Omega Vehicle Security PHCN-410 user manual

User manual for the device Omega Vehicle Security PHCN-410

Device: Omega Vehicle Security PHCN-410
Category: Electric Heater
Manufacturer: Omega Vehicle Security
Size: 0.3 MB
Added : 10/24/2014
Number of pages: 11
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Omega Vehicle Security PHCN-410. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Omega Vehicle Security PHCN-410.

For your convenience

If looking through the Omega Vehicle Security PHCN-410 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Omega Vehicle Security PHCN-410 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Omega Vehicle Security PHCN-410 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Omega Vehicle Security PHCN-410 User manual - Online PDF
Advertisement
« Page 1 of 11 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Omega Vehicle Security PHCN-410 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Omega Vehicle Security PHCN-410. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

OMEGA... Your Source f
i&trol
Process Measurement and
PHCN-4 10
DATA ACQUISITION pH Controller
TEMPERATURE
@’ Data Acquisition and Engineering
B Thermocouple, RTD & Thermistor
Software
Probes, Connectors, Panels 81 Assemblies
B Communications-Based Acquisition
B Wire: Thermocouple, RTD &Thermistor
Systems
m Calibrators & Ice Point References
B Recorders, Controllers & Process Monitors 0 Plug-in Cards for Apple, IBM &
Compatibles
B Infrared Pyrometers
0 Datalogging Systems
PRESSURE/STRAIN FORCE 0

Summary of the content on the page No. 2

pH Controller Operator ’s Manual Servicing USA and Canada: Call OMEGA Toll Free USA Canada One Omega Drive, Box 4047 976 Bergar Stamford, CT 06907-0047 USA LavaI (Quebec) H7L 5Al PAGE SECTION Telephone: (203) 359-1660 Telephone: (514) 856-6928 FAX: (203) 359-7700 FAX: (514) 8566886 Sales Service: l-800-826-6342 / l-800-TC-OMEGASM Section 1 Getting Started Customer Service: l-800-622-2378 / l-BOO-622-BESTS” l- l the Controller.. ......................................................... 1 .I &pa

Summary of the content on the page No. 3

pH Controller Operator ’s Manual . . 1 .l Unpacking the Controller Section 4 Operating the Controller . . 4.1 Entering PHCN-410 Hi/Lo Setpoints .................................... Remove the Packing List and verify that you have received all 4-l equipment. If you have questions about the shipment, please call 4.1.1 To Enter the Hi Setpoint Value .................................. 4-l the OMEGA Customer Service Department at l-800-622-2378 or 4.1.2 To Enter the Lo Setpoint Value.. ..............

Summary of the content on the page No. 4

Getting Started 1.2 Controller Description 1.3 Keypad Description The OMEGA” PHCN-410 pH controller is a microprocessor-based The PHCN-410 features four keys for entering all set-up pH controller with automatic temperature compensation, a 4-digit parameters and performing calibration. (Refer to Figure l-l). LED display, two SPDT mechanical relays, and a fixed 4-20 mA output. Select setpoint reby modes (Lo and Hi) SElITEMP CAl/ENIER Initiate calibmtion procedure using standard pH buffers 7.00,4.0

Summary of the content on the page No. 5

Installing the Controller . 1.4 Front Panel Displays 2.1 Mounting the Controller Refer to Figures 2-l and 2-2 for panel cutout and meter dimensions. Controller in pH mode P” CAL pH calibration mode; display shows 7.OO,4.01, and 10.01; CAL annunciator off when calibration complete Hi High alarm relay activated lo Low alone relay activated 90 mm +O.l 1.5 General Information c & We recommend that you bench-test all equipment prior to installation. This requires wiring the equipment and checking rel

Summary of the content on the page No. 6

. ‘ . . . , )

Summary of the content on the page No. 7

Installing the Controller Installing the Controller 2.2.2 Making Input Connections 1. Connect the pH combination electrode to the BNC connector on the bock of the unit. The PHCN-410 features Automatic Temperoture Compensotion; however, the temperature value is not 2. If using Automatic Temperoture Compensotion (ATC), connect the displayed. 100 ohm Pt RTD leads of the temperature probe to Terminals 1 ond 2 (no polarity - see Figure 2-3). 2.2.3 Making Output Connections The 100 ohm Pt RTD temperat

Summary of the content on the page No. 8

Calibrating the pH Electrode Installing the Controller Notes 3.1 Calibrating the pH Electrode Calibration of the electrode to the pH meter is essential for accurate pH measurement. It is also necessary to recalibrate the electrode periodically. The frequency of recalibration is system dependent. The pH calibration procedure is as follows: 1. Connect the combinotion pH electrode ond temperoture compensation probe (if using ATC) to the meter (refer to Figure 2-3). 2. Apply power to the instrument

Summary of the content on the page No. 9

Operating the Controller Calibrating the pH Electrode 4. Remove the pH electrode from the pH buffer 7.00. Rinse the electrode with distilled water ond place the electrode in stondord 4.1 Entering PHCN-410 Hi/Lo Setpoints pH buffer 4.01 or 10.01. Press the CAL Key. 4.1. 1 To Enter the Hi Setpoint Value: At this time the “CAL” annunciator light will appear. When the Press the SET/TEMP keypad, until the Hi annunciator is lit on the 1. light goes off, the slope is calibrated. front ponel. 2. Use the

Summary of the content on the page No. 10

Notes Notes

Summary of the content on the page No. 11


Alternative user manuals
# User manual Category Download
1 Omega Vehicle Security DRF-RES Series User manual Electric Heater 0
2 Omega Vehicle Security KHR User manual Electric Heater 0
3 Omega Vehicle Security OM5-C User manual Electric Heater 0
4 Omega Vehicle Security LSC6400 User manual Electric Heater 0
5 Omega Vehicle Security OMEGAFLEX FPU500 User manual Electric Heater 1
6 Omega Vehicle Security KHLV Series User manual Electric Heater 0
7 Omega Vehicle Security SEPHB Series User manual Electric Heater 0
8 Omega Vehicle Security KH User manual Electric Heater 0
9 Omega Vehicle Security SRMU User manual Electric Heater 0
10 Omega Vehicle Security SH73343 User manual Electric Heater 0
11 Omega Vehicle Security SSHB User manual Electric Heater 0
12 Omega Vehicle Security DRF-POT User manual Electric Heater 1
13 A.O. Smith AH - 290 User manual Electric Heater 6
14 A.O. Smith AHD 290 User manual Electric Heater 7
15 A.O. Smith AHDS 290 User manual Electric Heater 0
16 A.O. Smith ST 3000 User manual Electric Heater 5
17 A.O. Smith WATER HEATERS User manual Electric Heater 13