This manual provides critical safety instructions on the proper setup, operation, maintenance, and service of this machine/tool. Save this document, refer to it often, and use it to instruct other operators. Failure to read, understand and follow the instructions in this manual may result in fire or serious personal injury—including amputation, electrocution, or death. The owner of this machine/tool is solely responsible for its safe use. This responsibility includes but is not limited to
ملخص المحتوى في الصفحة رقم 3
Table of Contents INTRODUCTION ............................................... 2 SECTION 1: SAFETY ....................................... 9 SECTION 5: ACCESSORIES ......................... 44 SECTION 2: POWER SUPPLY ...................... 12 SECTION 6: OPERATIONS ........................... 46 SECTION 7: MAINTENANCE ......................... 47
ملخص المحتوى في الصفحة رقم 4
INTRODUCTION Manual Accuracy Contact Info your machine may not exactly match the manual Machine Description www.grizzly.com
ملخص المحتوى في الصفحة رقم 5
Identification Figure 1. To reduce the risk of serious injury when using this machine, read and understand this entire manual before beginning any operations.
ملخص المحتوى في الصفحة رقم 6
Glossary Of Terms Air Suction Capacity: Duct Grounding: Main Line: Branch Line: Main Line Velocity Velocity Machine CFM Requirement: Collection Bag/Drum: CFM (Cubic Feet per Minute): Dust Collection System Cyclone: Powered Air Filter: Duct (Ducting):
ملخص المحتوى في الصفحة رقم 7
G0637 Machine Data Sheet Customer Service #: (570) 546-9663 · To Order Call: (800) 523-4777 · Fax #: (800) 438-5901
Weight.............................................................................................................................................................. 712 lbs. Width (side-to-side) x Depth (front-to-back) x Height............................................................. 76-3/4 x 59-3/8 x 137 i
ملخص المحتوى في الصفحة رقم 8
Dust Collector Type............................................................................................................................... Cyclone Filter Type............................................................................................................................... Pleated Cartridge Airflow Capacity........................................................................................................... 3468 CFM @4.3 in. S.P. Max Static Pressure...........
ملخص المحتوى في الصفحة رقم 9
G0638 Machine Data Sheet Customer Service #: (570) 546-9663 · To Order Call: (800) 523-4777 · Fax #: (800) 438-5901
Weight.............................................................................................................................................................. 758 lbs. Width (side-to-side) x Depth (front-to-back) x Height...................................................... 76-3/4 x 59-7/8 x 139-3/8 in. Foo
ملخص المحتوى في الصفحة رقم 10
Dust Collector Type............................................................................................................................... Cyclone Filter Type............................................................................................................................... Pleated Cartridge Airflow Capacity........................................................................................................... 4029 CFM @4.3 in. S.P. Max Static Pressure...........
ملخص المحتوى في الصفحة رقم 11
SECTION 1: SAFETY For Your Own Safety, Read Instruction Manual Before Operating this Machine The purpose of safety symbols is to attract your attention to possible hazardous conditions. This manual uses a series of symbols and signal words intended to convey the level of impor- tance of the safety messages. The progression of symbols is described below. Remember that safety messages by themselves do not eliminate danger and are not a substitute for proper accident prevention measures. Indica
ملخص المحتوى في الصفحة رقم 12
DISCONNECTING POWER SUPPLY. GUARDS & COVERS. NEVER STAND ON MACHINE. APPROVED OPERATION. STABLE MACHINE. DANGEROUS ENVIRONMENTS. AWKWARD POSITIONS. ONLY USE AS INTENDED. UNATTENDED OPERATION. OFF USE RECOMMENDED ACCESSORIES. MAINTAIN WITH CARE.
ملخص المحتوى في الصفحة رقم 13
Additional Safety for Dust Collectors INTENDED USE. SUSPENDED DUST PARTICLES AND IGNITION SOURCES. FIRE SUPPRESSION. HAZARDOUS DUST. IMPELLER HAZARDS. DUST ALLERGIES. AVOIDING SPARKS. WEAR RESPIRATOR. OFF EMPTYING DUST. OPERATING LOCATION. DISCONNECTING POWER SUPPLY. OFF
ملخص المحتوى في الصفحة رقم 14
SECTION 2: POWER SUPPLY Availability Circuit Information For your own safety and protection of property, consult an electrician if you are unsure about wiring practices or electrical codes in your area. Electrocution, fire, or equipment damage may occur if machine is not Note: The circuit requirements listed in this man- correctly grounded and ual apply to a dedicated circuit—where only one connected to the power mach
ملخص المحتوى في الصفحة رقم 15
Connection Type Extension Cords Figure Phase Converter 3L/2 1L/2 5L/3 Figure 2. Grounding Instructions Serious injury could occur if you connect the machine to power before completing the setup process. DO NOT connect to power until instructed later
ملخص المحتوى في الصفحة رقم 16
5. Model G0637 440V Conversion Figure 4 Wiring Diagrams Pages 54–55 Figure 4. To convert the G0637 to 440V: 6. 1. Figure 5 2. 3. 4. Figure 3 Figure 5. Figure 3.
ملخص المحتوى في الصفحة رقم 17
5. Model G0638 440V Conversion Figure 6 6. To convert the G0638 to 440V: Figure 8 1. 2. Figure 6 Figure 8. 7. Figure 8 Figure 6. You must have a qualified electrician inspect your 440V rewiring job before connecting 3. the dust collector to the power source. Failure to heed this warning may result in property dama
ملخص المحتوى في الصفحة رقم 18
3. Correcting Phase Polarity 4. Step 10 Page 34 NOTICE If this machine is wired out-of-phase, the motor and impeller will spin in the wrong direction. The efficiency of the dust col- lector will be greatly reduced and will not provide the rated CFM. You must make sure the motor is spinning in the correct direction before placing the machine into full operation. Perform Step 10 of the test run on Page 34
ملخص المحتوى في الصفحة رقم 19
SECTION 3: SETUP Needed for Setup This machine presents serious injury hazards to untrained users. Read through this entire manu- al to become familiar with Description Qty the controls and opera- tions before starting the machine! Wear safety glasses dur- ing the entire setup pro- cess! This machine and its com- ponents are very heavy. Get lifting help or use Unpacking power lifting equipment such as a forklift to move heavy items
ملخص المحتوى في الصفحة رقم 20
Inventory P. Inventory Q. R. S. T. U. V. Inventory: (Figures 10–14) Qty W. A. X. B. C. D. E. F. G. H. I. Figure 12. Y. Z. AA. Figure 10. J. AB. K. AC. L. AD. M. N. O. Figure 13. Figure 11.