ملخص المحتوى في الصفحة رقم 1
FPD1000-HP SERIES
HIGH PRESSURE
Positive Displacement Flowmeters
ملخص المحتوى في الصفحة رقم 2
ملخص المحتوى في الصفحة رقم 3
V cc 12 3 To the owner: INSTALLATION Thank you for purchasing an OMEGA FPD Series Flowmeter. Please take a few min- 1. Use thread sealant on all pipe threads. utes to read through the manual before in- 2. Ensure the meter is installed so that stalling and operating your meter. If you rotor shafts are always in a horizontal have any problems with the meter, refer to plane (See Figure 1). Flow is bi-direc- the Maintenance and Troubleshooting sec- tional. tions of the manual. This manual contains c
ملخص المحتوى في الصفحة رقم 4
12 Reed Relay Specifications Reassembly: •Two wire SPST N/O. 1. Replace rotors into the meter body. The rotors should be at 90 degrees to each •Switching voltage 150 VDC; maximum other. current 0.25 Amps. 2. Lightly rotate the rotors by hand. They •Rating 3 watts. must rotate freely. •Duty cycle 20% ON, 80% OFF. 3. Install O-ring. 4. Replace the meter cap and tighten the Figure 3 eight screws uniformly to 35Nm (25 Ft. Lbs.). 5. Replace the pulser cap and tighten the four screws. Reed Switch Wiri
ملخص المحتوى في الصفحة رقم 5
TROUBLESHOOTING Symptom Probable Cause Corrective Action FLUID WILL NOT 1. Foreign matter blocking Dismantle meter, clean rotors. Strainer must FLOW THROUGH rotors be fitted in-line. THE METER 2. Line strainer blocked Clean strainer. 3. Damaged rotors Replace rotors. Strainer must be fitted in-line. 4. Meter connections over- Re-adjust connections. tightened REDUCED FLOW 1. Line strainer partially Clean strainer. THROUGH THE blocked METER 2. Fluid is too viscous Maximum viscosity 1000 centipoise
ملخص المحتوى في الصفحة رقم 6
DISPLAY PARTS LISTING Model: FPD1202-HP 3 4 9 TERMINAL BLOCK 10 6 2 8 7 1 u = Recommended Spare Parts to stock. Bold Text = Indicates Stainless Steel model parts. Item Rec. Part or Set No. Qty. Parts (Order from this column only) Part Description 11 MS1NS Meter Body Assembly NPT 28 u MS367S Bolt Set - Socket Head 31 MS170H Pulser Cap (BSP) 31 MS170HN Pulser Cap (NPT) 44uMS115S Bolt Set - Socket Head 61 MS3HES Meter Cap & Hall Effect Assembly * 61 MS3HPS Meter Cap & Reed Switch
ملخص المحتوى في الصفحة رقم 7
SPECIFICATIONS Pulse Meter Models Flow Ranges (LPM or GPM) Above 5 centipoise 2 to 100 / 0.53 to 26.4 Below 5 centipoise 5 to 100 / 1.32 to 26.4 Accuracy of Reading ± 1% Maximum Viscosity 1000 Centipoise Maximum Operating Pressure 55160 kPa / 8000 PSI / 551 Bar Maximum Operating Temperature 120°C / 248°F Pulse Type Hall Effect Sensor / Reed Switch Pulses per Litre/Gallons 1000 / 3785 Meter Dimensions 86mm Dia. / 3.4” Dia. (Meter Body) 83mm / 3.25” (Port Fac
ملخص المحتوى في الصفحة رقم 8
DISPLAY PARTS LISTING Model: FPD1203-HP 3 4 9 TERMINAL BLOCK 10 6 2 8 7 1 u = Recommended Spare Parts to stock. Bold Text = Indicates Stainless Steel model parts. Item Rec. Part or Set No. Qty. Parts (Order from this column only) Part Description 11 MS2NS Meter Body Assembly NPT 28 u MS367S Bolt Set - Socket Head 31 MS170H Pulser Cap (BSP) 31 MS170HN Pulser Cap (NPT) 44uMS115S Bolt Set - Socket Head 61 MS3HES Meter Cap & Hall Effect Assembly * 61 MS3HPS Meter Cap & Reed Switch
ملخص المحتوى في الصفحة رقم 9
SPECIFICATIONS Pulse Meter Models Flow Ranges (LPM or GPM) Above 5 centipoise 15 to 500 / 4.0 to 132 Below 5 centipoise 25 to 500 / 6.0 to 132 Accuracy of Reading ± 1% Maximum Viscosity 1000 Centipoise * Maximum Operating Pressure 55160 kPa / 8000 PSI / 551 Bar Maximum Operating Temperature 120°C / 248°F Pulse Type Hall Effect Sensor / Reed Switch Pulses per Litre/Gallons 400 / 1514 Meter Dimensions 86mm Dia. / 3.4” Dia. (Meter Body) 83mm / 3.25” (Port Face
ملخص المحتوى في الصفحة رقم 10
ملخص المحتوى في الصفحة رقم 11
ملخص المحتوى في الصفحة رقم 12
M-4125 / 0405