Q-Logic QLogicQLE2362 user manual

User manual for the device Q-Logic QLogicQLE2362

Device: Q-Logic QLogicQLE2362
Category: Computer Hardware
Manufacturer: Q-Logic
Size: 0.45 MB
Added : 1/12/2014
Number of pages: 24
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Q-Logic QLogicQLE2362. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Q-Logic QLogicQLE2362.

For your convenience

If looking through the Q-Logic QLogicQLE2362 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Q-Logic QLogicQLE2362 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Q-Logic QLogicQLE2362 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Q-Logic QLogicQLE2362 User manual - Online PDF
Advertisement
« Page 1 of 24 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Q-Logic QLogicQLE2362 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Q-Logic QLogicQLE2362. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Sim p lif y
Q
QLE2360/2362 User’s Guide
2-Gbps Fibre Channel to PCI Express
Host Bus Adapters
PX2454601-00 C Page i

Summary of the content on the page No. 2

QLE2360/2362 User’s Guide 2-Gbps Fibre Channel to PCI Express Host Bus Adapters Q Information furnished in this manual is believed to be accurate and reliable. However, QLogic Corporation assumes no responsibility for its use, nor for any infringements of patents or other rights of third parties which may result from its use. QLogic Corporation reserves the right to change product specifications at any time without notice. Applications described in this document for any of these products are

Summary of the content on the page No. 3

Table of Contents Section 1 Introduction 1.1 How to Use this Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 1.2 General Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 1.3 What is Fibre Channel? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 1.4 Technical Support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 1.4.1 Availability . .

Summary of the content on the page No. 4

QLE2360/2362 User’s Guide 2-Gbps Fibre Channel to PCI Express Host Bus Adapters Q Tables Table Page 2-1 HBA Operating Environment and Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4 Page iv PX2454601-00 C

Summary of the content on the page No. 5

Section 1 Introduction 1.1 How to Use this Guide The SANblade QLogic host bus adapters (HBAs) supported in this document are described in the following paragraphs; they are collectively referred to as the QLE2360/2362 HBA unless otherwise noted. ■ QLE2360 (single channel, half size, full-height bracket, optical media) ■ QLE2362 (dual channel, half size, full-height bracket, optical media) The QLE2360/2362 is a PCI Express to Fibre Channel optical media host adapter. First, install the

Summary of the content on the page No. 6

1 – Introduction Technical Support Q Fibre Channel supports data transfer rates up to 200 MBps half-duplex and 400 MBps full-duplex on optical interfaces. The QLE2360/2362 HBA uses a multimode optical interface for intermediate distances (less than 500 meters at the data rate of 1 Gbps; less than 300 meters at the data rate of 2 Gbps). With its increased connectivity and performance, Fibre Channel is the I/O technology preferred and used by system designers. 1.4 Technical Support Customers

Summary of the content on the page No. 7

1 – Introduction Technical Support Q Fax: +1 952-932-4018 Email: Technical Service support@qlogic.com Technical Training tech.training@qlogic.com HBA Support Web Site: support.qlogic.com PX2454601-00 C 1-3

Summary of the content on the page No. 8

1 – Introduction Technical Support Q 1-4 PX2454601-00 C

Summary of the content on the page No. 9

Part I Hardware This part of the QLE2360/2362 User’s Guide describes the host bus adapters (HBAs) and how to install and configure them. Section 3 contains troubleshooting information. HBA Section QLE2360/2362 2 PX2454601-00 C I-1

Summary of the content on the page No. 10

I – Hardware Q Notes I-2 PX2454601-00 C

Summary of the content on the page No. 11

Section 2 QLE2360/2362 2.1 QLE2360/2362 HBA Components Figure 2-1 identifies the QLE2360/2362 HBA components referenced throughout this section. The J2 transceiver and associated LED is only for the dual channel QLE2362. The QLE2360 is single channel; it uses only one of these transceivers. Each QLE2360/2362 HBA has a unique serial number; its location on the HBA is noted in figure 2-1. Take a minute to write down the serial number of the QLE2360/2362 HBA. LED1 TRANSCEIVERS ISP CHIP J

Summary of the content on the page No. 12

2 – QLE2360/2362 Installation in the Computer Q 2.1.1 LEDs Figure 2-2 identifies and describes the activity of the QLE2360/2362 HBA LEDs. The red LED on the bracket is not used. For more information about the beacon LED activity, see the SANsurfer FC HBA Managers User’s Guide (FS0054601-00). RED LED Activity Green LED Amber LED Red LED AMBER LED GREEN LED Power Off Off Off Off J1 CONNECTOR LEDs Power On (Before On Off Off J1 CONNECTOR Firmware Init) Online, 1Gb/s link One flash Off Off J2 CONN

Summary of the content on the page No. 13

2 – QLE2360/2362 Installation in the Computer Q Perform the following steps to install the QLE2360/2362 HBA in your PC: 1. Check the motherboard and make any configuration changes necessary to accommodate the QLE2360/2362 HBA. 2. Power down the peripherals, then the computer. 3. Remove the computer cover and save the screws. 4. Choose any PCI Express bus slot (x4 or higher). NOTE: If you select a slot higher than x4 lane width, make sure that the slot supports x4 or x1 lane widths. The PC may

Summary of the content on the page No. 14

2 – QLE2360/2362 Specifications Q If the information displayed is not correct and you have checked the QLE2360/2362 HBA’s configuration, see section 3 for troubleshooting information. 2.2.1 Installation Help If your system has an IDE hard disk, it may be assigned device number 80, which is the boot device. If your system does not have an IDE hard disk, a parallel SCSI host bus adapter, or a RAID adapter, the first bootable FC hard disk configured (the one with the lowest ID) is assigned devi

Summary of the content on the page No. 15

2 – QLE2360/2362 Specifications Q Table 2-1. HBA Operating Environment and Specifications Fibre Channel Specifications Data rate 2/1 Gbps auto-negotiation (2.1240/1.0625 Gbps) Compliance Second Generation FC Generic Services Definition (FC-GS-2), Third Generation FC Generic Services Definition (FC-GS-3), Fibre Channel-Physical and Signaling Interface (FC-PH), SCSI-3 Fibre Channel Protocol (SCSI-FCP), Fibre Channel-Arbitrated Loop-2 (FC-AL-2), Fibre Channel-Private Loop Direct Attach Technic

Summary of the content on the page No. 16

2 – QLE2360/2362 Label Q Table 2-1. HBA Operating Environment and Specifications Software ® ® Applications SANsurfer FC HBA Manager, SANsurfer FC CLI ® ™ Operating Windows Server 2003; Windows 2000; Linux Red Hat AS 3.0; systems Linux SuSE SLES 8, 9; Novell NetWare 6.5 HW platforms IA32 (x86), IEM64T Flash utilities Utilities for firmware, driver, boot code, and NVRAM Boot support BIOS Compliance SNIA HBA API V2, SMI-S, FC-SP/DH-CHAP, and FDMI 2.4 Label The transceiver on the QLE2360/2362 HB

Summary of the content on the page No. 17

2 – QLE2360/2362 Agency Certification Q ❑ EN55022:1998/CISPR22:1997 Class A ❑ Radiated Emission Class A ❑ Conducted Emission Class A ❑ EN55024:1998 ❑ Immunity Standards ❑IEC61000-4-2:2001 ESD ❑ IEC61000-4-3 :2002 RF Electro Magnetic Field ❑IEC61000-4-4:2001 Fast Transient/Burst ❑IEC61000-4-5:2001 Fast Surge Common/Differential ❑ IEC61000-4-6 :2003 RF Conducted Susceptibility ❑ IEC61000-4-8 : 2001 Power Frequency Magnetic Filed ❑ IEC61000-4-11: 2001 Voltage Dips and Interrupt ❑ EN61000-3-

Summary of the content on the page No. 18

2 – QLE2360/2362 Agency Certification Q Class User Information Guide A class equipment As this equipment has undergone EMC registration (Business purpose for business purpose, the seller and/or the buyer is info/telecommunications asked to beware of this point and in case a wrongful equipment) sale or purchase has been made, it is asked that a change to household use be made. ■ CNS 13438 Class A ❑ This is a class A product. In domestic environment this product may cause radio interference i

Summary of the content on the page No. 19

2 – QLE2360/2362 Agency Certification Q ❑ EN60825-1:1994+A1+A2 ❑ EN60825-2:1994+A1 PX2454601-00 C 2-9

Summary of the content on the page No. 20

2 – QLE2360/2362 Agency Certification Q 2.5.3 Laser Safety ■ FDA Notice ❑ This product complies with DHHS Rules 21CFR Chapter I,Subchapter J. This product has been designed and manufactured according to IEC60825-1 on the safety label of laser product. ■ Class 1 Laser Product ❑ Appareil A Laser De Classe 1 ❑ Laser Klasse 1 Nach IEC 60825-1 ❑ Luokan 1 Laserlaite ■ Caution—Class 1 laser radiation when open ❑ Do not view directly with optical instruments ■ Attention—Radiation laser de classe 1 ❑ N


Alternative user manuals
# User manual Category Download
1 Q-Logic QLogicQLE2360 User manual Computer Hardware 0
2 Q-Logic QLogicQLA12160 User manual Computer Hardware 1
3 Q-Logic QLogicQ L E 4 0 6 0 C User manual Computer Hardware 0
4 Q-Logic QLogic4010C User manual Computer Hardware 0
5 Q-Logic QLogic4010 User manual Computer Hardware 0
6 Q-Logic QLogicQLA4050C User manual Computer Hardware 2
7 Q-Logic QLogicQLE4062C User manual Computer Hardware 3
8 Q-Logic QLogicQLA2300 User manual Computer Hardware 0
9 Q-Logic QLogicQLA4052C User manual Computer Hardware 1
10 Q-Logic QLogicQL A 4 0 5 0 User manual Computer Hardware 0
11 Sony MSAKIT-PC4A User manual Computer Hardware 2
12 Sony MRW62E-S1 2694866142 User manual Computer Hardware 5
13 Philips MATCH LINE 9596 User manual Computer Hardware 17
14 Sony 64GB SDHC Class 10 Memory Card Readers SF32UY User manual Computer Hardware 1
15 Philips PSC702 User manual Computer Hardware 1