ملخص المحتوى في الصفحة رقم 1
#
®
42390
SUMMIT
SILVER A - SILVER D - GOLD D BUILT-IN LP TANK ENCLOSURE KIT
®
Summit Built-In LP Tank Enclosure Kit
(Model #: 21287)
THESE ACCESSORIES MAY BE PURCHASED SEPARATELY.
YOU MUST READ THIS OWNERS GUIDE
WARNING: Follow all leak-check
BEFORE OPERATING YOUR GAS GRILL
procedures carefully in this manual prior
to barbecue operation. Do this even if the
barbecue was dealer-assembled.
DANGER
If you smell gas:
1. Shut off gas to the appliance.
NOTICE TO INSTALLER: These instruc
ملخص المحتوى في الصفحة رقم 2
2 DANGERS & WARNINGS DANGER Failure to follow the Dangers, Warnings and Cautions contained in this Owner’s Manual may result in serious bodily injury or death, or in a fi re or an explosion causing damage to property. WARNINGS Do not store a spare or disconnected liquid propane cylinder under or near the barbecue. Improper assembly may be dangerous. Please carefully follow the assembly instructions in this manual. ® Do not operate the Weber gas barbecue if there is a gas leak present.
ملخص المحتوى في الصفحة رقم 3
3 WARRANTY OPERATING ® when assembled and operated in accordance with the printed instructions WARNING: Only use the Weber Tank Enclosure accompanying it. Kit outdoors in a well-ventilated area. Do not use in Weber may require reasonable proof of your date of purchase. THEREFORE, a garage, building, breezeway or any other enclosed YOU SHOULD RETAIN YOUR SALES SLIP OR INVOICE. area. This Limited Warranty shall be limited to the repair or replacement of parts that ® prove defective under n
ملخص المحتوى في الصفحة رقم 4
4 ASSEMBLY 3). The minimum size of the ventilation hole (s) should not be less TYPICAL 20 LP PROPANE GAS SUPPLY INSTALLATION ® than 1/4 inch. We strongly recommend that you use the Summit Built-In Tank Cabinet 4). The ventilation openings in the sidewalls should not allow (#21280) for installations using a 20 lb LP cylinder, mounted remotely in an venting into the empty or “hollow” area of the “island”. If a “island” structure. ® gas leak should occur or the LP cylinder should vent in the
ملخص المحتوى في الصفحة رقم 5
Any Surface 24 inches (60.96 cm) 5 ASSEMBLY LOCATING YOUR LP TANK ENCLOSURE KIT DANGER When determining a suitable location for your LP Tank Enclosure Kit Use of any other hose and regulator assembly could installation, give attention to concerns such as proximity to traffi c paths, and keeping any gas supply lines as short as possible. Never locate the be dangerous, and may not provide adequate gas ® ® Summit LP Tank Enclosure Kit in a garage, breezeway, shed, under an un- supply to the Sum
ملخص المحتوى في الصفحة رقم 6
6 ASSEMBLY PARTS LIST 1 Hose and regulator - 1 4 Tank stand - 1 8 4 Tank stand base - 1 2 Tank Scale - 1 1/4-20 nut - 6 2 Nylon washer - 12 4 1/4-20 x 1/2" bolt - 6 2 Cylinder glide - 2 2 1/2" Flare Gasket - 2 3/8" Flare Gasket - 2
ملخص المحتوى في الصفحة رقم 7
7 ASSEMBLY MOUNTING THE LP TANK BRACKET Mount the LP tank bracket to the right hand side of the enclosure opening using non corrosive hardware. Mounting holes are provided on the sides and bottom of your LP tank bracket. Be sure to mount the bracket securley to the enclosure before use. MOUNTING HARDWARE NOT INCLUDED. 3 MOUNTING THE LP HOSE AND REGULATOR Securley mount the hose and regulator bracket to the top of the built-in tank enclosure using non corrosive hardware. MOUNTING HARDWARE NOT IN
ملخص المحتوى في الصفحة رقم 8
8 GAS INSTRUCTIONS top of CONNECT GAS SUPPLY box A 58 inch corrugated gas line is supplied with the grill. This line needs to pass through the gas inlet opening to the main gas supply. Corrugated Gas Line to Manifold 1) Connect the corrugated gas line to the manifold located on the right hand side of grill under the control panel. Note: Leave an access in the “island” structure for 90º gas supply and regulator service not inside the grill fitting ® structure. Weber has a gas line and regu
ملخص المحتوى في الصفحة رقم 9
9 GAS INSTRUCTIONS Some of the tanks have differing top collar assembles. (The top collar is the IMPORTANT LP CYLINDER INFORMATION metal protective ring around the valve.) One series of tanks mount with the Failure to follow these DANGER statements exactly may result in a fi re valve facing front. The other tanks mount with the valve facing away from causing death or serious injury. the fuel scale. These types of tanks are illustrated below. You will need: LP cylinder, a soap and water so
ملخص المحتوى في الصفحة رقم 10
10 GAS INSTRUCTIONS 6) Turn on the cylinder valve. WARNING: You should check for gas leaks every 7) Check for leaks by wetting the fi tting with the soap and water solution time you disconnect and reconnect a gas fi tting. and watching for bubbles. If bubbles form, or if a bubble grows, there is Note - All factory-made connections have been thoroughly checked for a leak. gas leaks. The burners have been fl ame-tested. As a safety precaution If there is a leak, turn off the gas and tighten t
ملخص المحتوى في الصفحة رقم 11
11 GAS INSTRUCTIONS REFILLING THE LIQUID PROPANE CYLINDER SAFE HANDLING TIPS FOR LIQUID PROPANE GAS We recommend that you refi ll the LP cylinder before it is completely empty. CYLINDERS Removal of the LP cylinder Liquid Propane (LP) gas is a petroleum product as are gasoline and 1) Close cylinder valve (turn clockwise). natural gas. LP gas is a gas at regular temperatures and pressures. 2) Unscrew regulator coupling by turning counterclockwise, by hand only. Under moderate pressure, inside
ملخص المحتوى في الصفحة رقم 12
GAS INSTRUCTIONS If you have questions about spare LP cylinders contact (1) Customer Service at 1-800-446-1071. All LP tank supply systems must include a collar to protect the cylinder valve. The LP cylinder must be a 20-lb. size (18 1/4 inches high, 12 1/4 inches DOT 4BA240 in diameter). The cylinder should be constructed and marked in accordance with 00/02 the Specifi cations for LP - Gas Cylinders of the U.S. Department of Transportation (D.O.T.) or the National Standard of Canada,