KE-265
Keyless Entry Access Control System
Installation and Operations Manual
ملخص المحتوى في الصفحة رقم 2
Table of Contents ESSEX ELECTRONICS, INC. INTRODUCTION.......................................................................................2 KE-265 Series OVERVIEW..............................................................................................2 SYSTEM SPECIFICATIONS ........................................................................2 All rights reserved. No part of this documentation may be INPUT REQUIREMENTS........................................................
ملخص المحتوى في الصفحة رقم 3
Introduction Input Requirements The KE-265 accepts 12 to 24 volts AC/DC. An optional Overview battery charging module and rechargeable Gel Cells are The KE-265 is an easy to program, easy to use, stand-alone available to keep the system operational for up to 24 hours ® Keyless Entry system with features suitable for basic access during a power interruption. System current draw (maximum): control requirements. Providing either a voltage output or dry Standby: 10mA at 12 volt
ملخص المحتوى في الصفحة رقم 4
Keypad Options Preparing for Installation All Essex Keypads are designed to perform reliably in even the most extreme environmental conditions. Operating System Components temperatures can range from -40 °C to +70 °C (-40 °F to 160 °F). There are four primary components to be installed: The KE-265 is compatible with any of the following Keypad styles/configurations: 1. The Keypad should be mounted on the wall adjacent to the door. It should be on the same side as the door st
ملخص المحتوى في الصفحة رقم 5
6. Do NOT mount Keypad at this time. The Installation Procedure 7. Proceed to Install the Wiring Cable. Required Tools Mounting Instructions 12 Pad 3x4: KP-34S, KP-34B or KP-34K You will need the following tools: The 3x4 keypad is designed to mount to a single gang • Medium sized, Phillips head • 7/8” or 1” (25mm) drill bit switchbox or on a wall, pedestal or any flat surface of at least 3 screwdriver • 1/2” (16mm) drill bit ½ by 5 ¼”. The composition of the mounting surface will
ملخص المحتوى في الصفحة رقم 6
Note: If connecting DC, make the connections to Install the Wiring Cable “DC IN/OUT” instead of “12-24V AC/DC IN”. Make 1. Drill a ½” hole in the inside wall or ceiling where you want sure the polarity is correct. the cable to come through. 2. Pull the cable through the hole so the connector end goes ⊗ IMPORTANT: The “EARTH” screw terminal on to the keypad. Route it so there is minimal cable at the Terminal Strip “A” should be connected to a true earth keypad. ground for prope
ملخص المحتوى في الصفحة رقم 7
System Hardware Setup The Factory Default Settings are shown here: Remote By-Pass 1. All User Unlock Authorization Factory Default Settings is configured for Relay #1. In some cases, it may be necessary to control the door from a (Master Code and Users 1,2 remote area such as a security station or reception desk. The and Users 3,4,5). KE-265 provides for a Remote By-Pass (Exit Switch) or Keypad override. This can be accomplished by connecting a 2. No Code is set for Latc
ملخص المحتوى في الصفحة رقم 8
Latching Authorization th nd Ex: Latching Authorization Placing jumpers across the 4 2 Door Operation th and 5 set of pins (1,2 LATCH The KE-265 has been Ex: 2 Door Configuration or 3,4,5 LATCH) determines designed to provide 2 door which relay (if any) each User operation with one or more Group is authorized to Keypads. With this manually latch. configuration, certain codes will activate Relay #1 and How to Latch certain codes will activate When a valid code is Relay
ملخص المحتوى في الصفحة رقم 9
System Programming Programming the Master Code To Program/Change the Master Code: Overview of System Code Programming 1. Select a 3 to 8 digit code that will be used for the There are TWO levels of codes for the KE-265 system. Master Code. 1. The Master Code (used to open the door and for ___ ___ ___ ___ ___ ___ ___ ___ programming User Codes) 2. Locate the Control Module, remove the cover and 2. User Codes (used by personnel to open the door) locate the “PROGRAM” switch o
ملخص المحتوى في الصفحة رقم 10
Programming User Codes “5’s” (for every five second increment) that equal your To Program a New User Code or Change an Existing User desired Door Open Time. Each valid key press (a “1” or Code: a “5”) will generate a double beep. (Do not let more 1. Choose a new 3 to 8 digit code that will be used for this than five seconds elapse between entries or the User Code. ___ ___ ___ ___ ___ ___ ___ ___ system will reset!!!) 2. Decide which User Location to place this User Code Ex
ملخص المحتوى في الصفحة رقم 11
Troubleshooting Remember that all six codes have to be different These are a few troubleshooting suggestions to help assist with from each. It is also important not to let more than any problems you may experience. If the problem continues or is 5 seconds elapse between button presses or the not answered here, please call Essex technical support at (800) system will reset and you will have to start over. KEYLESS (800) 539-5377. You can also visit Essex anytime at keyless.com o
ملخص المحتوى في الصفحة رقم 12
Keypad beeps all by itself 5 YEAR LIMITED WARRANTY Effective Date 3/17/03 Constant Beeping - If the beep is consistently every 5 seconds, put a .1uf 16v (or higher) ceramic capacitor Essex Electronics, Incorporated warrants that at the time of original purchase ® from Essex Electronics, Incorporated, the KEYLESS ENTRY Coded Access across wires 3 & 10 (black, violet) on terminal strip “A”. System or KTP Series keypad will be free from defects in workmanship and Random Beeping - Chec
ملخص المحتوى في الصفحة رقم 13
Appendix A – Circuit Board Layout Upon receipt of such notification, Essex Electronics, Incorporated will determine whether to repair or replace. We also reserve the right to have our representative make any inspection or repairs, or furnish replacements. DISCLAIMER OF WARRANTIES: LIMITATION OF BUYER’S REMEDIES EXCEPT FOR THE REPAIR OR REPLACEMENT AT SELLER’S OPTION WHICH IS EXPRESSLY SET FORTH ABOVE, ESSEX ELECTRONICS, INCORPORATED EXTENDS NO WARRANTY OF ANY KIND, EXPRESS OR IMPLI
ملخص المحتوى في الصفحة رقم 14
Appendix B- Typical Wiring Diagrams Notes Note: Some low current strikes or relays will cause relay chatter due to inductive kickback. Attach MOV across strike or relay to eliminate chatter. Master Code ___ ___ ___ ___ ___ ___ ___ ___ Username ________________ Fail Secure Lock Fail Safe Lock User Code 1 ___ ___ ___ ___ ___ ___ ___ ___ Username ________________ Controlled by KE-265 Controlled by KE-265 7 7 User Code 2 ___ ___ ___ ___ __