ملخص المحتوى في الصفحة رقم 1
TECHNICAL MANUAL (Ver. 1.1)
FOR PIONEER PLASMA DISPLAY MONITOR WHEN USED WITH
VIDEO CARDS (EXPANSION SOLUTIONS CARDS)
PLASMA DISPLAY MONITOR: PDP-607CMX
VIDEO CARD: PDA-5003 / PDA-5004
TABLE TOP STAND: PDK-TS26
WALL MOUNT UNIT: PDK-WM03
SPEAKER SYSTEM: PDP-S55-LR
This manual provides precautions and information for installation, preparation, and handling of the Plasma Display and
its dedicated mounting hardware.
Before installation and preparatory work, choose a safe and appropriate site after t
ملخص المحتوى في الصفحة رقم 2
Table of Contents INTRODUCTION ..................................................................... 4 BEFORE BEGINNING ADJUSTMENT/SETTING 5.1 Before Beginning Adjustment .................................. 78 FEATURES .............................................................................. 5 5.1.1 Operation Mode ................................................ 78 SPECIFICATIONS 5.1.2 Combined Use of the Remote Control, 2.1 Specifications ....................................................
ملخص المحتوى في الصفحة رقم 3
Table of Contents 5.4 Integrator Mode ....................................................... 142 5.4.1 About the Integrator Mode ............................. 142 CAUTION 5.4.2 Example of Integrator Mode Operation .......... 143 • To prevent injury and material damage, thoroughly read 5.4.3 Adjustment and Setting in the Integrator this manual and all labels found on the equipment before Mode ............................................................... 144 1) PICTURE Adjustment .............
ملخص المحتوى في الصفحة رقم 4
Introduction Introduction The contents of “5.1 Before Beginning Adjustments (pg. 78)” and subsequent sections are premised on the PDP- 607CMX being equipped with the PDA-5003 or PDA-5004. Items that apply only when the PDA-5003 or PDA-5004 is installed are marked with a star ‘’. Precautions With the PDA-5003 or the PDA-5004 installed, the PDP-607CMX supports the following functions: Input/output terminals 7 PDA-5003 INPUT 1 Input • Component video signal • RGB signals from AV devices other than
ملخص المحتوى في الصفحة رقم 5
Features Features and Functions of this device ¶ Introduces newly developed Wide Plasma Panel The new, wide, high-precision plasma panel (1365x768 / 16:9) pushes the envelope of previous high-luminance panels, producing brighter, clearer images with higher contrast. ¶ ES Slot interface for enhanced potential The display has a built-in ES Slot Interface to allow card installation for the connection of external devices, thus enhancing its expansion potential. ¶ Supports wide range of computer sign
ملخص المحتوى في الصفحة رقم 6
Specifications Power requirements ........... AC 100 V to 120 V, 50 Hz/60 Hz 2.1 Specifications (The power unit range is from AC100 V to 240 V (50 Hz/60 Hz)) Light-emitting panel ..................... 60V type AC Plasma Panel In-rush ............................................................... less than 50 A 131.86 cm (W) × 74.19 cm (H) × 151.3 cm (diagonal) Power factor .................................................... more than 0.95 (NOTE 2) Aspect ratio .................................
ملخص المحتوى في الصفحة رقم 7
Specifications INPUT Response Signals INPUT 1 INPUT 2 7 PC signals supported 7 PC signals supported Refresh rate Refresh rate Resolution Resolution Remark Remarks (Dot x Line) (Dot x Line) Vertical Horizontal Vertical Horizontal 640x480 59.9 Hz 31.5 kHz 640x400 70.1 Hz 31.5 kHz NEC PC-9800 72.8 Hz 37.9 kHz 720x400 70.1 Hz 31.5 kHz NEC PC-9800 75 Hz 37.5 kHz 85.1 Hz 37.9 kHz 85 Hz 43.3 kHz 640x480 59.9 Hz 31.5 kHz 100.4 Hz 51.1 kHz 66.7 Hz 35.0 kHz Apple Macintosh 13” 120.4 Hz 61.3 kHz 72.8 Hz 37
ملخص المحتوى في الصفحة رقم 8
External Dimensions 2.2 External Dimensions WEIGHT: 62.0 kg (136.7 lbs) (without stand) MATERIAL: Front: Resin; Rear cover: Metal plate, Front protector panel: Glass TREATMENT: Front: Paint; Rear cover: Paint (All paints are Pioneer original colors) For packaging information, refer to “3.3.2 Unpacking” (pg. 21). (Unit: mm) : center of gravity TOP VIEW 1470 122.4 1372 1318.6 71.7 LED IR 45 7.5 7.5 592.5 61.7 LEFT SIDE VIEW RIGHT SIDE VIEW 141.9 98 402.8 360 51 42 38 28 99.3 45 367.8 12 17 BOTTOM
ملخص المحتوى في الصفحة رقم 9
External Dimensions IR LED 109 98 135 150 367.8 17 45 99.3 1212 28 38 42 402.8 51 360 98 141.9 9 ø2 ø10 30.3 10.5
ملخص المحتوى في الصفحة رقم 10
Controls and Connectors 2.3 Controls and Connectors Main unit 3 Main unit Operation panel on the main unit DISPLAY INPUT SCREEN SIZE – VOL + STANDBY/ON MENU / SET 4 506 7 8 9 2 1 Main unit Operation panel on the main unit 4 STANDBY/ON button ( ) 1 Remote control sensor Press to put the display in Standby or into operation. Point the remote control toward the remote sensor to operate the unit. 5 MENU button Press to open and close the on-screen menu. 2 STANDBY/ON indicator When the unit is oper
ملخص المحتوى في الصفحة رقم 11
Controls and Connectors Connection Panel When installing PDA-5003 INPUT3 INPUT4 AUDIO INPUT5 S-VIDEO VIDEO INPUT 3/4 ANALOG RGB AUDIO IN OUT R L G(ON SYNC)BR HD (H/V SYNC)VD R L !@ # $ % ~ When installing PDA-5004 COMPONENT INPUT3 INPUT4 INPUT5 S-VIDEO AUDIO VIDEO AUDIO VIDEO AUDIO RL IN OUT R L Y Pb/Cb Pr/Cr RL ^ & *( ) _ + - = IN OUT OUTPUT INPUT1 INPUT2 INPUT1 INPUT2 ANALOG RGB OUT ANALOG RGB IN DIGITAL RGB (D-Sub) (D-Sub) (DVI-D) RS-232C AUDIO AUDIO AUDIO COMBINATION 15 2 3 4 6789 0 Plasma D
ملخص المحتوى في الصفحة رقم 12
Controls and Connectors Video Card Section Video Card Section The video card provides three video input connectors, The video card provides three video input connectors, one video output connector, and two audio input one video output connector, and three audio input connectors. Consult the pages noted in parentheses ( ) connectors. Consult the pages noted in parentheses ( ) for details regarding connections to the various jacks for details regarding connections to the vari
ملخص المحتوى في الصفحة رقم 13
Pin layout 2.4 Pin layout INPUT1 (Mini D-sub, 15-pin connector; female) RS-232C terminal (D-sub 9-pin connector; male) pin layout pin layout (DCE format) 5 1 1 5 10 6 15 11 6 9 Pin No. Input Output Pin No. Signal 1R 1 NC (not connected) 2G 2 TxD (Transmit Data) 3B 3 RxD (Receive Data) 4 NC (not connected) 4 NC (not connected) 5 GND 5 GND 6 GND 6 NC (not connected) 7 GND 7 NC (not connected) 8 GND 8 RTS (Request To Send) 9 DDC +5V NC (not connected) 9 NC (not connected) 10 GND INPUT2 (DVI-D 24 pi
ملخص المحتوى في الصفحة رقم 14
Remote Control Unit 2.5 Remote Control Unit 1 SCREEN SIZE button Press to select the screen size. 2 INPUT buttons Press to select the input. 0 1 3 MENU button Press to reveal and hide the on-screen menu. - 4 ADJUST (5/∞/3/2) buttons 2 = Press to navigate menu screens and adjust various settings on the unit. 5 SET button Press to adjust or enter various settings on the unit. 3 ~ 6 SUB INPUT button Press to change subscreen inputs during multi- ! 4 screen display. 7 SPLIT button 5 Press to switch
ملخص المحتوى في الصفحة رقم 15
Installation Site Requirements 3.1 Installation Site Requirements If the site requires modifications or special preparations before installing the Plasma Display or its mounting hardware, obtain permission in advance from the building owner or building authorities. To ensure safety, it is also important to determine the strength of the installation site with the help of an authorized building contractor. Safety Precautions 1) Structure of the installation site Thoroughly study the structure of
ملخص المحتوى في الصفحة رقم 16
Installation Site Requirements 9) Temperature and humidity conditions • The installation site should meet the following conditions: • Operating temperatures: 0 °C to 40 °C (largely depending on installation conditions) • Operating humidity: 20 % to 80 % • Storage temperature: –20 °C to 60 °C • Storage humidity: 20 % to 90 % • Operating atmospheric pressure: 800 hPa to 1100 hPa • Storage atmospheric pressure: 700 hPa to 1114 hPa • We discourage installing electronic products such as this unit in
ملخص المحتوى في الصفحة رقم 17
Installation Conditions 3.2 Installation Conditions 3.2.1 Heat dissipation This unit has openings for effective ventilation. Vent locations are marked by arrows in the illustration below. The arrows show the direction of airflow. To allow proper dissipation of heat from the unit, do not cover these openings. (Unit : mm) 104.5 140.25 1176.4 744.4 108.4 36.4 124.4 92.4 124.4 124.4 92.4 124.4 36.4 108.4 A A A A A A A A FAN2 FAN1 FAN3 409.5 404.4 In a standard installation, three fans and part A dra
ملخص المحتوى في الصفحة رقم 18
Installation Conditions 3.2.2 Calculating heat quantity As a courtesy to our customers, we have included the power formula for calculating air conditioning needs. For power consumption, allow 500 W = 500 VA per unit. Since most of the power consumed is transformed into heat, power consumption may be regarded as roughly equal to generated heat. 1 Conversion to calories [W] × 0.86 = [kcal/h] Heat generated per display: 500 W × 0.86 = 430 kcal/h 2 Conversion to British Thermal Units [W] × 3.41 = [B
ملخص المحتوى في الصفحة رقم 19
Installation Conditions This unit is designed to be mounted using four bolt holes. For additional safety, we recommend securing it at four points on opposite sides of the horizontal and vertical center lines, as shown in the drawing below. Methods of securing Secured at four points Secured at four points (with mounting hardware attached to the sides) (with mounting hardware attached to the top and *Attach using M8x4. bottom) *Attach using M8x4. Take proper precautions to prevent pinching the pow
ملخص المحتوى في الصفحة رقم 20
Installation Conditions 3.2.4 Mounting surface warping The display incorporates glass. Before mounting the panel using hardware other than that provided by Pioneer, perform the following checks to confirm that the display is free from warps exceeding 1 mm*. Regarding the 1 mm limit: The panel frame may have a warp of up to 3 mm. If the total warp (the warp of the frame plus the warp of the mounting surface) exceeds 4 mm then the glass in the display may experience excessive stress. To ensure tha