Munchkin Gas-Fired Hot Water Circulating Heater user manual

User manual for the device Munchkin Gas-Fired Hot Water Circulating Heater

Device: Munchkin Gas-Fired Hot Water Circulating Heater
Category: Boiler
Manufacturer: Munchkin
Size: 1.8 MB
Added : 9/18/2013
Number of pages: 72
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Munchkin Gas-Fired Hot Water Circulating Heater. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Munchkin Gas-Fired Hot Water Circulating Heater.

For your convenience

If looking through the Munchkin Gas-Fired Hot Water Circulating Heater user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Munchkin Gas-Fired Hot Water Circulating Heater on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Munchkin Gas-Fired Hot Water Circulating Heater to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Munchkin Gas-Fired Hot Water Circulating Heater User manual - Online PDF
Advertisement
« Page 1 of 72 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Munchkin Gas-Fired Hot Water Circulating Heater but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Munchkin Gas-Fired Hot Water Circulating Heater. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

• Installation
Installation
 Startup
Manual
 Maintenance
 Parts
MH18082
WARNING
This manual must only be used by a qualified heating installer/service technician. Read all instructions
in this manual before installing. Perform steps in the order given. Failure to comply could result in
severe personal injury, death or substantial property damage.

Summary of the content on the page No. 2

GAS-FIRED HEATER Installation Manual WARNING If the information in this manual is not followed exactly, a fire or explo- sion may result causing property damage, personal injury or loss of life. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance.  Do not touch any electrical switch: do not use any phone in your building.  Immediately call your gas supplier from a ne

Summary of the content on the page No. 3

GAS-FIRED HEATER Installation Manual CONTENTS Part 1 – Product and Safety Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4,5 Part 2 – How The Heater Operates. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-8 Part 3 – Prepare Heater Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-11 A. Installations Must Comply With: B. Before Locating Heater C. Clearances for Service Ac

Summary of the content on the page No. 4

GAS-FIRED HEATER Installation Manual CONTENTS (CONT’D) F. Exhaust Vent and Intake Air Pipe Installation. G. Heater Removal from a Common Vent System H. Condensate Removal System I. Diagrams for Side Wall Venting Part 8 – Gas Piping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45,46 A. Gas Connection B. Gas Piping C. Gas Table D. Dungs Gas Valve Part 9 – Field Wiring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 5

GAS-FIRED HEATER Installation Manual PART 1: PRODUCT AND SAFETY INFORMATION SPECIAL ATTENTION BOXES The following defined terms are used throughout this manual to bring attention to the presence of hazards of various risk levels or to important information concerning the product. DEFINITIONS DANGER CAUTION DANGER indicates an imminently hazardous CAUTION Indicates a potentially hazardous situation which, if not avoided, will result in situation which, if not avoided, may result in death or serio

Summary of the content on the page No. 6

GAS-FIRED HEATER Installation Manual PART 1: PRODUCT AND SAFETY INFORMATION (CONT’D) supply to circulator. Instead, shut off the gas WARNING supply at a location external to the appliance. Installer — Read all instructions in this manual,  Do not use this heater if any part has been and Munchkin Contender Venting section, under water. Immediately call a qualified before installing. Perform steps in the order service technician to inspect the heater and given. to replace any part of the control

Summary of the content on the page No. 7

GAS-FIRED HEATER Installation Manual PART 1: PRODUCT AND SAFETY INFORMATION (CONT’D can cause internal corrosion in system system to circulate for at least 30 minutes to components. Leaks in heater or piping must be completely blend any trapped water that might repaired at once to prevent make-up water. be in the system with the NSF® listed solution. At this point it is suggested that you check the WINTERIZING THE MUNCHKIN CONTENDER concentration of NSF® antifreeze to be sure that protection is

Summary of the content on the page No. 8

GAS-FIRED HEATER Installation Manual PART 2: HOW THE MUNCHKIN CONTENDER OPERATES (CONT’D) powered and combustion air is flowing. pump. Route low voltage wires through the opening to the left of the low voltage terminal 4. Swirl Plate System strip. (See Field Wiring Instructions Part 9.) The Swirl Plate on the gas valve controls the 12. Condensate drain connection air and gas flow into the burner, which will assure better mixing for improved This is a condensing high efficiency appliance, combust

Summary of the content on the page No. 9

GAS-FIRED HEATER Installation Manual PART 2: HOW THE MUNCHKIN CONTENDER OPERATES (CONT’D) Super Stor Ultra Indirect Water Heater to get a located in the Vision One section of this fast recovery by prioritizing the flow at a higher manual. Optional kit consists of the following temperature than may be needed for the  Outdoor sensor – 7250P-319 central heating circuits (this will require two  Indirect tank sensor – 7250P-325 separate circulators). You must follow the piping, wiring and programmi

Summary of the content on the page No. 10

GAS-FIRED HEATER Installation Manual PART 3: PREPARE MUNCHKIN CONTENDER LOCATION (CONTINUED) NOTICE The Munchkin Contender Heater gas manifold and controls met safe lighting and other performance criteria when heater underwent tests specified in ANSI Z21.10.3 — latest edition. BEFORE LOCATING THE MUNCHKIN CONTENDER 1. Check for nearby connection to:  System water piping  Venting connections 24" FRONT CLEARANCE  Gas supply piping  Electrical power 2. Check area around heater. Remove any comb

Summary of the content on the page No. 11

GAS-FIRED HEATER Installation Manual PART 3: PREPARE MUNCHKIN CONTENDER LOCATION (CONTINUED) the building and properly terminated. The air WARNING intake and exhaust vent piping lengths, routing and termination method must all comply with the The space must be provided with combus- methods and limits given in the Venting section. tion/ventilation air openings correctly sized for all other appliances located in the same space as F. PREVENT COMBUSTION AIR CONTAMINATION the Munchkin Contender heat

Summary of the content on the page No. 12

GAS-FIRED HEATER Installation Manual PART 3: PREPARE MUNCHKIN CONTENDER LOCATION (CONTINUED) in which the appliances remaining connected G. WHEN REMOVING AN EXISTING HEATER to the common venting system are located FROM AN EXISTING COMMON VENT SYSTEM and other spaces of the building. Turn on clothes dryers and any appliance not DANGER connected to the common venting system. Do not install the Munchkin Contender heater Turn on any exhaust fans, such as range into a common vent with any other appl

Summary of the content on the page No. 13

GAS-FIRED HEATER Installation Manual PART 4: PREPARE MUNCHKIN CONTENDER (CONTINUED) D. INSTALLATION STEPS WARNING The wall must be capable of carrying the weight 1) Prior to lifting the Munchkin Contender Heater onto the wall, use the enclosed of the heater and its related components. The template to level and locate the 2 primary weights of the heater are approximately: screws (#12 x 3" [3/16" x 3"]) round head MC-50- 71 lbs. tapping screw leaving about 1/4" under the MC-80- 74 lbs. screw head

Summary of the content on the page No. 14

GAS-FIRED HEATER Installation Manual PART 5: MUNCHKIN CONTENDER PIPING A. RELIEF VALVE NOTICE Connect discharge piping to safe disposal loca- The Munchkin Contender Heater control module tion, following guidelines in the WARNING below. uses temperature sensors to provide both high limit protection and modulating temperature WARNING control. The control module also provides low water protection by sensing the water pressure To avoid water damage or scalding due to relief of the heat exchanger. So

Summary of the content on the page No. 15

GAS-FIRED HEATER Installation Manual PART 5: MUNCHKIN CONTENDER PIPING (CONTINUED) primary/secondary connection. CAUTION 2. Size the piping and components in the space Undersized expansion tanks cause system heating system using recognized design water to be lost from relief valve and makeup methods. water to be added through fill valve. Eventual failure can result due to excessive make-up G. HYDRONIC PIPING WITH CIRCULATORS, water addition. ZONE VALVES AND MULTIPLE HEATERS 2. Expansion tank mu

Summary of the content on the page No. 16

GAS-FIRED HEATER Installation Manual PART 5: MUNCHKIN CONTENDER PIPING (CONTINUED) concentration and inhibitor level. The system 6. Install a circulator as shown in piping details (this section). Make sure the circulator is should be tested at least once a year and as properly sized for the system and friction loss. recommend by the producer of the glycol solution. Allowance should be made for the 7. Install an Expansion Tank on the system expansion of the glycol solution in the system supply.

Summary of the content on the page No. 17

GAS-FIRED HEATER Installation Manual PART 5: MUNCHKIN CONTENDER PIPING (CONTINUED) The chart below represents the various system temperatures and their respective flows and friction loss through the Munchkin Contender which will aid circulator selection. SYSTEM TEMPERATURE RISE CHART 20˚ t25˚ t30˚ t35˚ t 40˚ t45˚ t Friction Flow Friction Flow Friction Flow Friction Flow Friction Flow Friction Flow Model Feet GPM Feet GPM Feet GPM Feet GPM Feet GPM Feet GPM MC-50 6.5' 5 4.5' 4 3' 3.3 2' 2.5 N/

Summary of the content on the page No. 18

GAS-FIRED HEATER Installation Manual MUNCHKIN CONTENDER PIPING (CONTINUED) K. ZONING WITH CIRCULATORS CAUTION It is highly recommended that you carefully 1. Connect heater to system when circulator zoning as shown in 1C and 1D in Piping follow the glycol manufacturer’s recommended Details when zoning with circulators. The concentrations, expansion requirements and heater circulator cannot be used for a zone. It maintenance recommendations (pH additive must supply only the heater loop. breakdown

Summary of the content on the page No. 19

GAS-FIRED HEATER Installation Manual M. CONTENDER PIPING DETAILS Piping symbol legend circulator circulator (w/ integral check valve) (w/ isolation flanges) gate valve pressure reducing valve globe valve diff. pressure bypass ball valve anti-scald mixing valve swing-check valve T/P flow-check valve temperature /pressure gauge spring-loaded check valve 3-way motorized mixing valve hose bib / heater drain Munchkin Contender Heater 4-way motorized mixing valve TRV (straight) purging valve TRV

Summary of the content on the page No. 20

GAS-FIRED HEATER Installation Manual Standard Munchkin Contender Heater ! Drawing 1A (zoning with valves) Space heating mode zone valves see note 6 make-up water P2 closely differential spaced pressure purge tees bypass valve purging valves OFF anti-scald mixing valve Munchkin Contender Heater T/P Super Stor Ultra indirect DHW Tank NOTES: 1. This drawing is meant to show system piping concept only. Installer is responsible for all equipment & detailing required by local codes. 2. All c


Alternative user manuals
# User manual Category Download
1 Munchkin 399M User manual Boiler 2
2 Munchkin Gas-Fired Hot Water User manual Boiler 1
3 Munchkin HIGH EFFICIENCY HEATER with the "925" Controller User manual Boiler 5
4 Munchkin VWH High Efficiency Hot Water Supply User manual Boiler 0
5 Munchkin pmn User manual Boiler 0
6 Sony HDV 1080I HVR-M15N/M15P User manual Boiler 67
7 Sony HDV 1080I HVR-M25N/M25P User manual Boiler 50
8 A.O. Smith 200 User manual Boiler 2
9 A.O. Smith 201 User manual Boiler 7
10 A.O. Smith 750 & 1000 User manual Boiler 6
11 A.O. Smith GB/GW-400 User manual Boiler 10
12 A.O. Smith DB/DW-720-1810 User manual Boiler 1
13 A.O. Smith DB-720 thru 1810 User manual Boiler 0
14 A.O. Smith GB/GW-650 User manual Boiler 3
15 A.O. Smith GB/GW-500 User manual Boiler 5