ملخص المحتوى في الصفحة رقم 1
INSTRUCTION MANUAL
3 CCD CAMERA
IK-TF7C
For Customer Use
Enter below the Serial No.
which is located on the
bottom of the cabinet. Retain
this information for future ref-
erence.
Model No.: IK-TF7C
Serial No.:
FCC NOTICE
This equipment has been tested and found to comply with the limits for a Class A digital device, pursu-
ant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference when the equipment is operated in a commercial environ
ملخص المحتوى في الصفحة رقم 2
SAFETY PRECAUTIONS Safety icons This manual contains safety instructions that must be observed in order to avoid potential hazards that could result in personal injuries, damage to your equipment, or loss of data. These safety cautions have been classified according to the seriousness of the risk, and the icons highlight these instructions as follows: Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Indicates a potentially hazardous situ
ملخص المحتوى في الصفحة رقم 3
Note the following instructions when installing. • Do not cover the product by any material. • Do not put the product on an Inflammable material such as carpet or blanket. • Do not put the product in a narrow space, since the heat generated from the product may be difficult to emanate. If you do not follow the above, the heat generated by the product may cause fire. Do not put the product in direct sunshine and/or high temperature. The temperature inside the product may cause fire. Avoid setting
ملخص المحتوى في الصفحة رقم 4
TABLE OF CONTENTS 1. CAUTIONS ON USE AND INSTALLATION ..... 5 7. 3 External Sync ............................................ 22 ( 1 ) External sync signal input conditions ...... 22 2. COMPONENTS ................................................ 5 ( 2 ) External sync frequency range ............... 22 3. ITEMS CONTROLLED BY USING ( 3 ) Using the unit with external sync signal .. 23 ON SCREEN DISPLAY .................................... 6 (3. 1) H (horizontal) phase adjustment ...... 23 4. NAMES
ملخص المحتوى في الصفحة رقم 5
1. CAUTIONS ON USE AND INSTALLATION Carefully handle the units. Handling of the protection cap. • • Do not drop, or give a strong shock or vibration to Keep the protection cap away from children. Chil- the camera. This may cause problems. Treat the dren may put them into mouth or swallow them camera cables carefully to prevent cable problems, accidentally. The protection cap protects the im- such as cable breakdown and loosened connec- age sensing plane when the lens is removed from tions. the c
ملخص المحتوى في الصفحة رقم 6
White Electronic shutter Gain Process Sync Option balance 3. ITEMS CONTROLLED BY USING ON SCREEN DISPLAY Preset value Item Available selections (Factory setting) MODE MANU, SS, E. TRG MANU E. TRG 1P SNR, 1P SR, PW SNR, PW SR, RR 1P SNR MANU speed OFF, 1/100s, 1/250s, 1/500s, 1/1000s, 1/2000s, OFF 1/4000s, 1/10000s, 1/25000s, 1/50000s, 1/1000000s Syncro. Partial scanning OFF 1H/796H~795H/796H, OFF, 2FRM~512FRM OFF scan. Partial scanning 60fps 1H/387H~386H/387H, OFF, 2FRM~512FRM Partial scanning 9
ملخص المحتوى في الصفحة رقم 7
4. NAMES AND FUNCTIONS 1 Prism faceplate 8 DC IN 12V terminal 2 DISP button 4 MENU UP button (AWB) DISP 6 DATA UP (AWB) button MENU DATA DC IN 12V PAGE 7 DATA DOWN button 5 MENU DOWN button 9 DIGITAL terminal 3 PAGE button [ Front ] [ Rear ] 1 Prism faceplate The protection cap is attached on the lens mount portion. After removing the cap, mount the lens. Be careful not to scratch or touch the optical area. DISP button Used when switching the display. 2 PAGE button Used when switching to the men
ملخص المحتوى في الصفحة رقم 8
5. CONNECTION 5. 1 Standard Connection Lens Cable (not included) IK-TF7C DC IN 12V Frame grabber board, Monitor Less than 4 mm image process DC power equipment etc. supply 5. 2 Cautions on Connection • When connecting the camera cables, unplug the power source of the camera and the other equipment connected. • We suggest using a C mount lens made for a 3CCD camera. When using another lens, the best camera performance of this camera may not be obtained. (For example, low resolution may occur, f
ملخص المحتوى في الصفحة رقم 9
6. OPERATION Refer to the item " 5. CONNECTION", connect each equipment correctly. 1 2 Turn on the connected equipment and the power source of the camera. Point the lens at the object, operate the lens iris adjustment, focus adjustment, etc.. 3 Refer to the item "6.1 White Balance", operate the adjustment. 4 5 Refer to the items "6.2 Gain, 7. MODE SETTING BY ON SCREEN DISPLAY", select the necessary items. 6. 1 White Balance For the white balance adjustment for this unit, AWB (Automatic White Bal
ملخص المحتوى في الصفحة رقم 10
Result displayed Meaning AWB NG Automatic white balance adjustment cannot be performed because the NOT AVAILABLE shutter speed mode is E.TRG mode. AWB NG Automatic white balance adjustment cannot be performed for other reasons. Such as no white area is included in an object, etc. MANU (Manual white balance) 2 • Set the MODE to MANU on the WHT BAL menu. (Refer to the item "7.2 (3) WHT BAL (white balance)".) • Shoot a known white object, adjust the white balance adjusting the levels of R GAIN and
ملخص المحتوى في الصفحة رقم 11
7. MODE SETTING BY ON SCREEN DISPLAY Various settings can be controlled on the unit by using the on screen menu displayed on the monitor. The contents once set are memorized even if the power source is turned off, so it is unnecessary to set again when using the unit next time. When the setting is performed, select the menu of the item to be set. 7. 1 Using the Menus When the power is turned on, the normal screen showing only the shooting image appears. Change the output to each screen (video si
ملخص المحتوى في الصفحة رقم 12
7. 2 Menus • Select the menu to change the setting by referring the item "7.1 Using the Menus".) • When the [MENU UP], [MENU DOWN] buttons are pushed, the "→" on the screen moves up and down. Move the "→" to the item to change. Note: When performing the mode setting in the menu display while selecting ON in "PART" and E.TRG in "MODE", the display shows normal mode and then the camera returns the setting mode. ( 1 ) SHUTTER (Electronic shutter) The electronic shutter has three modes; MANU (Man
ملخص المحتوى في الصفحة رقم 13
(1. 2) Changing each setting in SS (synchro. scan) mode Move up down Set by pushing By pushing DATA UP, DOWN MENU UP, DOWN • Shutter mode MANU, SS, E.TRG • Synchro. scanning setting -- SHUTTER -- OFF : 1H/796H↔795H/796H↔OFF↔2FRM↔512FRM 60fps, E.60fps : 1H/387H↔386H/387H↔OFF↔2FRM↔512FRM MODE SS 90fps, E.90fps : 1H/258H↔257H/258H↔OFF↔2FRM↔512FRM SS OFF PART OFF • Partial scanning switch OFF/60fps/90fps/E.60fps/E.90fps (a) Changing the shutter speed setting Set the "→" to SS by p
ملخص المحتوى في الصفحة رقم 14
(1. 3) Changing each setting in E.TRG mode The E.TRG has five modes; 1P SNR, 1P SR, PW SNR, PW SR, RR. First set the "→" to MODE and select E. TRG, then set the "→" to E.TRG and select the desired E.TRG mode. (1. 3. 1) Changing each setting in 1P SNR mode Move up down Set by pushing By pushing DATA UP, DOWN MENU UP, DOWN • Shutter mode MANU, SS, E.TRG -- SHUTTER -- • E.TRG mode 1P SNR, 1P SR, PW SNR, PW SR, RR MODE E.TRG E.TRG 1P SNR • Input trigger pulse setting at 1P SNR and 1P SR TRG.P
ملخص المحتوى في الصفحة رقم 15
(1. 3. 2) Changing each setting in 1P SR mode Move up down Set by pushing By pushing DATA UP, DOWN MENU UP, DOWN • Shutter mode MANU, SS, E.TRG -- SHUTTER -- • E.TRG mode MODE E.TRG 1P SNR, 1P SR, PW SNR, PW SR, RR E.TRG 1P SR • Input trigger pulse setting at 1P SNR and 1P SR TRG.P Input trigger pulse : positive polarity EXP. 16ms Input trigger pulse : negative polarity PART OFF • Exposure time setting at 1P SNR and 1P SR 0.01 ms 0.02 ms 0.4 ms 1 ms 16 ms 0.01 m
ملخص المحتوى في الصفحة رقم 16
(1. 3. 3) Changing each setting in PW SNR mode Move up down Set by pushing By pushing DATA UP, DOWN MENU UP, DOWN • Shutter mode MANU, SS, E.TRG -- SHUTTER -- • E.TRG mode MODE E.TRG 1P SNR, 1P SR, PW SNR, PW SR, RR E.TRG PW SNR TRG.P • Input trigger pulse setting at PW SNR and PW SR PART OFF Input trigger pulse : positive polarity Input trigger pulse : negative polarity • Partial scanning switch OFF/60fps/90fps/E.60fps/E.90fps (a) Changing the polarity of
ملخص المحتوى في الصفحة رقم 17
(1. 3. 4) Changing each setting in PW SR mode Move up down Set by pushing By pushing DATA UP, DOWN MENU UP, DOWN • Shutter mode MANU, SS, E.TRG -- SHUTTER -- • E.TRG mode MODE E.TRG 1P SNR, 1P SR, PW SNR, PW SR, RR E.TRG PW SR TRG.P • Input trigger pulse setting at PW SNR and PW SR PART OFF Input trigger pulse : positive polarity Input trigger pulse : negative polarity • Partial scanning switch OFF/60fps/90fps/E.60fps/E.90fps (a) Changing the polarity of in
ملخص المحتوى في الصفحة رقم 18
(1. 3. 5) Changing each setting in RR mode Move up down Set by pushing By pushing DATA UP, DOWN MENU UP, DOWN • Shutter mode MANU, SS, E.TRG -- SHUTTER -- • E.TRG mode MODE E.TRG 1P SNR, 1P SR, PW SNR, PW SR, RR E.TRG RR PART OFF • Partial scanning switch OFF/60fps/90fps/E.60fps/E.90fps (a) Changing the partial scanning setting 1 Set the "→" to PART by pushing [MENU UP], [MENU DOWN] buttons. Select either OFF/60fps/90fps/E.60fps/E.90fps by pushing [DATA UP]
ملخص المحتوى في الصفحة رقم 19
( 3 ) WHT BAL (White balance) WHT BAL has two modes; AWB, MANU. Set the "→" to MODE, push the [DATA UP], [DATA DOWN], and select mode among AWB, MANU. (3. 1) Changing each setting in AWB (Automatic White Balance) mode Move up down Set by pushing By pushing DATA UP, DOWN MENU UP, DOWN -- WHT BAL -- MODE AWB • White balance mode setting (AWB, MANU) C.TEMP 3200 • Color temperature setting 3200, 5600 (a) Changing color temperature setting 1 Set the "→" to C.TEMP by pushing [MENU UP], [MENU D
ملخص المحتوى في الصفحة رقم 20
( 4 ) PROCESS Move up down Set by pushing By pushing DATA UP, DOWN MENU UP, DOWN -- PROCESS -- • Master pedestal adjustment -64 to 64 M.PED 0 • R pedestal adjustment -64 to 64 R.PED 0 • B pedestal adjustment -64 to 64 B.PED 0 SHAD. MANU • Shading mode setting MANU/OFF MANU 0 • Manual shading adjustment -128 to 127 (4. 1) Changing master pedestal Set the "→" to M. PED by pushing [MENU UP], [MENU DOWN] buttons. 1 Set the master pedestal by pushing [DATA UP], [DATA DOWN] butto