gohastings.com Hastings EntertainmentDAVC-5 user manual

User manual for the device gohastings.com Hastings EntertainmentDAVC-5

Device: gohastings.com Hastings EntertainmentDAVC-5
Category: Cable Box
Manufacturer: gohastings.com
Size: 0.25 MB
Added : 3/4/2013
Number of pages: 17
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for gohastings.com Hastings EntertainmentDAVC-5. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with gohastings.com Hastings EntertainmentDAVC-5.

For your convenience

If looking through the gohastings.com Hastings EntertainmentDAVC-5 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual gohastings.com Hastings EntertainmentDAVC-5 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual gohastings.com Hastings EntertainmentDAVC-5 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
gohastings.com Hastings EntertainmentDAVC-5 User manual - Online PDF
Advertisement
« Page 1 of 17 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual gohastings.com Hastings EntertainmentDAVC-5 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to gohastings.com Hastings EntertainmentDAVC-5. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

TELEDYNE
HASTINGS
INSTRUMENTS

INSTRUCTION MANUAL
DIGITAL AVC
(DAVC-4, DAVC-5, DAVC-6)
ISO 9001
CER T IFIED

Summary of the content on the page No. 2

Manual Print History The print history shown below lists the printing dates of all revisions and addenda created for this manual. The revision level letter increases alphabetically as the manual undergoes subsequent updates. Addenda, which are released between revisions, contain important change information that the user should incorporate immediately into the manual. Addenda are numbered sequentially. When a new revision is created, all addenda associated with the previous revision of the

Summary of the content on the page No. 3

Table of Contents 1.0 GENERAL INFORMATION ............................................................................................................................ 4 1.1 FEATURES ....................................................................................................................................................... 4 1.2 SPECIFICATIONS ............................................................................................................................................

Summary of the content on the page No. 4

1.0 General Information This manual contains technical and general information relating to the installation, operation, and calibration of vacuum gauges and gauge tubes manufactured by Teledyne Hastings Instruments (THI). For best performance, THI vacuum gauges should be operated with the appropriate THI gauge tube. Attempting to use a THI vacuum gauge with another manufacturer’s tubes may result in damage to both the gauge and tube. 1.1 Features The THI Digital AVC (DAVC), is a digital r

Summary of the content on the page No. 5

1.3 Compliance data CE Standard Compliance Test Standard SAFETY EN61010 EMC/EMI Family EN61326 CONDUCTED/RADIATED EN55011 ESD EN61000-4-2 RF EN61000-4-3 CONDUCTED IMMUNITY EN61000-4-6 1.4 Safety The following symbols and terms may be found on THI products and/or in THI manuals and indicate important information. When found on the device, this symbol indicates that the operator should refer to the manual for important instructions on the proper use of this device. Whe

Summary of the content on the page No. 6

1.4.3 Calibration Reference Vacuum Gauge Tubes 1000 mTorr Range Tubes Stock # Model # Description THI Reference Tubes employ the same metal thermopiles used in all 55-38 DV-6M 1/8” NPT Standard (Yellow base) THI Vacuum Gauge Tubes. The thermopile is sealed in a glass 55-38R DV-6R 1/8” Ruggedized capsule that has been evacuated, 55-38RS DV-6 1/8” NPT Rohs Rugged baked, out-gassed, and then aged to 55-38S DV-6S 1/8” NPT Rugged/Vibration ensure long-term stability. The sealed

Summary of the content on the page No. 7

2.0 Installation 2.1 Power-I/O Cable The Power-I/O Cable is assembled at the factory as shown in Fig. 1. Its terminal end is finished with stripped wire ends each tinned with lead free solder. This configuration is consistent with the previous, analog version of the AVC and its color coded wire assignment remains the same, as much as possible, considering the additional features of the Digital version. Fig 1 2.2 Power Requirements & Pin Out Supply the DAVC with a well regulated, 12

Summary of the content on the page No. 8

ALARM 1 DIGITAL COMMON ALARM 2 +VDC POWER COMMON DIGITAL COMMON DIGITAL COMMON Fig. 2 Relay Hook Up 174-082010_Digital AVC Page 8 of 17

Summary of the content on the page No. 9

3.0 Vacuum Gauge Operation All THI gauge tubes are shipped with a protective cap or cover at the evacuation port to reduce contamination and prevent damage to the internal thermopile elements. Once the protective cap or cover is removed, a tube can be installed in any convenient position in the vacuum system without adversely affecting calibration or performance. The recommended orientation is with the tube vertical and its stem down. This will aide in preventing condensable materials fro

Summary of the content on the page No. 10

This signal is equal to an amplified tube millivolt signal. This signal will NOT be linearly proportional to the indicated pressure. 1 volt (1.2 for DAVC4-1.2V) will correspond to a system pressure that is at least 1 order of magnitude less than the minimum detectable pressure. Increasing pressure will be indicated by a decreasing voltage. The minimum detectable pressure is 0.2 millitorr for DAVC-5, 1 millitorr for DAVC-6 and 20 millitorr for DAVC-4. The voltage signal can be mapped to

Summary of the content on the page No. 11

Analog Output vs Pressure 100 DAVC6 DAVC4 DAVC4-1.2V 10 DAVC5 1 0.1 0.01 0.001 0.0001 0 0.2 0.4 0.6 0.8 1 1.2 Voltage 174-082010_Digital AVC Page 11 of 17 Pressure (Torr)

Summary of the content on the page No. 12

3.3 Alarm Set point A single set point controls two open collector circuits. Though not the mechanical relays, the two circuits called Alarm 1 (P > SP) and Alarm 2 (P < SP) allow physical monitoring of the state of the vacuum with respect to the set point. Alarm 1 (P > SP), pin #1 (gray), is active when the red LED is ‘ON’ indicating that the pressure is above the set point. Alarm 2 (P < SP), Pin #2 (brown), is active when the green LED is ‘ON’ indicating that the pressure is below the se

Summary of the content on the page No. 13

Character Description Valid Inputs: m Most Significant Digit Of Mantissa 1 - 9 d Decimal Digit 0 - 9 e Exponent 0 - 5 Command Terminator (carriage return) N/A 3.4.2 Interrogation Commands. Command Description Format Sample Response Get Device ID ID Digital AVC Get Current Pressure if A0 is set, current Set Point P Pa: 1.23456e+0 Torr if A2 is set, heater potentiometer setting if A3 is set Get Relay Status RS 1,R1:ON Get

Summary of the content on the page No. 14

digit exponent before being accepted. There are no limit checks on the data; the user is free to choose any value appropriate to his use of the instrument. If the command syntax is not met or if the number is out or range, the Digital AVC will respond with the ASCII codes for ?, and the command will be ignored. 3.4.4 Reset / Initialize Commands Command Description Format Notes: Software Reset / Reset instrument Does not reset or overwrite any parameters saved in non-vol

Summary of the content on the page No. 15

3.6 Gauge Tube Operating Principle Operation of the Hastings gauge tube is based on a low voltage AC bridge that heats a noble metal thermopile. A change in pressure in the gauge tube changes the molecular collision rate and therefore the thermal conduction of the gas or gas mixture surrounding the thermopile. This results in a temperature shift in the AC heated thermocouples A and B (Fig. 6). The resultant temperature shift causes a change in the DC output from couples A and B inversely wi

Summary of the content on the page No. 16

B. Turn the HTR potentiometer on the top panel until the either the voltage measured between pins 6, Analog Signal Common (violet) and 7, Pressure Signal Output (yellow) reads the voltage corresponding to the pressure as read on the Pressure Vs. Voltage chart for the tube being measured or, if using serial communication, until the proper pressure is read while using the streaming P1 command. C. THE LOW END is now adjusted. NOTE: If re-calibration is required you must repeat the High End ad

Summary of the content on the page No. 17

4.0 Warranty 4.1 Warranty Repair Policy Hastings Instruments warrants this product for a period of one year from the date of shipment to be free from defects in material and workmanship. This warranty does not apply to defects or failures resulting from unauthorized modification, misuse or mishandling of the product. This warranty does not apply to batteries or other expendable parts, nor to damage caused by leaking batteries or any similar occurrence. This warranty does not apply to any


Alternative user manuals
# User manual Category Download
1 gohastings.com Hastings EntertainmentDAVC-4 User manual Cable Box 1
2 gohastings.com Hastings EntertainmentDAVC-6 User manual Cable Box 0
3 Sony POC-DA12SP User manual Cable Box 3
4 Sony 170S7 User manual Cable Box 0
5 Sony Trinitron Color Tv User manual Cable Box 1
6 Philips 32PFL66X6H User manual Cable Box 9
7 Philips 37PFL66X6T User manual Cable Box 0
8 Philips 37PFL66X6K User manual Cable Box 0
9 Philips 40PFL66X6K User manual Cable Box 8
10 Philips 32PFL66X6T User manual Cable Box 1
11 Philips 32PFL66X6K User manual Cable Box 0
12 Philips 37PFL66X6H User manual Cable Box 4
13 Philips 40PFL66X6H User manual Cable Box 11
14 Philips 55PFL66X6H User manual Cable Box 2
15 Philips 46PFL66X6T User manual Cable Box 0