ملخص المحتوى في الصفحة رقم 1
Multi-Function Keyboard Controller
EKB500
User’s Manual v1.13
ملخص المحتوى في الصفحة رقم 2
Table of Contents 1. INTRODUCTION..................................................................................4 2. INSTALLATION.....................................................................................5 2.1. EKB500 KEYBOARD CONNECTION DIAGRAM..........................5 2.2. PACKING LIST .................................................................................5 2.3. Quick Installation and Operation Guide (Work with EPTZ1000).........6 3. FEATURE....................
ملخص المحتوى في الصفحة رقم 3
6.1.3. Position Setting......................................................................... 31 6.1.4. Tour Mode ................................................................................ 32 6.1.5. Alarm to Position/Tour Link...................................................... 34 6.2. To operate an DVR (EDSR900/1600) ............................................... 34 6.2.1. Main setup menu....................................................................... 35 6.2.2. Recording
ملخص المحتوى في الصفحة رقم 4
1. INTRODUCTION The multi-function keyboard controller, EKB500 is designed to control speed dome, integrated DVR, camera, access control and monitor. The EKB500 provides a programmable user’s preferences for extending the flexibility of customers’ requests and furthermore the local alarm signal can be carried out to a remote operation center through RS-485 port in security network system. The access control module will be built to connect the keyboard in the near future. There are 3 hot
ملخص المحتوى في الصفحة رقم 5
2. INSTALLATION 2.1. EKB500 KEYBOARD CONNECTION DIAGRAM EKB500 Subkeyboards Camera 2.2. PACKING LIST Please check accessories in the packing before the installation. 1) EKB500 Multi-function controller keyboard X1 2) User’s manual in CD-ROM format/Hard Copy X1 3) Wiring Box for RS-485 connection X1 4) External Power adapter X1 5) RS-485 terminator X1 5
ملخص المحتوى في الصفحة رقم 6
2.3. Quick Installation and Operation Guide (Work with EPTZ1000) EKB500 and EPTZ1000 (Speed dome) and can work together by using factory default setting. You just need to connect cables by following steps: 1. Connect the RS485 cable to EKB500 and EPTZ1000. 2. Connect a video cable from EPTZ1000 to a monitor. 3. Connect the power to EKB500 and EPTZ1000. After the EPTZ1000 finishes the self-test mode, you can start to operate the EPTZ1000 via the EKB500. To operate the EPTZ1000: UP IRI
ملخص المحتوى في الصفحة رقم 7
3. FEATURE 1. Main function keys Main function keys allow you to switch the control of DVRs, monitors and cameras easily. 2. Three-way Joystick The 3-way Joystick is for controlling speed dome mainly. Shift it right/left and up/down to view right/left and up/down subjects, and turn it clockwise/counter-clockwise to zoom in/out. 3. LCD panel The LCD panel shows operation information, and it has a capability to display maximal 2 x 20 digits. 4. Jog and Shuttle Jog and Shuttle
ملخص المحتوى في الصفحة رقم 8
5. DVR reserved keys DVR reserved keys are for DVRs control mainly. You can operate a DVR that is compatible with EKB500. 6. Speed Dome reserved keys These keys are for Speed Dome control mainly. 7. Number keys Numbers from 0~9, one Clr (clear) key and one Enter (enter) key. 8
ملخص المحتوى في الصفحة رقم 9
4. SETTING After Keyboard powered on, firmware version will be displayed on the panel, and the message will disappear after 3 seconds (Fig.1). After the version display disappears, a display with 3 main categories that are CAM (Camera), MON (Monitor) and DVR (Digital Video Recorder) will show on the LCD panel (Fig.2). Keyboard CAM:0001 MON:0001 Version 1.13 ____ [ CAM / MON / DVR ] Fig. 1 Fig. 2 Some settings have many items (options).
ملخص المحتوى في الصفحة رقم 10
COM Port Setting Device Setting The structure of setup menu shows below: COM Port Setting Device Setting Camera Setting Monitor Setting DVR Setting Camera List & Delete Monitor List & Delete DVR List & Delete Non-listed Device Keyboard setting Sub Keyboard Setting MENU Password Lock Password Alarm Password Buzzer ON/OFF Joystick Calibration Keypad Test Jog & Shuttle Test Load default setting Firmware update 10
ملخص المحتوى في الصفحة رقم 11
4.1. COM PORT SETTING Select “COM Port Setting” (The line is Port : _ ( 1 or 2 ) flashing), and press Enter to enter the Input the port. COM Port Setting, or Esc to go back main setup menu. Key in the port you want to set (1 or 2), and then press Enter. Switch Joystick up/down to change the BAUD : 9600 < Baud Rate, and then press Enter. The [ ] to change available Baud Rates are 1200, 2400, 4800 and
ملخص المحتوى في الصفحة رقم 12
keyboard, all devices should be set with the same protocols and Baud Rate. 4.2. DEVICE SETTING 4.2.1. Camera Setting Assign a name from 0~9999 to the Camera Name : _ _ _ _ camera. The name can be different from the RS485 address. RS485 Connected to Select the RS485 port number to which Port : _ [ 1 or 2 ] the camera connects. RS485 Address:
ملخص المحتوى في الصفحة رقم 13
4.2.2. Monitor Setting Assign a name from 0~9999 to the Monitor Name : _ _ _ _ monitor. Assign the monitor to an output channel of Video Connected to DVR : _ _ _ _ Matrix : _ _ a DVR. Press Enter to save the setting of the Monitor : 0001 changed monitor. [ ENT ] to save Press Esc to quit the setting of the monitor without saving. 4.2.3. DVR Se
ملخص المحتوى في الصفحة رقم 14
DVR Type : Select the DVR brand and model name. EDSR1600 < The available models now are EDR410, EDR810, EDR1620, EDR1640, EDSR400H, EDSR400, EDSR600, EDSR900 and EDSR1600. DVR : 0000 set Press Enter to save the setting of the [ ENT ] to save camera. Press Esc to quit the setting of the camera without saving. 4.2.4. Camera List & Delete In the Camera List & Delete menu, you can
ملخص المحتوى في الصفحة رقم 15
number. DVR: The DVR to which the camera is connected. CH: The channel number to which the camera is connected. Switch Joystick up/down to change the cameras. Del Camera0000 Press Enter for a camera you want to [ ENT ] to confirm. delete. Press Enter again to confirm. 4.2.5. Monitor List & Delete In the Monitor List & Delete menu, you can check all available monitors. You can also delete a monitor from the list. Total 005 Monitors
ملخص المحتوى في الصفحة رقم 16
Switch Joystick up/down to change the Monitor. Del Monitor0000 Press Enter for a Monitor you want to [ ENT ] to confirm. delete. Press Enter again to confirm. 4.2.6. DVR List & Delete In the DVR List & Delete menu, you can check all available DVRs. You can also delete a DVR from the list. Total 005 DVRs Show the DVR amount. Press Enter to [ ENT ] to view list view DVR list, or press Esc to quit. Name RS4
ملخص المحتوى في الصفحة رقم 17
4.2.7. Non-listed Device In the Non-listed Device menu, you can set the keyboard only control the listed device or not. The message indicates the non-listed Allow Operation w/o device operation is allowed. Switch list [ ] to toggle Joystick up/down to disable it, and then press Esc to quit. The message indicates the non-listed No Operation w/o device operation is disabled. Switch list [ ] to
ملخص المحتوى في الصفحة رقم 18
Note: Up to 8 keyboards can be connected, and each keyboard has to have an exclusive ID to indicate each keyboard on the RS-485 bus. The master keyboard ID has to value as 0 and the subkeyboards can be set from 1 to 7 as its value. 4.3.2. MENU Password You may lock the setup menu to protect unauthorized operation. Input new Password : Input a new menu password. _ _ _ _ _ _ _ _ Repeat Password :
ملخص المحتوى في الصفحة رقم 19
message will show up on the display. Setup menu password set but disabled. 4.3.3. Lock Password You may lock the Keyboard to protect unauthorized operation. Input new Password : Input a new keyboard lock password. _ _ _ _ _ _ _ _ Repeat Password : Repeat the new keyboard lock _ _ _ _ _ _ _ _ password. Enable Lock password Switch Joystick up/down to select NO < [ ] to change YE
ملخص المحتوى في الصفحة رقم 20
Lock password set but disabled. 4.3.4. Alarm Password Alarm would not be turned off before the operator key-in a password to terminate it. The keyboard is equipped with a buzzer for acoustic signals when an alarm is enabled. Input new Password : Input a new alarm password. _ _ _ _ _ _ _ _ Repeat Password : Repeat the new alarm password. _ _ _ _ _ _ _ _ Enable Alarm Passwd