ملخص المحتوى في الصفحة رقم 1
Operations Manual
Operational instructions for Humminbird Legend 2000 Series
including the Legend –2000, 2005, 2000 Deep and 2005 Deep
ملخص المحتوى في الصفحة رقم 2
THANK YOU Thank you for choosing Humminbird®, America's#1 name in fishfinders. Humminbird has built its reputation by designing and manufacturing top-quality, thoroughly reliable marine equipment. Your Humminbird is designed for trouble-free use in even the harshest marine environment. In the unlikely event that your Humminbird does require repairs, we offer an exclusive Service Policy - free of charge during the first year after purchase, and available at a reasonable rate after the one-year pe
ملخص المحتوى في الصفحة رقم 3
TABLE OF CONTENTS Section 1: USING The Legend 2000 Series . . . . . . . . . . . . . . . . . . . . . . . . . 2 Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Deep Models Additional Performance . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Powering Up the Unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Simulator and Feature Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 User Inter
ملخص المحتوى في الصفحة رقم 4
USING THE LEGEND 2000 SERIES PERFORMANCE / SIMULATOR / POWERING UP THE UNIT Powering Up the Unit After installation, turn the LEGEND 2000 SERIES on by momentarily pressing the GAIN knob. An audible chirp sounds as the unit turns on. If the unit detects that the transducer is connected and is in water, the LEGEND 2000 SERIES begins to show sonar information on the display. If the transducer is not detected, the unit starts up in SIMULATOR mode. To power the unit off at any time, press and hold th
ملخص المحتوى في الصفحة رقم 5
USING THE LEGEND 2000 SERIES USER INTERFACE / KNOBS / LCD DISPLAY Range Knob USER INTERFACE The RANGE knob adjusts the The LEGEND 2000 SERIES User Interface is depth ranges used on the made up of the following components: display. The RANGE knob has Push ON / OFF knobs and the LCD Display, which in slightly different capabilities in turn is made up of the RTS (Real Time each mode of operation. See Sonar™) and the Chart Windows. MODES OF OPERATION for specific Knobs information. In all modes, Thr
ملخص المحتوى في الصفحة رقم 6
USING THE LEGEND 2000 SERIES REAL TIME SONAR™ / CHART WINDOW The sonar returns received by the LEGEND 2000 SERIES are Fish appear as smaller groupings of sonar returns displayed along the depth range scale in a REAL TIME between the bottom and surface. Often, large fish SONAR™ (RTS) WINDOW and CHART WINDOW. The RTS WINDOW within a structure will show as a strong return within a displays new sonar information within the transducer grouping of smaller returns. When the boat is cone in an expanded,
ملخص المحتوى في الصفحة رقم 7
USING THE LEGEND 2000 SERIES CHART WINDOW / BOTTOMS / FISH APPEARANCE A thermocline typically appears as a continuous band of many gray levels moving across the display at the Thermocline same depth. Thermoclines always appear above the bottom. Slope Second Return Bait fish Fish Arch Partial Fish Sloped Bottoms Arch Bottoms having a large degree of slope also present a Structure unique picture. These generally have a thicker black band representing the bottom directly under the boat. Equal area
ملخص المحتوى في الصفحة رقم 8
USING THE LEGEND 2000 SERIES SONAR VIEWS / CONTROL PANELS Sonar Views (Deep Models Only) The CONTROL PANEL NAME indicates the feature, the SETTING The dual beam (50/200kHz) sonar information can be INDICATOR shows the current setting within the complete displayed in several different views in the CHART WINDOW. In the range of adjustment, and the SETTING READOUT shows the 200kHz view, only the sonar returns and FISH ID from the status when CONTROL PANEL is not selected. 200kHz beam are displayed.
ملخص المحتوى في الصفحة رقم 9
USING THE LEGEND 2000 SERIES MODES OF OPERATION / OPTIMIZING THE DISPLAY Optimizing the Depth Range for Sonar Targets Optimizing the Depth Range for Second Return When the image of the To optimize the depth bottom does not appear range for viewing the close to the bottom of second return, follow the LCD display, the these steps. Legend 2000 Series is 1. Make sure the LEGEND 2000 not fully optimizing the SERIES is operating in display to show sonar Automatic. targets, such as fish, that 2. Push t
ملخص المحتوى في الصفحة رقم 10
USING THE LEGEND 2000 SERIES BOTTOM LOCK ZOOM MODE / MANUAL MODE To change the area of the bottom being zoomed, To adjust the depth ranges manually, follow these follow these steps: steps: 1. Make sure the LEGEND 2000 SERIES is operating in BTM LOCK (Bottom 1. Make sure the Legend 2000 Series is operating in Manual mode. Lock) mode. 2. Push the Range knob. An adjustment indicator appears at the 2. Push the RANGE knob. An adjustment indicator appears by the lower location of the Lower Depth Range
ملخص المحتوى في الصفحة رقم 11
USING THE LEGEND 2000 SERIES CHART SPEED / SONAR VIEW / LIGHT / CONTRAST / RTS WINDOW The CONTRAST setting is retained in memory after the unit is turned off as Sonar View long as it is set between 6 and 10. The factory setting is 8. SONAR VIEW (Deep Models only) selects the source of the sonar information being RTS Window displayed. 200kHz displays RTS WINDOW selects the width of sonar information and FISH ID the window dedicated to REAL from the 200kHz beam only. TIME SONAR™. Selecting NARROW
ملخص المحتوى في الصفحة رقم 12
USING THE LEGEND 2000 SERIES SURFACE CLUTTER / WHITE LINE / FILTER / DEPTH ALARM / TEMP ALARM White Line not sound again until the boat moves to water WHITE LINE activates and deeper than the DEPTH ALARM setting. International adjusts a feature models have Depth Alarm settings in metres which changes how and fathoms the LEGEND 2000 SERIES Note: Remember that depth is measured from the draws the bottom transducer, not from the surface of the water. contour and The DEPTH ALARM setting returns to f
ملخص المحتوى في الصفحة رقم 13
USING THE LEGEND 2000 SERIES UPPER TEMP / LOWER TEMP / FISH ALARM / FISH SENSITIVITY / FISH ID / SIMULATOR / UNITS UPPER TEMP is the upper Fish ID temperature boundary for the FISH ID (Deep Models only) uses temperature alarm. The inside advanced signal processing to temp alarm will sound when evaluate further any sonar the water temperature was initially above the upper return between the surface temp boundary and then falls below it. The outside and the bottom. If the return meets certain addi
ملخص المحتوى في الصفحة رقم 14
MAINTENANCE AND WARRANTY CONTROL PANELS / MAINTENANCE/TROUBLESHOOTING UNITS also selects the units of measure for boat speed cling to the surface of the transducer and interfere and depth in one of four additional combinations with proper operation. These bubbles dissipate with supported by the International Models only: time, or you can wipe the face of the transducer with your fingers after the transducer is in the water. • METRES/KPH displays depth in metres/speed in kilometres per hour. • ME
ملخص المحتوى في الصفحة رقم 15
MAINTENANCE AND WARRANTY TROUBLESHOOTING 2. The unit starts up in Simulator mode. 4. When in very shallow water, I get gaps in the bottom The LEGEND 2000 SERIES has the ability to detect that a reading and inconsistent digital depth indications. transducer is connected. If, at power up, a transducer The LEGEND 2000 SERIES will work reliably in water 2' (.6m) or is not connected, the unit starts up in SIMULATOR mode. deeper. Remember that the depth is measured from the transducer, not necessarily
ملخص المحتوى في الصفحة رقم 16
MAINTENANCE AND WARRANTY WARRANTY / SERVICE POLICY Techsonic Industries Service Policy TECHSONIC INDUSTRIES,INC. Even though you'll probably never need to take advantage of our ONE YEAR LIMITED WARRANTY incredible service policy, it's good to know that we back our products this We warrant the original retail purchaser that products made by Techsonic confidently. We do it because you deserve the best. We will make every Industries have been manufactured free from defects in materials and effort t
ملخص المحتوى في الصفحة رقم 17
CUSTOMER RESOURCE CENTER SERVICE POLICY / SERVICE PROCEDURES Returning Your Unit for Service For OUT-OF-WARRANTY service, complete the following steps: Before sending your unit in for repair, please contact the factory, either by • Obtain a Repair Authorization Number from Techsonic Industries phone or by email, to obtain a Repair Authorization Number for your unit. Customer Resource Center. Please have your product model name and serial number available before • Included payment in the form of
ملخص المحتوى في الصفحة رقم 18
SPECIFICATIONS 2000/2005 SPECIFICATIONS 2005/2005 DEEP SPECIFICATIONS (INTERNATIONAL MODELS) Operating Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200 kHz Power Output . . . . . . . . . . . . . . . . . . . . . . .4000 Watts (Peak to Peak) Languages Supported Include: English, Dansk, Deutsch, Español, Finnish/Svomi, Français, Italiano, Nederlands, Norsk, Portuquês, Svenska, . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500 Watts (RMS)