Raritan Engineering Crown Head II user manual

User manual for the device Raritan Engineering Crown Head II

Device: Raritan Engineering Crown Head II
Category: Marine Sanitation System
Manufacturer: Raritan Engineering
Size: 0.38 MB
Added : 3/7/2013
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Raritan Engineering Crown Head II. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Raritan Engineering Crown Head II.

For your convenience

If looking through the Raritan Engineering Crown Head II user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Raritan Engineering Crown Head II on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Raritan Engineering Crown Head II to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Raritan Engineering Crown Head II User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Raritan Engineering Crown Head II but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Raritan Engineering Crown Head II. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1


crown head II
ELECTRIC MARINE TOILET
OPERATION, MAINTENANCE, and INSTALLATION INSTRUCTIONS
Manufactured after June 2002
THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND
FOLLOWED DURING BOTH INSTALLATION AND OPERATION.
WARNING: Raritan Engineering Company, Inc. recommends that a qualified person or electrician install this
product. Equipment damage, injury to personnel or death could result from improper installa-
tion. Raritan Engineering Company, Inc. accepts no responsibi

Summary of the content on the page No. 2

• Push Button Switch (#164000) Press and hold switch until all waste is cleared from bowl. NOTE: Push Button Switch flushing is shown. Refer to manuals included with Toilet Control (TC12W), Raritime Solid State Timer with Solenoid (#RTC), or Flush Control (#SWF100) for operation Instructions. • No special toilet paper is required. • Water should appear in the bowl within ten seconds of flushing. If not, see troubleshooting section. • Hard objects or stringy substances (paper towels, feminine h

Summary of the content on the page No. 3

MAINTENANCE C.P. MAINTENANCE Cleaning Instructions IMPORTANT: Do not use cleaners that contain ammonia, ethyl acetate, phosphoric acid or concentrated chlorine bleach. These will cause damage to the toilet. Using C.P. (#1PCP22), a bio-enzymatic toilet bowl cleaner (available from Raritan Engineering), will keep the bowl clean and fresh smelling. Recommend Visual Inspection ✔ For leaks at toilet and hose connections ✔ Hose clamps ✔ Condition of hoses ✔ Seacocks ✔ Condition of wires and connect

Summary of the content on the page No. 4

WINTERIZING IMPORTANT • Improper winter lay up is a major cause of marine toilet failure. • Use only nontoxic antifreeze. • Flush toilet several times to clear waste from system. • Dispose of all antifreeze in accordance with local and federal regulations. • Winterize holding tanks, plumbing, treatment systems (MSD’s), etc. independently following manufacturer’s instructions. Sea Water Model Parts Required • 1 1/2" (38mm) I.D. piece of hose, approximately 3 feet (1m) long • 3/4" (19mm) I.D. piec

Summary of the content on the page No. 5

WINTERIZING Pressurized Fresh Water Model Parts Required • 1 1/2" (38mm) I.D. hose, approximately 3 feet (1m) long • Two buckets • Nontoxic antifreeze approximately 1 quart (1 liter) Steps 1. Close discharge seacock Nontoxic antifreeze 2. Shut off intake water at source. 3. Turn off power to unit. 4. Disconnect and drain discharge hose. 5. Disconnect intake hoses from vacuum breaker and place in one of the buckets. 6. Connect hose to toilet’s discharge and place in the other bucket. 7. Pour ant

Summary of the content on the page No. 6

INSTALLATION Parts Included • Fuse/circuit breaker All Toilets Tools Required Toilet Bowl (Household or Marine) • 5/16" nut driver Seat and Cover • Wrench or screw driver (depending on mounting fastener) Discharge pump assembly • Bit for drilling mounting surface (depending on Heavy Duty Push Button Switch (#164000) fastener used) Mounting pads • Wire cutters Lower Motor Cover • Wire terminal crimpers Sea Water Model • Hose cutters Remote Intake Pump • Tape measure 3/4" Hose Barb straight fittin

Summary of the content on the page No. 7

INSTALLATION SPECIFICATIONS Bowl Depth: Bowl Width: 14 3/8" (36.6cm) Household 19 1/4" (48.9cm) Household 16 3/4" (42.6cm) Marine 13" (33cm) Marine Height: 17 3/8" (44.1cm) Household 17" (43.2cm) Marine Base Depth: Base Width: 10 1/2" 10 7/8" (27.6cm) (26.8cm) Plumbing Maximum suction of Intake pump 4 Ft. (1.2m) from Intake Pump (Maximum height above waterline) Maximum height of discharge 6 Ft. (1.8m) from base of toilet vented loop Pressurized water source must provide a minimum flow rate of

Summary of the content on the page No. 8

Mounting Toilet Mounting surface must be flat and solid. IMPORTANT: Do not mount where it may be subject to shower spray or other sources of external water. 1. Install seat on toilet. 2. Place toilet where it will be located. Make sure there is room to route hoses. Make sure seat will open properly. 3. Mark location of toilet base mounting holes on mounting surface. 4. Drill holes for toilet mounting bolts/screws. NOTE: Hole size will depend on type of bolt/screws used (5/16" [8mm] size bolts/

Summary of the content on the page No. 9

INSTALLATION ➔ Mounting Atmospheric Vacuum Breaker 6" (Pressurized Freshwater Model only) (15.3cm) 1. Install fittings as shown. 2. Locate mounting area that is a minimum of 6" (15.3cm) above toilet. 3. Secure where top is in horizontal position. Mounting In-Line Strainer (Seawater Models Only) Make sure strainer bowl is tight. 1. Locate strainer where it will be accessible. 2. Mark and drill mounting holes. Flow Marking NOTE: Hole size will depend on type of bolts/ screws used (1/4" [6mm] size

Summary of the content on the page No. 10

Remote Intake Pump Model PLUMBING Mounted Above Waterline Remote Crown head II WARNING: Hazard of Flooding Discharge Intake Vented Pump Toilets mounted at or below the waterline must Loop have a vented loop installed in the discharge Holding Tank line. The top of the vented loop must be a minimum of 4" (10cm) above the waterline at Waterline Waterline In-Line the boats greatest angle of heel (see vented loop Strainer Y Valve manufacturer’s instructions). Lectra/San Intake Discharge Seacock Sea

Summary of the content on the page No. 11

INSTALLATION Intake Lines From Pressurized Freshwater Source Pressurized Freshwater Models (Shut Off Valve) Install a shut off valve in intake line before water solenoid valve. 1. Connect hose from pressurized freshwater source to a shut off valve. 2. Connect hose from shut off valve to inlet port IN of water solenoid valve. OUT NOTE: To avoid malfunction of water solenoid due to debris in water, installation of Freshwater Strainer (FWSC*) is recommended. To Inlet Port of 3. Connect hose from o

Summary of the content on the page No. 12

WIRING WARNING: Hazard of Shock and Fire • Always use proper wire, wire connectors and fuse/circuit breaker. See Specification Chart on page 7. • Secure wire properly. • Do not connect other appliances to toilet Remote Intake Pump Wiring circuit. • Make sure power is off before proceeding. NOTE: Figures shown with installation of Push Push Button Switch Button Switch (#164000). (#164000) Refer to manuals included with Toilet Control (TC*+), Raritime Solid State Timer with Solenoid (#RTC), or

Summary of the content on the page No. 13

TROUBLESHOOTING TROUBLESHOOTING Problem Possible Cause Conclusion A. Poor Discharge, A1. Clogged or restricted discharge line. A1. Be sure discharge seacock is open. Clean lines. Remove clog. Especially Solids: A2. Too many bends or ells in discharge line. A2. Replumb to eliminate bends and ells. A3. Clogged holding tank or vented loops. A3. Clean vents and any vent valves. A4. Mineral buildup in hoses and fittings. A4. Manually clean affected parts and/or replace hoses. A5. Low voltage. A5. C

Summary of the content on the page No. 14

CROWN HEAD II - Parts List Part # Description Part # Description 1118 Lockwasher (4) C250 Beaded Wire Tie 1222AW 90 Degree discharge (opt.) C253 Joker Valve 1222B Straight discharge C290 Discharge Adapter 1226B 1/4" - 20 S/S Hex Nut (4) CH119MWDischarge Impeller Assy. includes CH119M, 1234 Bowl Gasket F149VT [2]) 1236AW Bowl Spud Assembly CH120 Discharge Pump Wall 1236E Bowl Elbow CH121 Macerator 1237W Marine-size Bowl Assembly (White) CH15DD End Bell (Not shown) CH18W Front Cover w/"O" Ring 1

Summary of the content on the page No. 15

EXPLODED PARTS CROWN HEAD II - EXPLODED PARTS VIEW 1237W, 1244AW, 1244W C250 1236AW 1226B 1236E RNI CH26 CH18W 161107 CH120 CH38 Water Solenoid Valve F149VT CH121 CH119MW 1234 PLA14 CH15DD CWPS*A CR1 CH59 C246, 247 CH57 CH34 M30 F149VT M31 M23 CH58 CH92 PLA14 CH27 C290 C2M* In-Line Strainer C253 1341 163000 CH55 1222B 1118 1222AW CH51 Atmospheric Vacuum Breaker PLAVB0-5 PLA13 1660*A 162300W PLA13 PLA14 F005 162325A F020 162200W 162410 162305 162425 162320 162225 162420 162415 162310 162315 162

Summary of the content on the page No. 16

LIMITED WARRANTY Raritan Engineering Company warrants to the original purchaser that this product is free of defects in materials or workmanship for a period of one year from the product’s date of purchase. Should this product prove defective by reason of improper workmanship and/or materials within the warranty period, Raritan shall, at its sole option, repair or replace the product. 1. TO OBTAIN WARRANTY SERVICE, Consumer must deliver the product prepaid, together with a detailed description


Alternative user manuals
# User manual Category Download
1 Raritan Engineering PST*02 User manual Marine Sanitation System 0
2 Raritan Engineering PST*03 User manual Marine Sanitation System 3
3 ACS A0565547 User manual Marine Sanitation System 4
4 ACS XFC-S User manual Marine Sanitation System 1
5 American Standard M968757D User manual Marine Sanitation System 1
6 Attwood 4133 User manual Marine Sanitation System 2
7 Attwood 30116 User manual Marine Sanitation System 1
8 Attwood 4131 User manual Marine Sanitation System 1
9 Dometic VACUFLUSH 1600 User manual Marine Sanitation System 9
10 Central Pneumatic Air Compressor 97956 User manual Marine Sanitation System 1
11 Emerson Process Management 51000 User manual Marine Sanitation System 3
12 Hayward Pools HAYWARD POOL SYSTEM CONTROL User manual Marine Sanitation System 13
13 Honda Power Equipment WDP30X User manual Marine Sanitation System 2
14 ATD Tools ATD-8525 User manual Marine Sanitation System 0
15 CMS Products 780 User manual Marine Sanitation System 0