ملخص المحتوى في الصفحة رقم 1
External Control Manual
RS-232C Configuration
(for PDP-614MX and PDP-424MV)
Version 1.0
Dec 2005
ملخص المحتوى في الصفحة رقم 2
PDP-614MX External Control Manual Application These specifications are applicable to plasma monitors and communications control from external equipment. Connections Connections should be made as described below. External equipment plasma monitor e.g., Personal computer 1) Connector on the plasma monitor side: EXTERNAL CONTROL connector. Type of connector: D-Sub 9-pin male No. Pin Name 1 No Connection 2 RXD (Receive data) 3 TXD (Transmit data) 4 DTR (DTE side r
ملخص المحتوى في الصفحة رقم 3
PDP-614MX External Control Manual 2) Connector on the external equipment side: Serial port (RS-232C) connector. See the specifications of the equipment that is to be connected for the type of connector and the pin assignment. 3) Wiring Use a crossed (reverse) cable. Wire the cable so that each pair of data lines cross between the two devices. These data line pairs are RXD (Receive data) and TXD (Transmit data), DTR (DTE side ready) and DSR (DCE side ready), and RTS (Ready to send) and
ملخص المحتوى في الصفحة رقم 4
PDP-614MX External Control Manual Communication Format 8bit 8bit 8bit 8bit 8bit 8bit 8bit 8bit Command 1 Unit ID 1 Unit ID 2 Command 2 Data length Data Check sum Command1 Command 1, along with command 2, is a number used to distinguish each command. When making it operate using ID, bit1 and bit0 are set up as follows. Bit1,Bit0 Unit ID distinction bit 11B :Usually, a form (with no ID) 10B :Usually, a form (with no ID) 01B :Set ID 00B :Video wall ID In the case of AC
ملخص المحتوى في الصفحة رقم 5
PDP-614MX External Control Manual the lower order 8 bits of one frame of sent or received data comprising the sum total of Command 1, Unit ID 1 and 2, Command 2, Data Length, and Data. Check Sum Example DFH 80H 60H 47H 01H 01H 08H Command1 Unit ID1 Unit ID2 Command2 Data Length Data Check Sum Total 208H 2) Error Processing • When the communication interval is vacant for more than 4 ms, thereafter a received Command 1 will be recogniz
ملخص المحتوى في الصفحة رقم 6
PDP-614MX External Control Manual The control method of the set by Set ID When controlling two or more sets of plasma monitors, if the command using Set ID is used, it will become controllable individually. The example of the POWER ON command to the plasma monitor which set ID as "5" is shown below. It is not based on ID but is the POWER ON command to all sets. 9F 80 60 4E 00 CD In ID= "5", the value of ID-1=4 is set up. 9D 84 60 4E 00 CF The example of a change in t
ملخص المحتوى في الصفحة رقم 7
PDP-614MX External Control Manual Command Reference List CMD1 CMD2 LEN 01 Power ON 9FH 4EH 00H 02 Power OFF 9FH 4FH 00H 03 Input Switch Change DFH 47H 01H 04 VOLUME Gain Data DFH 7FH 03H 05 AUDIO Mute ON 9FH 3EH 00H 06 AUDIO Mute OFF 9FH 3FH 00H 07 CONTRAST Gain Data DFH 7FH 03H 08 BRIGHT Gain Data DFH 7FH 03H 09 SHARPNESS Gain Data DFH 7FH 03H 10 Color Gain Data DFH 7FH 03H 11 TINT Gain Data DFH 7FH 03H 12 AV SELECTION Select DFH 0AH 01H 13 COLO
ملخص المحتوى في الصفحة رقم 8
PDP-614MX External Control Manual 29 OSM Select DFH 58H 01H 35 INVESE Set DFH C7H 03H 51 TIMER SWITCH DFH 02H 01H 54 TIMER PROGRAM DFH 30H 08H SETTING 55 PRESENT TIME SETTING DFH 31H 03H 56 MULTI MODE Select DFH 03H 03H 57 MULTI MODE Request 1FH 3BH 00H 58 AUTO ID SET START 5FH F0H 01H 59 PLE LINK DFH F1H 03H 60 VIDEO WALL SETTING DFH F3H 02H 61 POWER DELAY ON DFH F2H 01H (DIVIDER setting : 1/4/9) 62 POWER DELAY ON DFH F6H 01H (DIVIDER setting : 16/25) 65 ORBITTER SE
ملخص المحتوى في الصفحة رقم 9
PDP-614MX External Control Manual 01. Power ON Function The external control equipment switches on the power of the plasma monitor. Transmission Data 9FH 80H 60H 4EH 00H CKS ACK The plasma monitor returns the following ACK when the power is switched on. 3FH 60H 80H 4EH 00H CKS NOTE: Do not set the Power ON or Power OFF command continuously. 02. Power OFF Function The external control equipment switches off the power of the plasma monitor. Transmission Data 9FH
ملخص المحتوى في الصفحة رقم 10
PDP-614MX External Control Manual 03. Input Switch Change Function The external control equipment switches the input of the plasma monitor. Transmission Data DFH 80H 60H 47H 01H DATA00 CKS DATA00 : Input Select 01H : Video1 02H : Video2 03H : Video3 05H : COMPNT1 06H : COMPNT2 07H : PC1DSUB 08H : PC2-BNC 0CH : PC3-DVI ACK The plasma monitor returns the following ACK when the input is switched. 3FH 60H 80H 47H 00H CKS 10
ملخص المحتوى في الصفحة رقم 11
PDP-614MX External Control Manual 04. VOLUME Gain Data Function The external control equipment changes the VOLUME gain data of the plasma monitor. Transmission Data DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS DATA00: USER SOUND Gain Flag 05H DATA01: VOLUME Gain Flag 01H DATA02: VOLUME Gain 00H: Step0 : 0AH: Step10 (Default) : 2AH: Step42 ACK 7FH 60H 80H 7FH 02H DATA00 DATA01 CKS DATA00: USER SOUND Gain Flag 05H DATA01: VOLUME Gain F
ملخص المحتوى في الصفحة رقم 12
PDP-614MX External Control Manual 07. CONTRAST Gain Data Function The external control equipment changes the CONTRAST gain data of the plasma c Transmission Data DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS DATA00 : USER PICTURE Gain Flag 01H DATA01 : CONTRAST Gain Flag 07H DATA02 : CONTRAST Gain CCH : -52 : FFH : -01 00H : 0 01H : +01 : 14H : +20 ACK 7FH 60H 80H 7FH 02H DATA00 DATA01 CKS DATA00: USER PICTURE Gain Flag 01H
ملخص المحتوى في الصفحة رقم 13
PDP-614MX External Control Manual 01H : +01 : 10H : +16 Only when a RGB signal is connected DATA02 : SHARPNESS Gain 01H : 1 02H : 2 03H : 3 04H : 4 ACK 7FH 60H 80H 7FH 02H DATA00 DATA01 CKS DATA00 : USER PICTURE Gain Flag 01H DATA01 : SHARPNESS Gain Flag 06H 13
ملخص المحتوى في الصفحة رقم 14
PDP-614MX External Control Manual 10. COLOR Gain Data Function The external control equipment changes the COLOR gain data of the plasma monitor. Transmission Data DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS DATA00 : USER PICTURE Gain Flag 01H DATA01 : COLOR Gain Flag 04H DATA02 : COLOR Gain E0H : -32 : FFH : -01 00H : 0 01H : +01 : 20H : +32 * COLOR Gain is from -22 (EAH) to +22 (16H) only during video. ACK 7FH 60H 80H 7FH 02H DA
ملخص المحتوى في الصفحة رقم 15
PDP-614MX External Control Manual ACK 7FH 60H 80H 0AH 01H DATA00 CKS DATA00: 01H : STD 02H : MOVIE1 03H : MOVIE2 04H : Default 05H : Dynamic 13. COLOR TEMP SELECT Function The external control equipment changes the COLOR TEMP of the plasma monitor. Transmission Data DFH 80H 60H 00H 01H DATA00 CKS DATA00 : 00H: low 01H: middle 02H: high 03H: middle low ACK 7FH 60H 80H 00H 01H DATA00 CKS DATA00 : 00H: low 01H: middle 02H: high 03H: middl
ملخص المحتوى في الصفحة رقم 16
PDP-614MX External Control Manual 15. GREEN Gain Data Function The external control equipment changes the GREEN Gain Data of the plasma monitor. Transmission Data DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS DATA00 : USER PICTURE Gain Flag 01H DATA01 : GREEN Gain Flag 02H DATA02 : GREEN Low D8H : -40 : FFH : -01 00H : 0 01H : +01 : 1EH : +30 DATA03: GREEN High D8H : -40 : FFH : -01 00H : 0 01H : +01 : 1EH : +30 ACK
ملخص المحتوى في الصفحة رقم 17
PDP-614MX External Control Manual 16. BLUE Gain Data Function The external control equipment changes the BLUE Gain Data of the plasma monitor. Transmission Data DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS DATA00 : USER PICTURE Gain Flag 01H DATA01 : BLUE Gain Flag 03H DATA02 : BLUE Low D8H :-40 : FFH : -01 00H : 0 01H : +01 : 1EH : +30 DATA03: BLUE High D8H :-40 : FFH : -01 00H : 0 01H : +01 : 1EH : +30 ACK 7F
ملخص المحتوى في الصفحة رقم 18
PDP-614MX External Control Manual 17. DNR MODE Set Function The external control equipment sets the NR (Noise Reduction) mode of the plasma monitor. Transmission Data DFH 80H 60H C0H 01H DATA00 CKS DATA00: 01H : OFF 02H : LOW 03H : MID 04H : HIGH ACK 7FH 60H 80H C0H 01H DATA00 CKS DATA00: 01H : OFF 02H : LOW 03H : MID 04H : HIGH 18. BASS Gain Data Function The external control equipment changes the BASS gain data of the plasma monitor. Transmission
ملخص المحتوى في الصفحة رقم 19
PDP-614MX External Control Manual 19. TREBLE Gain Data Function The external control equipment changes the TREBLE gain data of the plasma monitor. Transmission Data DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS DATA00 : USER PICTURE Gain Flag 05H DATA01 : TREBLE Gain Flag 04H DATA02 : TREBLE Gain F3H : -13 : FFH : -01 00H : 0 01H : +01 : 0DH : +13 ACK 7FH 60H 80H 7FH 02H DATA00 DATA01 CKS DATA00: USER PICTURE Gain Flag 05H DATA01
ملخص المحتوى في الصفحة رقم 20
PDP-614MX External Control Manual 0AH : 2.35:1 ACK 7FH 60H 80H 51H 01H DATA00 CKS DATA00 02H : WIDE 03H : ZOOM 04H : STD 05H : FULL 06H : DOT BY DOT 08H : UNDERSCAN 09H : 14:9 0AH : 2.35:1 20