ملخص المحتوى في الصفحة رقم 1
INSTALLATION INSTRUCTIONS
TM
DishDrawer dishwasher
DD90SDF(H)TX2, DD90SDFTM2 (Designer)
& DD90S(H)TI2 (Integrated) models
NZ AU GB IE
590202B 12.11
ملخص المحتوى في الصفحة رقم 2
2 1 FOLLOW THE INSTALLATION SEQUENCE RELEVANT TO YOUR MODEL ONLY AVAILABLE IN NZ AU ONLY AVAILABLE IN GB IE Designer Integrated (Remote control) Integrated (Badge control) DD90STI2 DD90SHTI2 DD90SDF(H)TX2 DD90SDFTM2 PARTS SUPPLIED PARTS SUPPLIED + PARTS SUPPLIED EXTERNAL VENTING KIT PRODUCT & CABINETRY PRODUCT & CABINETRY DIMENSIONS PRODUCT & CABINETRY DIMENSIONS DIMENSIONS CAVITY PREPARATION CUSTOM FRONT CUSTOM FRONT PANEL CALCULATIONS PANEL CALCULATIONS MAXIMUM DISTANCE OF HOSES & CORD FRO
ملخص المحتوى في الصفحة رقم 3
3 2a SAFETY AND WARNINGS - ALL MODELS WARNING! IMPORTANT SAFETY INSTRUCTIONS! Installation of this dishwasher requires basic mechanical and electrical skills. Electrical shock hazard Be sure to leave these Instructions with the Customer. Before installing the dishwasher, remove the house fuse or open the circuit Installation must comply with your local building and electricity regulations. breaker. At the completion of the dishwasher installation, the Installer must perform the
ملخص المحتوى في الصفحة رقم 4
4 3a PARTS SUPPLIED - ALL MODELS Side mounting Drain hose Drain hose Clamp (1) Phillips 38 mm Rubber Moisture Wire clip (1) bracket kit support (1) joiner (1) 16 mm bottom washer for protection (for securing (for securing (A and B) (2) screws (7) fixing screws inlet hose (1) tape (1) Drain hose joiner) Drain hose joiner) & metal OPTIONAL (comes (to prevent washers (2) already moisture fitted) damage) If the Drain hose supplied is not long enough to reach your services, you must use a Drai
ملخص المحتوى في الصفحة رقم 5
5 3b ADDITIONAL PARTS SUPPLIED WITH INTEGRATED MODELS External Venting kit (1) Panel bracket (1) Panel mounting Integrated rectangular badge (1) (attached to product) screws (14) (Satin chrome supplied) supplied with Integrated models with remote (NZ AU) only supplied with Integrated models with badge (GB IE) only
ملخص المحتوى في الصفحة رقم 6
Integrated Badge control Integrated Remote control Designer 6 4 PRODUCT DIMENSIONS K H A I G Plan Side D C F J B E Product dimensions (mm) 1 overall height of product (incl. front panel height) 478 478 478 A B overall width of product 895 min. 855 min. 855 2 2 C overall depth of product (excl. handle) 571 571 571 depth of chassis (to back of front panel) 553 553 553 D 2 2 E maximum extension of drawer (excl. handle) 545 545 545 F depth of front panel (excl. handle) 18 16-20 16-20 1 height of ch
ملخص المحتوى في الصفحة رقم 7
Integrated Badge control Integrated Remote control Designer 7 5 CABINETRY DIMENSIONS O N O N 18 mm Plan P LM Side 20 mm 2 mm Minimum clearances from adjacent cabinetry min. 13 mm clearance from a min. 2 mm Cabinetry dimensions mm corner cupboard clearance to adjacent cupboard door height of cavity (from support surface to underside 480 480* 480* L of benchtop) M inside height of cavity 460 min. 460 min. 460 N inside width of cavity 864 864 864 overall width of cabinetry 900 900 900 O P ins
ملخص المحتوى في الصفحة رقم 8
8 6a INTEGRATED MODELS WITH REMOTE (NZ AU) ONLY - CUSTOM FRONT PANEL CALCULATIONS min. 2mm FRONT PANEL SPECIFICATIONS 16 -20 mm panel thickness O Adequately sealed to withstand moisture (50 C @ 80% RH) Maximum weight of panel: 9 kg The following calculations assume the top of the panel is aligned with the top of the adjacent cabinetry: A min. 2mm min. 2mm WIDTH OF THE PANEL Measure A (the width between adjacent door/drawer fronts) WIDTH OF PANEL and write it in the fi rst box below, th
ملخص المحتوى في الصفحة رقم 9
9 6b INTEGRATED MODELS WITH BADGE (GB IE) ONLY - CUSTOM FRONT PANEL CALCULATIONS min. 2mm FRONT PANEL SPECIFICATIONS 16 -20 mm panel thickness O Adequately sealed to withstand moisture (50 C @ 80% RH) Maximum weight of panel: 9 kg The following calculations assume the top of the panel is aligned with the top of the adjacent cabinetry: A min. 2mm min. 2mm WIDTH OF THE PANEL Measure A (the width between adjacent door/drawer fronts) WIDTH OF PANEL and write it in the fi rst box below, the
ملخص المحتوى في الصفحة رقم 10
10 7a CAVITY PREPARATION 10 mm BENCHTOP Important! Moisture The power outlet must be protection located in a cabinet adjacent tape must to the dishwasher cavity. be applied. 2 mm 220-240 VAC min. 7 A Water Connection Recommended COLD (Maximum 60°C). These marks indicate ¾ “ BSP (GB20) to formed bracket screw suit flat washer. locations, if securing by drawer removal. Water Pressure Water softener models Max. 1 MPa (145 psi) min. ø 60 mm Services can be Min. 0.1 MPa (14.5 psi) locat
ملخص المحتوى في الصفحة رقم 11
11 INTEGRATED MODELS WITH REMOTE (NZ AU) ONLY - PREPARATION FOR EXTERNAL VENTING THROUGH SAME CABINET 7b Services can be located either side of dishwasher External Venting kit (1) Shelf cutouts max. 5 mm VENT HOSE ø 60 mm SERVICES 220 mm 100 mm INTEGRATED MODELS WITH REMOTE (NZ AU) ONLY - PREPARATION FOR EXTERNAL VENTING THROUGH ADJACENT CABINET 7c The ø60 mm services hole should be enlarged to accomodate the ø60mm extra venting hose by cutting out some material from External Venting kit (1
ملخص المحتوى في الصفحة رقم 12
12 8 MAXIMUM DISTANCE OF HOSES & CORD FROM CHASSIS EDGE Left hand side Right hand side Drain hose - 2000 mm Drain hose - 1500 mm Drain hose - 2000 mm Drain hose - 1500 mm Inlet hose - 1650 mm Inlet hose - 1650 mm Inlet hose - 950 mm Inlet hose - 37 3⁄8" 950 mm P Power cord ower cord ( (excl. plug) excl. plug) - 750 mm - 750 mm P Power cord ower cord (excl. plug) (excl. plug) - 400 mm - 400 mm V Venting hose - 1265 mm enting hose - 1265 mm VVenting hose - 1925 mm enting hose - 1925 mm (Integrat
ملخص المحتوى في الصفحة رقم 13
13
ملخص المحتوى في الصفحة رقم 14
14 NOW CHOOSE WHICH INSTALLATION METHOD (a) or (b) IS MORE SUITABLE FOR YOUR CABINETRY... RECOMMENDED METHOD (a) - SECURE WITHOUT DRAWER REMOVAL (FRAMELESS CABINETRY ONLY) 10a 9a ATTACH SIDE MOUNTING BRACKETS INTEGRATED MODELS WITH REMOTE (NZ AU) ONLY - ATTACH VENTING HOSE Clip all four side mounting brackets into their slots A B Check that the fitted elbow is rotated using a flat-bladed left or right (depending on the direction screwdriver. Ensure they’re of the routing), then ensure the ve
ملخص المحتوى في الصفحة رقم 15
Airflow 15 11a 12a PULL THROUGH HOSES & MOVE INTO THE CAVITY SECURE THE DRAWER 1 Open the drawer halfway. Using a flat-bladed Vent Hose (Integrated models screwdriver, prise with remote (NZAU) the grey rubber Replace the grey only) plug out of the trim rubber plug back into moulding. the trim moulding and ensure the trim seal is facing forward. 2 3 Using a small Philips screwdriver, screw through the trim vent either moulding, securing the through side mounting bracket same cabine
ملخص المحتوى في الصفحة رقم 16
16 ALTERNATIVE METHOD (b) - SECURE BY DRAWER REMOVAL 9b 10b INTEGRATED MODELS WITH REMOTE (NZ AU) ONLY - PULL THROUGH HOSES & MOVE INTO THE CAVITY ATTACH VENTING HOSE Check that the fitted elbow is rotated left or right (depending Vent Hose on the direction of the routing), (Integrated models then ensure the venting hose is with remote (NZAU) only) securely attached to it. vent either through same cabinet Fitted Elbow or adjacent cabinet as per As you push product in, pull through hoses
ملخص المحتوى في الصفحة رقم 17
Airflow 17 11b 12b REMOVE THE DRAWER SECURE THE DRAWER TO THE CABINETRY Product may The product has three pairs 1 move. Mark of fixing points: chassis position on cavity 4 To prevent kinked hoses, we recommend rotating the drawer Ensure the sound insulation anti-clockwise and is repositioned correctly. resting it on its side after removal. a pair of fixing holes either 1 side on the bottom (use 38 mm fixing screws & washers) 2 2 5 Press the release tabs two pairs of formed in on ei
ملخص المحتوى في الصفحة رقم 18
18 INTEGRATED MODELS WITH REMOTE (NZ AU) ONLY - INSTALLING THE FRONT PANEL 15a 16a ATTACH PANEL TO PANEL BRACKET REMOVE BRACKET FROM PRODUCT WARNING! Important! Electrical Shock Hazard Use all 14 screws provided as shown. Before continuing, ensure that the product is disconnected from the power supply. 2 Failure to follow this warning may result in 16 mm electrical shock, injury or fire. 1 x14 1 2 Align bottom of panel with bottom of bracket 1 3
ملخص المحتوى في الصفحة رقم 19
19 INTEGRATED MODELS WITH REMOTE (NZ AU) ONLY - INSTALLING THE FRONT PANEL 17a EARTH THE PANEL 18a ATTACH PANEL TO PRODUCT Important! Ensure the rubber seal between the drawer and panel is kept in 2 place. 1 WARNING! Electrical Shock Hazard 2 To earth the panel bracket, connect the earth wire from the product to one of the tabs. Any custom metal component (e.g. handle) that extends past the rubber seal must be earthed too. When refitting the Failure to follow these warnings may result
ملخص المحتوى في الصفحة رقم 20
457 mm 69 mm Badge zone 20 INTEGRATED MODELS WITH BADGE (GB IE) ONLY - INSTALLING THE FRONT PANEL & BADGE CONTROLS 15b 16b DETERMINE BADGE CUTOUT LOCATION REMOVE BRACKET & DISCONNECT BADGE WARNING! Electrical Shock Hazard Before continuing, ensure that the product is disconnected from the power supply. 3 Failure to follow this warning may result in electrical shock, injury or fire. 1 2 1 4 17b 18b ROUTE BADGE WIRING THROUGH PANEL ATTACH PANEL TO PANEL BRACKET Important! Use all 14 screws provi