ملخص المحتوى في الصفحة رقم 1
PRINTER’S INSTRUCTIONS:
INSTR,INSTL,AE-100 - LINEAR P/N: 225787 C - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 8.500” X 11.000” - SCALE: 1-1 - FOLDING: ALBUM-FOLD - BINDING: SADDLE-STITCH
AE-100
Commercial
Telephone Entry
System
Installation and
Programming Instructions
USA & Canada (800) 421-1587 & (800) 392-0123
(760) 438-7000 - Toll Free FAX (800) 468-1340
www.linearcorp.com
ملخص المحتوى في الصفحة رقم 2
Contents Hardware Features Introduction ............................................... 2 Programming Over the Telephone .......... 15 ✓ 2-LINE, 16-CHARACTER-PER-LINE LCD DISPLAY Hardware Features ................................... 2 Multi-unit Installations ............................. 16 LED backlit display with easy-to-read .3” high characters Software Highlights ................................... 2 Changing the Master Password ............. 16 Feature Overview ............................
ملخص المحتوى في الصفحة رقم 3
Feature Overview Operation In a typical installation, the unit’s memory is programmed with each Installer Friendly Programming resident’s Directory Code, Name, Telephone Number, and Entry Code. To make it easy for installers familiar with Linear’s and other manufacturer’s access control systems, two methods of programming Arriving visitors use the or keys to view the Name and Directory are available. Step numbers or function codes that match other Code for the desired resident. Upon ente
ملخص المحتوى في الصفحة رقم 4
Component Locations CABINET LOCK MICROPHONE CAMERA (OPTIONAL) LCD POSTAL DISPLAY LOCK (OPTIONAL) KEYPAD SPEAKER LIGHTING INSTALLATION NOTE: FOR EASY WIRING, THE UNIT'S TTY KEYPAD JACK GREEN TERMINAL BLOCKS CAN BE UN-PLUGGED BATTERY SPEAKER FROM THE CIRCUIT BOARD CONNECTOR CONNECTOR EARTH TTY GROUND EARTH CONNECTOR STUD GROUND VIDEO OUT CONNECTOR CONNECTOR BACKUP BATTERY (OPTIONAL) POSTAL SWITCH CONNECTOR ACCESS SPEAKER RELAY TERMINALS DIGITAL SPEECH POSTAL LOCK VOLUME POWER MICROSWITCH ADJUSTMEN
ملخص المحتوى في الصفحة رقم 5
Wiring Diagram CASE EARTH GROUND GROUND AE-100 CIRCUIT BOARD STUD STAKE EARTH GROUND BACKUP BATTERY INTERNAL 1.2 AMP/HOUR P/N 100104 12 VOLT BACKUP BATTERY EXTERNAL UP TO 7 AMP/HOUR BATTERY TTY JACK ACCESS RELAY ELECTRIC 10 AMPS @ 30 VOLTS AC DOOR STRIKE SPEAKER 7 AMPS @ 30 VOLTS DC MAXIMUM VIDEO OUT TO VIDEO DOOR STRIKE MONITOR OR POWER SUPPLY MODULATOR POSTAL LOCK N.O. COM ACCESS RELAY N.C. 16 VAC 20 VA 16 VAC INPUT TRANSFORMER DIGITAL MAIN SPEECH POWER CONNECT TO MODEL CCM-1 CAMERA VOLUME SWI
ملخص المحتوى في الصفحة رقم 6
? ? ? Important Mounting Requirements The AE-100 Telephone Entry System can be installed for public or private use. The mounting requirements will vary depending on the installation. Review the following information before beginning the installation. Mounting Environment Consider the environmental factors at the desired mounting location. The AE-100 is designed for direct outdoor installations, however, it is preferable to protect the unit from extreme exposure to sun, driving rain, or snow
ملخص المحتوى في الصفحة رقم 7
Entry System Mounting SURFACE The AE-100 cabinet is designed to be mounted three ways: MOUNTING • The unit can be mounted directly to a wall or fl at surface. • The unit can be mounted recessed into a wall. • The unit can be mounted on a standard goose-neck pedestal. Choose a well lit location near the controlled opening. Wiring access for power, telephone, earth ground, and access output must be available to the mounting location. Static Electricity Warning MARK THE FOUR 1 The unit’s main cir
ملخص المحتوى في الصفحة رقم 8
Entry System Mounting (Continued) Recessed Mounting The cabinet can be mounted recessed using the accessory trim-ring DETERMINE LOCATION FOR MARK HOLE LOCATION 1 2 THE 10" x 12" MOUNTING HOLE Model TR-100 (P/N ACP00941). The trim-ring mounts in the wall and the cabinet attaches to the trim-ring. RECESSED 1. Identify the location of any studs in the wall. MOUNTING ✦ CAUTION!: Watch out for wiring inside the wall. 2. Determine and mark the 12” high by 10” wide hole location. 12" 3. Cut the rectan
ملخص المحتوى في الصفحة رقم 9
Access Relay Wiring TYPICAL DOOR STRIKE HOOKUP The access relay controls access devices, such as a door strike, magnetic ELECTRIC N.O. lock, automatic door, barrier gates, or automatic sliding gate. The RELAY DOOR ACCESS COM indicator displays the status of the relay. STRIKE RELAY N.C. Door or Pedestrian Gate Control DOOR 1. Install a low voltage electric door strike or magnetic lock STRIKE POWER SUPPLY as a locking device for the door or pedestrian gate. 2. Install the power supply or transfo
ملخص المحتوى في الصفحة رقم 10
Multiple Unit Telephone Wiring Up to four AE-100 units may be connected to the same dedicated telephone line to form a simple network. Connecting multiple units allows MULTIPLE UNIT HOME RUN WIRING transferring programming data (either the directory entries only or the AE-100 entire memory’s contents) from the “master” unit to the other sub-units. SUB-UNIT "2" ✦ NOTE: For a multiple-unit installation to function properly, be sure to set programming Steps #07 & #71 TELEPHONE TERMINALS Multipl
ملخص المحتوى في الصفحة رقم 11
Power, Battery, & Ground Wiring Power Wiring ✦ NOTE: DO NOT APPLY POWER UNTIL THE INSTALLATION IS COMPLETE. TURN MAIN POWER SWITCH OFF BEFORE 16 VAC 16 VAC WIRING. POWER 20 VA 1. Route two wires between the AE-100 and the power transformer. TERMINALS TRANSFORMER � For power wire runs up to 100 feet, use 18 AWG, THHN 600-volt insulated wire. PLUG-IN TRANSFORMER � For power wire runs up to 200 feet, use 16 AWG, THHN 600-volt insulated wire. 2. Connect the wires to the transformer. Connect the
ملخص المحتوى في الصفحة رقم 12
Optional Postal Lock 1 REMOVE LOCKNUTS 2 REMOVE PLATE & PLUG A postal lock can be installed in the AE-100 Entry System to provide keyed access for the postal service. The AE-100 case is designed to accept a U.S. Postal Service postal lock. When the postal lock is engaged the access relay will activate. Postal Lock Installation 1. Remove the four locknuts that retain the postal lock cover plate and block (above the speaker on the AE-100 faceplate). 2. Remove the cover plate and block from the
ملخص المحتوى في الصفحة رقم 13
Programming Reference & Factory Defaults STANDARD ALTERNATE FACTORY PROGRAMMING FUNCTION FUNCTION OF PROGRAMMING STEP DEFAULT POSITION CODE VALUE NUMBER NUMBER 99 91 EXIT PROGRAM MODE SYSTEM OPTIONS 01 00 CHANGE MASTER PASSWORD 123456 02 06 DIRECTORY CODE LENGTH 3 07 07 SET SUB-UNIT NUMBERS NOT SET 38 38 SYSTEM DISPLAY LANGUAGE ENGLISH 51 72 KEYPAD LOCKOUT COUNT 3 TRIES 52 71 ACCESS RELAY ACTIVATION TIME 4 SECONDS LINEAR ACCESS 57 10 WELCOME DISPLAY TEXT TELEPHONE ENTRY 61 74 AUTOMATIC TELEPH
ملخص المحتوى في الصفحة رقم 14
Access to Programming To make it easy for installers familiar with Linear’s and other manufacturer’s access control systems, two methods of programming are available. Programming Position Numbers (or Function Codes) that match other PRESS AND TOGETHER equipment help the installer to make quick programming changes with keystrokes they’ve used before. FOR Automatic Programming Method Selection The Programming Position Numbers (or Function Codes) change STANDARD PROGRAMMING METHOD depending on
ملخص المحتوى في الصفحة رقم 15
Programming Over the Telephone Most system commands can be programmed using a TouchTone™ CONNECTING WITH A TELEPHONE telephone. The telephone’s keypad will act similar to the AE-100’s keypad. 1. CALL THE SYSTEM Both programming methods can be used over the telephone. 2. SYSTEM ANSWERS ON THIRD RING Connecting with a Telephone 1. Place a call to the telephone number of the 3. SYSTEM SOUNDS THE CURRENT STATUS: line that the AE-100 is connected to. > ONE SHORT BEEP - ALL RELAYS ON > TW
ملخص المحتوى في الصفحة رقم 16
STANDARD PROGRAMMING METHOD Multi-unit Installations NOTE: Up to four AE-100 units may be connected to the same dedicated AFTER SETTING UP A MULTI-UNIT INSTALLATION WITH telephone line to form a simple network. Connecting multiple units allows THESE STEPS, WRITE IN THE UNIT LOCATIONS BELOW AND transferring programming data (either the directory entries only or the ON PAGE 6 IN THE FACILITY MANAGER’S GUIDE TO INDICATE entire memory’s contents) from the “master” unit to the other sub-units
ملخص المحتوى في الصفحة رقم 17
STANDARD PROGRAMMING METHOD Resident Data Programming Up to 125 resident Names and Telephone Numbers can be set. Each resident entry is assigned a Directory Code. The Directory Code is the number visitors enter to have the system call the resident. Visitors can also contact a resident displayed by pressing the key. Use the programming worksheet supplied to organize the resident data prior to entering it into the system. For each of the following steps, enter the Master Password and enter P
ملخص المحتوى في الصفحة رقم 18
STANDARD PROGRAMMING METHOD Stand-alone Entry Code Programming A Stand-alone Entry Code is a number entered at the AE-100 keypad to request access. Up to 125 4-digit Stand-alone Entry Codes can be set. ✦ NOTE: Each Stand-alone Entry Code programmed reduces the possible number of Directory Entries by one. Use the programming worksheet supplied to organize the Stand-alone Entry Code data prior to entering it into the system. For each of the following steps, enter the Master Password and enter
ملخص المحتوى في الصفحة رقم 19
STANDARD PROGRAMMING METHOD System Options (Continued) Keypad Lockout Count KEYPAD LOCKOUT COUNT PPN 51 The system counts the number of invalid Entry Codes entered at the keypad. If the invalid entries exceeds the lockout count number, the keypad is locked out for 90 seconds. The factory setting for the lockout 51#COUNT# count is three. The lockout value can be from one to nine. 1. Press COUNT = NUMBER (1-9) OF INCORRECT ENTRIES 2. Enter the number for the lockout count (1-9). THAT WILL C
ملخص المحتوى في الصفحة رقم 20
STANDARD PROGRAMMING METHOD System Options (Continued) Speaker Tone on Access Relay Activation SPEAKER TONE ON ACCESS RELAY ACTIVATION PPN 63 The factory setting will cause the speaker to sound a tone for two seconds when the access relay is activated. Alternately, the tone can be turned off. 63#TONE# 1. Press 2. Select the option for access relay activation tone: TONE = 0 FOR ACCESS RELAY TONE OFF � Enter 0 to turn OFF the access relay activation tone. TONE = 1 FOR ACCESS RELAY TONE ON �