Minuteman UPS Endeavor user manual

User manual for the device Minuteman UPS Endeavor

Device: Minuteman UPS Endeavor
Category: Power Supply
Manufacturer: Minuteman UPS
Size: 1.95 MB
Added : 12/14/2013
Number of pages: 26
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Minuteman UPS Endeavor. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Minuteman UPS Endeavor.

For your convenience

If looking through the Minuteman UPS Endeavor user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Minuteman UPS Endeavor on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Minuteman UPS Endeavor to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Minuteman UPS Endeavor User manual - Online PDF
Advertisement
« Page 1 of 26 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Minuteman UPS Endeavor but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Minuteman UPS Endeavor. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Endeavor Series
Battery Packs
User's Manual

Summary of the content on the page No. 2

1. Introduction 2 2. Controls and Indicators 6 3. Installation 7 4. Operation 14 5. Troubleshooting 15 6. Replacing the Battery 16 7. Obtaining Service 20 8. Specifications 21 9. Limited Product Warranty 22 © Copyright 2006 1 English

Summary of the content on the page No. 3

English Thank you for purchasing this power protection product. It has been designed and manufactured to provide many years of trouble free service. IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS ! Please read this manual before installing your Endeavor Series Battery Pack, models EDBP24XL, EDBP48XL, EDBP72XL as it provides important informa- tion that should be followed during installation and maintenance of the Battery Packs and batteries allowing you to correctly set up your system f

Summary of the content on the page No. 4

This symbol indicates "Direct Current Supply" This symbol indicates "Equipment Grounding Conductor" CAUTION! Connect the Battery Pack to a two pole, three wire grounding AC wall outlet. The receptacle must be connected to the appropriate branch protection (circuit breaker or fuse). Connection to any other type of receptacle may result in a shock hazard and violate local electrical codes. Do not use extension cords, adapter plugs, or surge strips. CAUTION! To reduce the risk of electrical sh

Summary of the content on the page No. 5

English WARNING: Qualified Service Personnel ONLY must perform the Installation and Servicing of these Battery Packs. MINUTEMAN accepts no liabilities and is not limited to: injury to the Service Per- sonnel, or damages to; the Battery Pack, the UPS, or the connected equipment caused by the incorrect installation or servicing of the Battery Packs. These Battery Packs MUST be operated with their respective UPS models, see the table below: Model # EDBP24XL EDBP48XL EDBP72XL ED1000RM2U ED1500RM2

Summary of the content on the page No. 6

Receiving Inspection After removing your Battery Pack from its carton, it should be inspected for damage that may have occurred in shipping. Immediately notify the carrier and place of purchase if any damage is found. Warranty claims for damage caused by the carrier will not be honored. The packing materials that your Battery Pack was shipped in are carefully designed to minimize any shipping damage. In the unlikely case that the Battery Pack needs to be returned to the manufac- turer, please

Summary of the content on the page No. 7

English INDICATOR PANEL The Charger Active (green) LED illuminates in a steady state when the Charger is on. The Charger Active LED will extinguish when there is no acceptable AC present. The DC Breaker On (green) LED illuminates in a steady state when the DC breaker is in the On position. The DC Breaker On LED will extinguish when the DC breaker is in the Off position. REAR PANEL 1. The DC Circuit Breaker connects and disconnects the DC bus voltage from the Battery Pack to the UPS. The

Summary of the content on the page No. 8

INSTALLATION PLACEMENT These Battery Packs are intended to be install in a temperature controlled environment that is free of conductive contaminants. Select a location which will provide good air circulation for the Battery Pack at all times. Avoid loca- tions near heating devices, water or excessive humidity, or where the Battery Pack is exposed to direct sunlight. Route power cords so they cannot be walked on or damaged. ENVIRONMENTAL Operating Temperature (max) 0 to 40°C (+32 to +104°F) S

Summary of the content on the page No. 9

English RACKMOUNT CONFIGURATION The Battery Pack comes with mounting brackets for the standard 19" (46.5cm) rack. The mounting brackets to fit a 23" (59.2cm) standard rack are also avail- able. The screws for mounting the Battery Pack to the rack are not included (screw size varies with rack size). 1. Locate the mounting bracket screw holes on the side panels of the Battery Pack, at the front of the Battery Pack. NOTE: The mounting brackets can also be mounted in the middle of th

Summary of the content on the page No. 10

TOWER CONFIGURATION The tower configuration allows the user to install the Battery Pack in the up- right position next to the UPS and the tower computer. The tower brackets are provided with the Battery Pack. WARNING: Use two or more people when installing the Battery Pack. Use CAUTION, the Battery Pack is extremely heavy. 1. Once the location of the Battery Pack has been determined, place the tower brackets in the desired location. WARNING: The Battery Pack must be installed in the pr

Summary of the content on the page No. 11

English WALLMOUNT CONFIGURATION (continued) 2. Align the mounting brackets with the mounting bracket screw holes and attach with the six retaining screws. 3. Use the template to mark the screw hole position on the wall. CAUTION, you should always were protective gear for your hands and eyes when operating power tools. 4. Attach the four retaining screws to the wall and make sure that all of the re- taining screws are screwed into structural material. Then clean the area

Summary of the content on the page No. 12

CONNECTING THE BATTERY PACK (QUALIFIED SERVICE PERSONNEL ONLY) NOTE: If you are using these Battery Packs with the Endeavor series UPS, the UPS must be configured so that the UPS will report the correct estimated runtime in the SentryPlus software and to make the Battery capacity bar graph LEDs display properly. See the SentryPlus software User’s Manual to configure the UPS. 1. Make sure that the DC circuit breaker on the rear panel of the Battery Pack is in the Off position. 2. Turn th

Summary of the content on the page No. 13

English CONNECTING THE BATTERY PACK TO AN AC SOURCE These Battery Packs can operate with 115VAC or 230VAC input voltage. Be- fore connecting the Battery Pack to an AC Source, verify that the Battery Pack's dipswitch is set for the proper input voltage. 1. Set the dipswitch on the rear panel of the Battery Pack to the appropriate input voltage. 2. Connect the input power cord for the Battery Pack into the AC Inlet on the Battery Pack. 3. Plug the other end of the input power cord fo

Summary of the content on the page No. 14

7. Before connecting the Battery Pack to an AC Source, verify that the Battery Pack is set for the proper input voltage. Set the dipswitch on the rear panel of the Battery Pack to the appropriate input voltage. Connect the input power cord with the NEMA 5-15P Plug into the AC Inlet on the first Battery Pack. 8. Connect the Daisy Chain power cord from the AC Outlet of the of the first Battery Pack to the AC Inlet of the second Battery Pack. 9. Connect the input power

Summary of the content on the page No. 15

English English SYSTEM OVERVIEW These Battery Packs will extend the runtime capabilities of the UPS. These Battery Packs have internal chargers to properly maintain the internal batter- ies. The charger will operate with 115VAC or 230VAC depending on the dipswitch setting. The Battery Pack will charge the batteries with the DC circuit breaker in the On or Off position as long as the Battery Pack is plugged into the AC wall outlet and there is an acceptable AC voltage present (90 - 130VAC/180

Summary of the content on the page No. 16

Possible Cause What To Do Symptom 1. The input power cord is 1. Plug the input power cord The Charger Active not plugged into the AC wall into the AC wall outlet. LED is not on. outlet. 2. Once commercial power is 2. No commercial power available recheck the LED. available. 3. Check the circuit breaker 3. No AC voltage at the AC at the service panel to see if wall outlet. it is tripped. 4. Internal charger fault. 4. Call for Service. The DC Breaker On 1. The DC circuit breaker 1. Turn the DC cir

Summary of the content on the page No. 17

English REPLACING THE BATTERY (QUALIFIED SERVICE PERSONNEL ONLY) These Battery Packs have an easy to replace hot-swappable batteries. Please read all of the WARNINGS and CAUTIONS before attempting to service the batteries. NOTE: If there is a power interruption while replacing the hot-swappable batter- ies, with the UPS on, the load will not be backed up. This Battery Pack contains potentially hazardous voltages. Do WARNING! not attempt to disassemble the Battery Pack beyond the battery repla

Summary of the content on the page No. 18

CAUTION: Replace the batteries with the same number and type as originally installed in the Battery Pack. These batteries have pressure oper- ated vents. These Battery Packs contain sealed non-spillable maintenance free lead acid batteries. Model # EDBP24XL EDBP48XL EDBP72XL Battery 4-12V8.5Ah 8-12V8.5Ah 6-12V8.5Ah Qty/Rating CSB HR 1234W F2 HR 1234W F2 HR 1234W F2 Part # Panasonic LC-R129 LC-R129 LC-R129 Part # Yuasa REW45-12 REW45-12 REW45-12 Part # BATTERY REPLACEMENT PROCEDURE (QUALIFIED S

Summary of the content on the page No. 19

English 15. Grasp the other battery pull tab and gently pull the battery module out of the Battery Pack and set on the floor. (FIG. 4) NOTE: Use Caution, the battery modules are heavy. 16. Disconnect the battery positive (red) wires. 17. Disconnect the battery negative (black) wires. 18. Disconnect the battery jumper wires. 19. Remove the old batteries from the battery tray. 20. Install the new batteries into the battery tray in the same position as the original batteries. 2

Summary of the content on the page No. 20

FIG. 2 FIG. 3 FIG. 4 19 English


Alternative user manuals
# User manual Category Download
1 Minuteman UPS AT1200, GS1200 (1200VA) User manual Power Supply 5
2 Minuteman UPS AT650, GS650 (650VA) User manual Power Supply 8
3 Minuteman UPS AT2300, GS2300 (2300VA) User manual Power Supply 1
4 Minuteman UPS AT1600, GS1600 (1600VA) User manual Power Supply 1
5 Minuteman UPS CPE 1000 User manual Power Supply 21
6 Minuteman UPS CPE 3000 User manual Power Supply 29
7 Minuteman UPS AT800, GS800 (800VA) User manual Power Supply 2
8 Minuteman UPS CPE 2000 User manual Power Supply 24
9 Minuteman UPS E1500RM1U User manual Power Supply 2
10 Minuteman UPS E1000RM1U User manual Power Supply 0
11 Minuteman UPS E700RM1U User manual Power Supply 1
12 Minuteman UPS ED6000RMXFMR User manual Power Supply 0
13 Minuteman UPS ED6000T User manual Power Supply 95
14 Minuteman UPS ED6200T User manual Power Supply 8
15 Minuteman UPS MBK-E SERIES User manual Power Supply 21
16 Sony AC U50A User manual Power Supply 5
17 Sony AC LS1 User manual Power Supply 2
18 Sony NP-FM30 User manual Power Supply 35
19 Sony NP FX101 User manual Power Supply 1
20 Sony NH-AAA-DA User manual Power Supply 2