ملخص المحتوى في الصفحة رقم 1
K
L
E
T
I
R
S
PRINTER’S INSTRUCTIONS:
INSTR,INSTL,LRA - LINEAR P/N: 228158 X12 - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 8.500” X 11.000” - SCALE: 1-1 - FOLDING: ALBUM-FOLD - BINDING: SADDLE-STITCH
LRA
Linear Residential Actuator
Installation Guide
CM
C US
Operator models contained in this manual
conform to UL325 standard for use in
Class I, II, III, and IV applications
USA & Canada (800) 421-1587 & (800) 392-0123
(760) 438-7000 - Toll Free FAX (800) 468-1340
www.linearcorp.com
T
E
E
T
ملخص المحتوى في الصفحة رقم 2
Table of Contents Pre-installation Information . . . . . . . . . . . . . . . . . . . . . . . .1 . . .Operation Indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 . . . . . . . . . . . Before You Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . Po .w .er-up Displa . . . y . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 . Always Check the Gate’s Action . . . . . . . . . . . . . . . . . . . .1 . . . .
ملخص المحتوى في الصفحة رقم 3
Pre-installation Information Safety Information and Warnings THE FOLLOWING FORMATS ARE USED FOR SAFETY NOTES Before You Begin... IN THESE INSTRUCTIONS. Before unpacking, inspect the carton for exterior damage . If CAUTION you find damage, advise the delivery carrier of a potential This type of warning note is used to claim . Inspect your package carefully . You can check your indicate the possibility of damage to the accessory box parts with the enclosed packing slip for your gate or ga
ملخص المحتوى في الصفحة رقم 4
Linear Actuator Operator Overview Wiring Specifications The Model LRA Residential Linear Actuator is designed Refer to the following steps for details on power and to open and close a light-duty residential swing gate . The accessory wiring for the operator . operator can be used in left-hand or right-hand swing gate WARNING installations on gates weighing up to 600 pounds . ALL AC ELECTRICAL CONNECTIONS TO THE POWER SOURCE AND The operator is connected by a cable to an APeX electronic THE
ملخص المحتوى في الصفحة رقم 5
Gate Layout Illustration LRA Linear Residential Actuator Installation Guide - 3 - 228158 Revision X13 2-3-2009 POST OR ENTRY 36" PILLAR GATE HINGE RECOMMENDED GATE FULLY CLOSED GATE TOP VIEW CONTROL LRA ACTUATOR IN BOX CLOSED POSITION MINIMUM BACKSPACE ROADWAY 8" FROM CENTER OF GATE HINGE LRA ACTUATOR IN OPEN POSITION LEFT HAND EXIT GATE OPERATION SHOWN GATE FULLY OPEN POST OR PILLAR GATE BACK SIDE VIEW CONTROL BOX LRA ACTUATOR 1/2 GATE HEIGHT LEAVE SLACK IN CABLE TO ALLOW FOR GATE SWING
ملخص المحتوى في الصفحة رقم 6
Mounting Bracket Installation LOCATE POST BRACKET AT THESE NOTE: THE 5-1/2" AND DIMENSIONS FROM THE GATE Examine Figure 2 for details of the required mounting locations 6" DIMENSIONS ARE CENTERLINE AND HINGE POINT CRITICAL FOR PROPER for the two brackets . The brackets must be mounted at the GATE OPERATION correct locations to allow the operator to open the gate at a 90 degree angle and to ensure the operator functions smoothly . The brackets must also be mounted level in respect to each oth
ملخص المحتوى في الصفحة رقم 7
Operator Setup Operator Mounting The operator mounts on the post bracket pin and into the gate bracket bushing . Refer to Figure 5 . TRAVELER 1. With the gate closed, carefully position the operator over the mounting SHAFT brackets. 2. Lower the operator onto the post bracket pin while guiding the operator’s worm drive traveler shaft into the gate bracket bushing. 3. Install the washer and clip-ring on the post bracket pin. GATE BRACKET 4. Install the washer and clip-ring on the traveler shaf
ملخص المحتوى في الصفحة رقم 8
Operator Setup (Continued) Limit Switch Adjustment SLIDE OPEN LIMIT SWITCH TO ADJUST OPEN LIMIT The open and close limit switches are adjustable by sliding them on the operator’s frame . Sliding either switch closer to the center of the operator decreases the gate travel . 1. To limit the opening travel of the gate for setup, loosen the locking screw on the open limit switch, slide the switch towards the center of the operator (see Figure 8). 2. With the gate closed, apply power to the Contr
ملخص المحتوى في الصفحة رقم 9
Controller Features WHIP ANTENNA ANTENNA CONNECTOR OPERATION AND POWER PROGRAMMING OPERATION INDICATORS INDICATORS BUTTONS DISPLAY PROGRAMMING SOLAR BUTTONS PANEL TERMINALS INPUT POWER MOTOR TERMINALS BOARD COVER ACCESSORY POWER BATTERY TERMINALS TERMINALS RESET BUTTON PLUG-IN TERMINALS LOOP PRIMARY/ DETECTOR SECONDARY CONNECTORS COMM LINK TERMINALS SINGLE INPUT TERMINALS FIRE DEPT INPUT TERMINALS OPEN INPUT TERMINALS 3-BUTTON SHADOW/RESET STATION TERMINALS AUXILIARY OPEN AND CLOSE REVERSE LOOP
ملخص المحتوى في الصفحة رقم 10
Indicator Descriptions INDICATOR DEFINITION INDICATION WHEN LIT INDICATION WHEN LIT DURING NORMAL OPERATION DURING PROGRAMMING OPERATION PROGRAMMING 24 VOLT INPUT LOW VOLTAGE AC POWER IS PRESENT POWER 24 VOLT DC LOW VOLTAGE DC POWER IS PRESENT ACCY POWER OPEN SIGNAL PRESENT FROM THE INTERNAL OPEN RECEIVER OR AN EXTERNAL DEVICE CONNECTED TO THE OPEN INPUT TERMINAL CLOSE SIGNAL IS PRESENT FROM A DEVICE CLOSE CONNECTED TO THE CLOSE INPUT TERMINAL STOP INPUT TERMINAL IS OPEN AND STOP NOT CONN
ملخص المحتوى في الصفحة رقم 11
Terminal Descriptions TERMINAL GROUP FUNCTION AC N FACTORY CONNECTED TO 24 VAC FROM TRANSFORMER OR 24 VOLT INPUT 24 VDC FROM CONTINUOUS DUTY DC SUPPLY. AC DC - ACCESSORY POWER PROVIDES 24 VOLT DC POWER FOR ACCESSORIES. (.5A MAX) DC + RESET RESET BUTTON FACTORY CONNECTED TO THE CONTROLLER’S RESET BUTTON. COMMON C B COMM LINK FOR 3-WIRE NETWORK CONNECTION TO SECOND OPERATOR IN DUAL GATE INSTALLATIONS. A COMMON CONNECT TO NORMALLY OPEN SWITCH FOR SINGLE BUTTON OPERATION. ALTERNATES SINGLE BUTTON
ملخص المحتوى في الصفحة رقم 12
Operator Accessory Connections 3-BUTTON STATION PHOTOEYE FOR REVERSE TELEPHONE ENTRY KEYPAD PHOTOEYE FOR CLOSE OBSTRUCTION KEYSWITCH FIRE ACCESS SWITCH SOLENOID LOCK EXTERNAL POWER PHOTOEYE FOR OPEN OBSTRUCTION SINGLE-CHANNEL RADIO RECEIVER MAGLOCK GATE EDGE SENSOR FOR REVERSE TWO-CHANNEL RADIO RECEIVER WARNING STROBE OR AUDIBLE SOUNDER CHANNEL #1 WIRELESS GATE EDGE SENSOR OPEN/CLOSE MGT TRANSMITTER Figure 13. Operator Accessory Connections LRA Linear Residential Actuator Installation Guide - 10
ملخص المحتوى في الصفحة رقم 13
Basic Controller Programming Programming Overview PROGRAM The Controller can be programmed with various options for the operator. INDICATOR The programming fields are defined as “functions” that have “options”. DOWN AND UP To make setup easier for the installer, the Controller’s programming is divided into two groups: basic and advanced. The basic programming PRESS DOWN AND UP PROGRAM INDICATOR group contains the functions commonly used in most swing gate BUTTONS TOGETHER WILL LIGHT WHEN SYS
ملخص المحتوى في الصفحة رقم 14
Basic Controller Programming (Cont.) FUNCTION OPTIONS Run Alarm and Pre-start Alarm RUN ALARM OFF "RP" The factory default is Run Alarm on and a 3-second Pre-start Alarm. The PRE-START ALARM OFF operator’s beeper will sound 3 seconds before the operator starts. The options are: RUN ALARM ON PRESS UP OR PRE-START ALARM OFF DOWN TO CYCLE • Run Alarm Off and Pre-start Alarm Off THROUGH OPTIONS • Run Alarm On and Pre-start Alarm Off RUN ALARM ON PRESS ENTER TO • Run Alarm On and Pre-start Alarm
ملخص المحتوى في الصفحة رقم 15
Advanced Controller Programming FUNCTION OPTIONS Entering Advanced Programming Mode ADVANCED PROGRAMMING FUNCTIONS "AD" To access and program the Advanced Programming functions, for each WILL NOT BE DISPLAYED programming session, Advanced Programming must be enabled. ADVANCED PROGRAMMING OPTIONS After exiting programming, the Advanced Programming functions WILL BE DISPLAYED will be available on the programming display during the next programming session unless the operator has run 50 or more
ملخص المحتوى في الصفحة رقم 16
Advanced Controller Programming (Cont.) FUNCTION OPTIONS Auxiliary Relay Mode AUXILIARY RELAY DISABLED "AR" The Auxiliary Relay has normally open and normally closed contacts. The factory setting disables the Auxiliary Relay. The relay can be set for: AUXILIARY RELAY USED FOR MAGLOCK CONTROL • Maglock: The relay will energize during any pending or actual gate PRESS UP OR DOWN TO CYCLE motion (open only), to deactivate a magnetic or solenoid gate lock. AUXILIARY RELAY USED FOR THROUGH OPTIONS
ملخص المحتوى في الصفحة رقم 17
Advanced Controller Programming (Cont.) FUNCTION OPTIONS Soft Start/Stop Duration SOFT START DISABLED "SS" This function causes the operator to start and stop the DC motor slowly reducing gate wear and tear (at the full open or closed positions only). SET SOFT START DURATION TIME The factory default sets the Soft Start/Stop Duration to 3 seconds. The FROM 1 TO 10 SECONDS Soft Start/Stop Duration can be set from 1 to 10 seconds. PRESS UP OR ✓ NOTE: Changing the Soft Start/Stop Duration will re
ملخص المحتوى في الصفحة رقم 18
Advanced Controller Programming (Cont.) FUNCTION OPTIONS Radio Enable "RA" INTERNAL RADIO RECEIVER DISABLED ® The Controller contains a built-in MegaCode radio receiver to allow activation from up to 40 access control transmitters and two Model MGT (gate edge) transmitters. The factory default enables the internal radio INTERNAL RADIO RECEIVER ENABLED receiver. Alternately, the internal receiver can be disabled. PRESS UP OR Antenna Installation DOWN TO CYCLE THROUGH OPTIONS The Controller is
ملخص المحتوى في الصفحة رقم 19
Loop Layout Illustration LRA Linear Residential Actuator Installation Guide - 17 - 228158 Revision X13 2-3-2009 2" MAX. USE RELIEF CUTS 3/8" AT CORNERS WALL PARTIALLY TWIST WIRE FROM END OF SHOWN FOR CLARITY LOOP LOOPS BACK TO OPERATOR SEALANT AT LEAST SIX TIMES PER FOOT 2" MULTIPLE TURNS REFER TO LOOP INSTALLATION NOTES FOR DETAILS 6 FT. OPEN GATE PARTIALLY SHOWN 4 FT. MINIMUM NOTE: POSITION SHADOW LOOP WITH A MINIMUM OF 4' CLEARANCE FROM GATE'S FULLY OPEN OR CLOSED POSITION NOTE: POSITION SHA
ملخص المحتوى في الصفحة رقم 20
Safety Edge Layout Illustration LRA Linear Residential Actuator Installation Guide - 18 - 228158 Revision X13 2-3-2009 WARNING One or more contact sensors shall be located on the inside and outside leading edge of a swing gate. RECEIVER FOR GATE EDGE TRANSMITTER Additionally, if the bottom edge of a swing gate is BUILT INTO CONTROLLER greater than six inches (152 mm) above the ground at any point in its arc of travel, one or more contact sensors shall be located on the bottom edge. GATE