Our goal is to provide you with a quick access to the content of the user manual for Empire Products SR-18T-3. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Empire Products SR-18T-3.

For your convenience

If looking through the Empire Products SR-18T-3 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Empire Products SR-18T-3 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Empire Products SR-18T-3 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Empire Products SR-18T-3 User manual - Online PDF
Advertisement
« Page 1 of 24 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Empire Products SR-18T-3 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Empire Products SR-18T-3. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

INSTALLATION INSTRUCTIONS
AND
OWNER'S MANUAL
UNVENTED
ROOM HEATER
MODELS
SR-10T-3 SR-18T-3 SR-30T-3
SR-30T SHOWN
Installer: Please leave these instructions with
the consumer.
EFFECTIVE DATE
MAY 2004
Consumer: Please retain these instructions
for future use.
This is an unvented gas-fired heater. It
WARNING: If the information in this
uses air (oxygen) from the room in which
manual is not followed exactly, a fire or
it is installed. Provisions for adequate com-
explosion may result causing p

Summary of the content on the page No. 2

TABLE OF CONTENTS SECTION PAGE Important Safety Information ..................................................................................................................... 3 Safety Information for Users of LP Gas ..................................................................................................... 4 Introduction ................................................................................................................................................ 5 Specifications ..

Summary of the content on the page No. 3

IMPORTANT SAFETY INFORMATION THIS IS A HEATING APPLIANCE DO NOT OPERATE THIS APPLIANCE WITHOUT FRONT PANEL INSTALLED. • An unvented room heater having an input rating of • Installation and repair should be done by a QUALIFIED more than 6,000 Btu per hour shall not be installed in a SERVICE PERSON. The appliance should be inspected bathroom. before use and at least annually by a professional service person. More frequent cleaning may be required due to • An unvented room heater having an input r

Summary of the content on the page No. 4

SAFETY INFORMATION FOR USERS OF LP-GAS Propane (LP-Gas) is a flammable gas which can cause fires by point with the members of your household. Someday and explosions. In its natural state, propane is odorless and when there may not be a minute to lose, everyone's safety will colorless. You may not know all the following safety precau- depend on knowing exactly what to do. If, after reading the tions which can protect both you and your family from an following information, you feel you still need

Summary of the content on the page No. 5

INTRODUCTION Instructions to Installer Important 1. Installer must leave instruction manual with owner after All correspondence should refer to complete Model Number, installation. Serial Number and type of gas. 2. Installer must have owner fill out and mail warranty card Well Head Gas Installations supplied with unvented room heater. Some natural gas utilities use "well head" gas. This may affect the 3. Installer should show owner how to start and operate unvented Btu output of the unit. Contac

Summary of the content on the page No. 6

WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS Water vapor is a by-product of gas combustion. An unvented The following steps will help insure that water vapor does not room heater produces approximately one (1) ounce (30ml) of become a problem. water for every 1,000 BTU's (.3KW's) of gas input per hour. 1. Be sure the heater is sized properly for the application, including ample combustion air and circulation air. Unvented room heaters must be used as supplemental heat (a 2. If high humidit

Summary of the content on the page No. 7

GAS SUPPLY The gas line can be routed either through the floor or wall. The gas A gas valve and ground joint union should be installed in the gas line upstream of the gas control to aid in servicing. It is required line opening should be made at this time. Location of the opening by the National Fuel Gas Code that a drip line be installed near the will be determined by the position of floor joists and the valve and gas inlet. This should consist of a vertical length of pipe tee union used for se

Summary of the content on the page No. 8

SR-10T CLEARANCES When facing the front of the appliance the following minimum clearances to combustible construction must be maintained. 12" MAX Left side 6 inches (152mm). Right side 6 inches (152mm). (305mm) Do not install in alcove or closet. Rear wall 0 inches (0mm). Ceiling 24 inches (610mm). 24 " MIN (610mm) Minimum vertical clearance from a projection above the appliance (shelves, window sills, etc.) 14 inches (356mm). 0" (0mm) CLEARANCE 14" MIN Maximum horizontal extension of projection

Summary of the content on the page No. 9

SR-18T CLEARANCES When facing the front of the appliance the following minimum clearances to combustible construction must be maintained. Left side 6 inches (152mm). Right side 6 inches (152mm). Do not install in alcove or closet. Rear wall 0 inches (0mm). Ceiling 36 inches (914mm). 36" (914mm) MIN Minimum vertical clearance from a projection above the appliance (shelves, window sills, etc.) 36 inches (914mm). 6" (152mm) 6" (152mm) Floor (top surface of carpeting, tile, etc.) 2 inches (51mm). MI

Summary of the content on the page No. 10

WALL MOUNT INSTALLATION Refer to Figures 7, 8 and 9 for measurements in order to locate (4) 24 1/8" mounting holes on wall. Figures 7, 8 and 9 are the front views of (613mm) the heaters. 20 1/8" 2" 2" (511mm) (51) 1. Remove lower louver from casing assembly (2 screws). (51) 2. Remove reflector from casing assembly (2 screws). 1 3/32" (28mm) 3. Remove upper louver from casing assembly (2 screws). 11 13/16" (300mm) 7 13/16" (198mm) 1 3/32" 2" 2" (28mm) (51) (51) 18 7/8" 22" (479mm) (559mm) 18 7/8"

Summary of the content on the page No. 11

4. Mount heater onto the (4) screwheads and complete tightening the screwheads to the plastic expansion anchors. Attention! Use the following steps to properly align the upper louver and the reflector with the heat shield. a. When replacing upper louver, be sure the bottom lip of upper louver goes behind the heat shield. b. When replacing reflector, be sure the top lip of reflector goes in front of the heat shield. 5. Connect the gas line. Figure 10 OPTIONAL FLOOR STAND INSTALLATION 1. Align cle

Summary of the content on the page No. 12

LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by • If you cannot reach your gas supplier, call the fire hand. When lighting the pilot, follow these instructions department. exactly. C. Use only your hand to push in or turn the gas control B. BEFORE LIGHTING smell all around the appliance

Summary of the content on the page No. 13

MAIN BURNER FLAME CHARACTERISTICS SR-10T, SR-18T and SR-30T Main Burner Flame (Figure12) 8.Inspect main burner orifice(s) through the rectangular The main burner flame will have a red-orange glow over the opening(s) in the venturi (throat) of the main burner(s). Dust, surface of the ceramic plaques. A few small, hairline cracks may lint and spider webs can accumulate on top of the main burner form over the surface of the ceramic plaques or at the edges of the orifice(s). If necessary, clean main

Summary of the content on the page No. 14

PILOT FLAME CHARACTERISTICS The correct flame will be blue and will extend beyond the 2. Blow air pressure through the holes indicated by the arrows. thermocouple. The flame will surround the thermocouple just This will blow our foreign materials such as dust, lint and below the tip. A slight yellow flame may occur where the pilot spider webs. Tighten nut B also by grasping nut A. flame and main burner flame meet. Figure 14 Figure 13 Warning: Oxygen Depletion Sensor Pilot (Figure 14) Never use n

Summary of the content on the page No. 15

APPLIANCE MAINTENANCE 5. Remove upper louver from casing assembly (2 screws). Removing Pilot/Thermocouple From Main Burner 6. If installed, remove optional blower assembly (4 screws). Assembly 7. Disconnect inlet supply tubing, outlet supply tubing, pilot Attention: The thermocouple CAN NOT be replaced as an supply tubing and thermocouple lead from gas valve. individual item. You must order a new pilot when replacing 8. If heater is attached to wall, disconnect gas supply line from thermocouple.

Summary of the content on the page No. 16

TROUBLESHOOTING 1. Spark electrode does not produce spark. b. INTERLOCK latching device is operative - see "Lighting a. Spark electrode broken - replace. Instructions," Page 12, Step 9. b. Ignitor wire may not be attached to spark electrode - c. Thermocouple not tightened into gas control - tighten attach. thermocouple. c. Ignitor wire damaged - replace. d. Pilot flame not surrounding thermocouple - clean pilot, d. Piezo ignitor defective - replace. see Page 14. 2. Spark electrode produces spark

Summary of the content on the page No. 17

PARTS LIST SR-18T SR-30T PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide. INDEX PART INDEX PART NUMBER NUMBER DESCRIPTION NUMBER NUMBER DESCRIPTION 1 13348 CASING SIDE ASSEMBLY - LEFT 1 13348 CASING SIDE ASSEMBLY - LEFT 2 SR-041 CASING BACK 2 SR-090 CASING BACK 3 R-2313 PIEZO IGNITOR 3 R-2313 PIEZO IGNITOR 4 SR-008 CASING SIDE ASSEMBLY - RIGHT 4 SR-008 CASING SIDE ASSEMBLY - RIGHT 5 SR-113 VALVE BRACKET 5 SR-113 VALVE BRACKET 6 R-6563

Summary of the content on the page No. 18

PARTS VIEW SR-10T Page 18 16009-1-0504

Summary of the content on the page No. 19

PARTS VIEW SR-18T 16009-1-0504 Page 19

Summary of the content on the page No. 20

PARTS VIEW SR-30T Page 20 16009-1-0504


Alternative user manuals
# User manual Category Download
1 Empire Products BF-20-2 User manual Electric Heater 0
2 Empire Products BF-10-2 User manual Electric Heater 0
3 Empire Products SR-10T-3 User manual Electric Heater 0
4 Empire Products VENTED ROOM HEATER RH-25-6 User manual Electric Heater 0
5 Empire Products RH-50-6 User manual Electric Heater 0
6 Empire Products BF-30-2 User manual Electric Heater 3
7 Empire Products VENTED ROOM HEATER RH-35-6 User manual Electric Heater 0
8 Empire Products COMFORT SYSTEMS EE-25-2 User manual Electric Heater 0
9 Empire Products SR-30T-3 User manual Electric Heater 0
10 A.O. Smith AH - 290 User manual Electric Heater 6
11 A.O. Smith AHD 290 User manual Electric Heater 7
12 A.O. Smith AHDS 290 User manual Electric Heater 0
13 A.O. Smith ST 3000 User manual Electric Heater 5
14 A.O. Smith WATER HEATERS User manual Electric Heater 13
15 A.O. Smith ST 1500 User manual Electric Heater 1