحة رقم 7
Sensitivity Relay Hold Time Relay hold time refers to the hold time on the 0 = Minimum Sensitivity output relay of the Eagle. Values range from 0 to 9 = Maximum Sensitivity 9. Default: 8 0 = .5 sec. 1 = 1 sec through 9 = 9 sec in 1 second intervals Detection Mode Default: 0 Detection mode offers 3 different levels of detection: Immunity 1 = Bi-Directional Immunity helps to reduce the chance of 2 = Uni-Directional unwan
ملخص المحتوى في الصفحة رقم 8
4 Troubleshooting SYMPTOMS PROBABLE CAUSE CORRECTIVE ACTION The door will not open and no red The sensor power is off. Check the wiring and power supply. LED lights up. The door control is set to level 3. Set door control to automatic mode (level 1). The door opens and closes The sensor “sees” the door moving Increase the tilt angle and/or reduce the sensitivity constantly. and/or increase the immunity. When closing the door creates vibrations picked Ensure the sensor is correc