Fishman AIRFREE LDS9000 user manual

User manual for the device Fishman AIRFREE LDS9000

Device: Fishman AIRFREE LDS9000
Category: Water Dispenser
Manufacturer: Fishman
Size: 0.83 MB
Added : 9/9/2014
Number of pages: 32
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Fishman AIRFREE LDS9000. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Fishman AIRFREE LDS9000.

For your convenience

If looking through the Fishman AIRFREE LDS9000 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Fishman AIRFREE LDS9000 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Fishman AIRFREE LDS9000 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Fishman AIRFREE LDS9000 User manual - Online PDF
Advertisement
« Page 1 of 32 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Fishman AIRFREE LDS9000 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Fishman AIRFREE LDS9000. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

LDS9000
™ ™
AirF AirPulse ree CA Dispenser Dispenser
Operating Guide

Summary of the content on the page No. 2

Introduction Y Thank ou for purchasing the Fishman LDS9000 TM AirFree dispenser. Our 9000-line of AirFree dispensers uses a patented positive displacement technology to provide the highest level of repeatability of any dispenser utilizing a syringe as a reservoir. We guarantee it. Please spend a few moments familiarizing yourself with the LDS9000 dispenser. Our recommended testing procedures provide an interactive tutorial on the dispenser’s functions. When complete, review the helpful informati

Summary of the content on the page No. 3

Table of Contents Page Getting Started.............................................................................................4 Specifications ...............................................................................................5 Operation.....................................................................................................6 Program Control ..........................................................................................7 How to Use the Control Panel.......

Summary of the content on the page No. 4

Getting Started This manual contains all the information you will need to set up and test TM the 9000 series AirPulse dispensers. • You will find the hook up for the LDAV on pages 10-15. For the MDAV, review 16-19. For the SDAV review 20-23. • Next, pages 24-25 will show your how to set up and test a thick paste-like material. • Finally, pages 26-27 explain how to dispense watery fluids using vacuum control. TM The remainder of the manual applies to all 9000 series AirFree dispensers. First Step

Summary of the content on the page No. 5

Specifications Input Voltage: 100-240 VAC 47-63Hz Max Inrush Current: 3.2A/1.8A Output Voltage: 5.0VDC Output Power: 4.6W Fuse Rating: 1.0A/250 VAC Initiate Circuit: Foot Pedal (dry contact), finger switch Drive Motor: LDAV 7.5 Degree 48 Steps/Rev MDAV 3.75 Degree 96 Steps/Rev SDAV 3.75 Degree 96 Steps/Rev Axial Movement: LDAV .024 Axial Pitch, .0005"/Step MDAV .024 Axial Pitch, .00025"/Step SDAV .012 Axial Pitch, .000125"/Step Control Circuitry: CMOS microprocessor Interface: Tactile key pad

Summary of the content on the page No. 6

Operation The LDS9000 Dispensing System uses a patented Linear Drive System (LDS) to transfer force from the drive motor to the syringe piston. The motor, lead screw and syringe piston are linked mechanically. Each attachment (gun to reservoir, gun to piston, piston to reservoir) is specifically designed to provide zero flexing in the system during a dispense. Simply put, zero flexing is what makes the LDS9000 the world’s most repeatable dispenser. Once the dispense cycle is complete, a programm

Summary of the content on the page No. 7

Program Control LCD Display Power On/Off Control Pad Extend Auto Foot Control Toggle Switches Retract Manual Hand Gun Port Manual/Auto Dispense • Each mode provides you access to different features on the liquid crystal display. Use the Auto/Manual switch to move back and forth from manual mode to automatic mode. • In manual mode, you can use the foot pedal to dispense a deposit or bead “by eye”. You are in manual mode when the Auto/Manual toggle switch is in the dow

Summary of the content on the page No. 8

How to use the Control Pad P SYRINGE:30CC 1 VOLUME: 4.99 Wait 3-5 seconds for on-screen instructions On Screen Instructions When in program mode, if you are not sure what to do wait approximately 3-5 seconds and rolling instructions appear. If you missed them, not to worry, they will repeat until you make an entry. New or Saved Program In Auto Mode hit the NEXT key. Hit the left arrow to enter a new program or hit the right arrow to enter a saved program. Edit the existing program In Auto mode

Summary of the content on the page No. 9

How to Use the Control Pad Erase an Input or Make a Selection In Auto mode when entering a new program or editing, use the left and right arrow keys to erase and input or skip between choices such as multiple saved programs. Use the ENTER key to select a choice. Confirming a Choice In auto or manual, always use the ENTER key to save an input or selection. The NEXT or BACK keys do not save—they only skip to the next choice. The ENTER key saves your data. Jog Between Menu Choices In auto or manua

Summary of the content on the page No. 10

LDS9000 Gun Assembly SureLok™ Retaining Ring Cover Tip Cap Barrel Reservoir TM PosiLok Piston Piston Hub Lead Screw Dispensing Gun LDS9000 Gun 10

Summary of the content on the page No. 11

Attaching the Syringe 1 Remove the end cap from the barrel reservoir. • Make sure a tip cap is on the barrel. 2 Remove the retaining ring from the dispense gun. 3 Holding the dispensing gun with the piston hub pointed upward, place the barrel over the piston hub of the dispense gun. 4 Holding both loosely. Step on the foot pedal until the barrel ears are raised at least 1/4” (.635mm) above the plate. 11

Summary of the content on the page No. 12

Attach the Syringe (continued) Attaching the Syringe (continued) 5 Manually twist the barrel in a clockwise direction until the luer lock connector is finger tight and the ears of the barrel are flush against the retaining plate. It may be necessary to set the EXTEND/RETRACT switch to RETRACT and step on the foot pedal to bring the barrel ears completely flush to the retaining plate. If you set the switch to RETRACT be sure to set it back to EXTEND before proceeding. Note: Do not over-tighten th

Summary of the content on the page No. 13

Removing the Syringe 1 At the end of a dispense program the control unit will display a message: “Remove syringe and press enter.” 2 Remove the retaining ring cover by turning clockwise. 3 Slide the retaining ring cover over the barrel reservoir. 4 Twist the barrel reservoir clockwise to remove it from the piston hub. • Discard the barrel reservoir. • Press ENTER. 13

Summary of the content on the page No. 14

Program Function TM The LDS9000 AirFree Dispensing system allows 10 user-defined programs to be stored in memory, ranging from 0 to 9. The program stores: • Barrel reservoir size • Deposit volume • Dispense rate • Backoff or Pullback • Delay between forward and reverse motion Follow These Steps to Input a Program <-SYRINGESIZE-> 3 5 10 30 • Press the NEXT key 1 1 Use the left and right arrow keys to select your syringe size. .01 cc 2 Enter your dispense volume by using the .00261-12.2335 keypad

Summary of the content on the page No. 15

Program Function 1 To save program, answer YES followed SAVE PROGRAM? by the program number (0-9) of the <- YES NO -> location you wish to save your 1 program. 2 If you want the program to automatically load as the default program when the machine is turned DEFAULT POWER-ON on, answer YES to the default question. <- YES NO -> • Press the foot pedal to dispense the 2 first deposit Follow These Steps to Edit a Program • Press the BACK key to enter the program manager. Tip: The BACK key moves thr

Summary of the content on the page No. 16

Program Function Follow these steps to save a program to a different location. • Press the BACK key to enter the program manager. • Press the NEXT key to enter the Save menu. • Press the left arrow to make the save. • Select a location by pressing a digit from 0-9. STORED PROGRAM <-REPLACE NO-> Tip: If the program you choose already has a saved program you will be asked if you wish or overwrite the program. DEFAULT POWER-ON • Decide if you want your saved program to <- YES NO -> default at sta

Summary of the content on the page No. 17

How to Make a Bead To dispense a continuous bead of fluid instead of a single dot, follow these steps. Extend Auto Foot 1 Switch the AUTO/MANUAL switch to MANUAL. Retract Manual Hand 1 .00261 cc 2 Set the shot size to the lowest setting. .00261-12.2335 2 3 For best results, set the dispense rate to slow, .065 cc/sec to minimize backpressure in the syringe. .065 - 1.567 3 5 STEPS 4 As a beginning point, set drawback to 5 steps 0 - 500 4 5 Keep delay set to zero, then

Summary of the content on the page No. 18

Operating Tips Suggested Tips • The faster you dispense the more backoff you will need. That’s because the speed at which the piston is traveling exceeds the flow rate of the material out of the dispense tip. Therefore, creating internal pressure. More reverse motion is required to get the internal reservoir pressure back to zero. We recommend you start with a slow rate and progress from there. • The LDS9000 positively displaces fluids. That means if you program .02cc’s of fluid, you will get .0

Summary of the content on the page No. 19

Operating Tips Components • Always use Fishman AirFree™ barrel reservoirs and dispense tips. Safely dispose after use. This method prevents contamination, ensures proper safety and provides maximum cleanliness. • The heart of the Linear Drive System (LDS) is the AirFree™ piston. The specially designed luer connection provides a no slip connection assuring the highest deposit repeatability. • Use Fishman FreeFlow™ tapered dispense tips. Small gauge tips will only create backpressure, put stress o

Summary of the content on the page No. 20

Loading the Reservoirs Avoid Air in the Syringe Barrel Trapped air in the fluid creates voids that will make the fluid compressible. Although the LDS9000 Linear Drive System is stable enough to handle most compressible fluids excess air will force the user to use a greater amount of pullback. This will create a greater amount of forward and reverse motion in the syringe during a dispense cycle. Excess motion will put more stress on the fluid being dispensed. The goal is to reduce dispense motion


Alternative user manuals
# User manual Category Download
1 Edelbrock 2475 User manual Water Dispenser 0
2 Sony 2 User manual Water Dispenser 3
3 ADTX User manual Water Dispenser 4
4 Agilent Technologies E4408B User manual Water Dispenser 16
5 AEG PWE9039M User manual Water Dispenser 15
6 Agilent Technologies 8156A User manual Water Dispenser 7
7 Agilent Technologies 8591E User manual Water Dispenser 7
8 Agilent Technologies 8596E User manual Water Dispenser 5
9 Agilent Technologies 8594E User manual Water Dispenser 13
10 Agilent Technologies 8593E User manual Water Dispenser 13
11 Agilent Technologies 856290216 User manual Water Dispenser 1
12 Agilent Technologies 5328B User manual Water Dispenser 1
13 Agilent Technologies E4403B User manual Water Dispenser 29
14 Agilent Technologies 8595E User manual Water Dispenser 3
15 Agilent Technologies E4411B User manual Water Dispenser 44