ملخص المحتوى في الصفحة رقم 1
Planning Information
Integrated Gas Cooktop
MODEL CT15G/S
Medium 12,000 Btu/hr
(3.5 kW) burner
Low-profile Two-tiered
continuous grates control knobs
Model CT15G/S
Illuminated
control panel
Location of
rating plate
Seamless drawn pan Small 9,200 Btu/hr
(2.7 kW) burner
New features make cooking a greater pleasure than
The Wolf Model CT15G/S 15" (381)
integrated gas cooktop is available in
ever. For instance, at higher settings the patented Dual
natural or LP gas with classic stainless
Stacked Bu
ملخص المحتوى في الصفحة رقم 2
Planning Information Integrated Gas Cooktop MODEL CT15G/S FEATURES Integrated design allows for installation of Individual spark ignition system multiple cooktops or modules True Simmer setting on both burners Available in natural and LP gas Illuminated control panel with two-tiered Stainless steel top construction with classic control knobs stainless steel finish Low-profile, cast iron continuous burner Two dual-stacked, sealed burners with grates with matte porcelain finish automatic reignitio
ملخص المحتوى في الصفحة رقم 3
Planning Information Integrated Gas Cooktop MODEL CT15G/S SPECIFICATIONS Overall Cooktop Width 15" (381) Overall Cooktop Height 4" (102) Overall Cooktop Depth 21" (533) Model CT15G/S Burner Rating One 12,000 Btu/hr (3.5 kW) burner with 800 Btu/hr (.2 kW) delivered at simmer MODEL OPTIONS One 9,200 Btu/hr (2.7 kW) burner with 300 Btu/hr (.1 kW) delivered at simmer Classic Stainless Steel CT15G/S 3 Minimum Cabinet Depth 22 /4" (578) Natural gas model listed, for LP gas add (-LP) to the model numb
ملخص المحتوى في الصفحة رقم 4
Planning Information Integrated Gas Cooktop MODEL CT15G/S INSTALLATION SPECIFICATIONS 33" (838) RECOMMENDED 13" max (330) CABINET WIDTH 30" (762) 18" 7"*min (178) COUNTERTOP TO (457) CUT-OUT TO 14" (356) COMBUSTIBLE 1 1 2 /2"** 19 /4" (489) COMBUSTIBLE COOKTOP CUT-OUT MATERIALS 1 (64) COOKTOP CUT-OUT 2 /2"min MATERIALS WIDTH ABOVE COOKTOP DEPTH (64) (BOTH SIDES) 4" (102) E G 15" 36" (914) (381) STANDARD FLOOR TO COUNTERTOP HEIGHT 15" (381) LOCATION OF GAS LOCATION OF GAS SUPPLY SUPPLY MAY ALSO
ملخص المحتوى في الصفحة رقم 5
Planning Information Integrated Gas Cooktop MODEL CT15G/S INSTALLATION NOTES Refer to the illustrations and specifications Wolf gas cooktops are designed to operate for overall dimensions, cut-out dimensions and on natural gas at 5" (12.5 mb) WC (water installation specifics. column) pressure or LP gas at 10" (25 mb) WC pressure. The minimum line pressure for natural When multiple integrated cooktop modules gas is 7" (17.5 mb) WC and 11" (27.4 mb) WC are installed side by side, refer to the coun
ملخص المحتوى في الصفحة رقم 6
Planning Information Integrated Gas Cooktop MODEL CT15G/S MULTIPLE COOKTOP INSTALLATION With Wolf's integrated modules, you have the IMPORTANT NOTE: When multiple cooktops ultimate in customization. You can create your and/or modules are installed side by side, each own design by mixing and matching the various unit must have its own separate recommended components within this system. And when you electrical circuit. When multiple gas cooktops couple these modules with other cooktops and/or modu