IDEAL INDUSTRIES 61-324 user manual

User manual for the device IDEAL INDUSTRIES 61-324

Device: IDEAL INDUSTRIES 61-324
Category: Automobile Accessories
Manufacturer: IDEAL INDUSTRIES
Size: 0.89 MB
Added : 4/18/2013
Number of pages: 19
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for IDEAL INDUSTRIES 61-324. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with IDEAL INDUSTRIES 61-324.

For your convenience

If looking through the IDEAL INDUSTRIES 61-324 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual IDEAL INDUSTRIES 61-324 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual IDEAL INDUSTRIES 61-324 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
IDEAL INDUSTRIES 61-324 User manual - Online PDF
Advertisement
« Page 1 of 19 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual IDEAL INDUSTRIES 61-324 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to IDEAL INDUSTRIES 61-324. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1







IDEAL INDUSTRIES, INC.
TECHNICAL MANUAL
MODEL: 61-320
MODEL: 61-322
MODEL: 61-324


The Service Information provides the following information:
• Precautions and safety information
• Specifications
• Performance test procedure
• Calibration and calibration adjustment procedure
• Basic maintenance (cleaning, replacing the battery and fuses)













Form Number: TM61320-2-4
Revision: 2. Date: Sep 2002

Form number TM61320-2-4 Rev 2 Se

Summary of the content on the page No. 2

TABLE OF CONTENTS Page # Introduction 1 1 Precautions and Safety Information 1 Symbols 2 Safety Specifications 3 General Specification 3 Voltage Specifications 4 Current Specifications 5 5 Resistance, Diode, Continuity Specifications 6 Capacitance, Frequency Specifications 7 Physical and environment characteristics 7 Certification and compliance 8 Required Equipment 9 Basic Maintenance Opening the Meter Case 9

Summary of the content on the page No. 3

Page 1 Introduction Warning To avoid shock or injury, do not perform the verification tests or calibration procedures described in this manual unless you are qualified to do so. The information provided in this document is for the use of qualified personnel only. Caution The 61-320, 61-322, and 61-324 contain parts that can be damaged by static discharge. Follow the standard practices for handling static sensitive devices. For additional information about IDEAL INDUSTRIES, INC.

Summary of the content on the page No. 4

Page 2 SAFETY Review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it. To avoid potential hazards, use the product only as specified. CAUTION. These statements identify conditions or practices that could result in damage to the equipment or other property. WARNING. These statements identify conditions or practices that could result in personal injury or lo

Summary of the content on the page No. 5

Page 3 SPECIFICATIONS All specifications are warranted unless noted typical and apply to the 61-320, 61-322 and 61-324. Stated accuracies are at 23ºC ± 5ºC at less than 80% relative humidity and without the battery indicator displayed. General specifications Characteristics Description Display count 6,000 Numeric update rate 1.5 times / sec Polarity display Automatic Overrange display “OL” is displayed Low voltage indicator is indicated Automatic power-off time Automat

Summary of the content on the page No. 6

Page 4 Measurement Characteristics Accuracy is ± (% reading + number of digits) at 23°C ± 5°C, less than 80% R.H. DC Volts Over voltage Range Resolution Accuracy protection 600.0mV 100µV 6.000V 1mV 60.00V 10mV ±(0.5% + 2dgt) 1000V rms 600.0V 100mV 1000V 1V AC Volts Over voltage Range Resolution Accuracy protection 600.0mV 100µV Unspecified 6.000V 1mV ±(0.9% + 5dgt) 60.00V 10mV 1000V rms 50Hz ~ 500Hz 600.0V 100mV * 750V 1V In

Summary of the content on the page No. 7

Page 5 DC Current Over voltage Range Resolution Accuracy protection 600.0µA 1mV 6000µA 1mV 600V rms1A (600) Fast ±(1.0%+2 dgt) blow fuse 60.00mA 10mV 600.0mA 100mV AC Current Over voltage Range Resolution Accuracy protection 600.0µA 1mV 600V rms 6000µA 1mV ±(1.5%+2 dgt) 1A (600) Fast blow 50Hz ~ 500Hz * 60.00mA 10mV fuse 600.0mA 100mV Voltage Burden: µA: <4mV / µA mA: 2V max. *

Summary of the content on the page No. 8

Page 6 Frequency Overload Range Sensitivity Accuracy protection 6000Hz 100mV rms * 60.00KHz Frequency : 600V rms 600.0KHz 0.01%±1digit 6.000MHz 250mV rms 60.00MHz 1V rms * Less than 20Hz, the sensitivity is 1.5V rms. Capacitance Overload Range Accuracy protection 6.000nF 60.00nF 600.0nF 6.000µF ±(1.9% + 8 dgt) 600V rms 60.00µF 600.0µF 6.000mF * * < 100 dgt of reading rolling. Form number TM61320-2-4 Rev 2 September 2002

Summary of the content on the page No. 9

Page 7 Physical and Environmental Characteristics Characteristics Description 158mm x 76mm x 38mm Dimensions (H x W x D) 164mm x 82mm x 44mm (with holster) Weight (with battery) 0.3Kg With holster 0.5Kg Environmental Characteristics Description Temperature operating 0 to + 50ºC Non-Operating -20 to + 60ºC Humidity (operating) < 80% R.H. Altitude Operating 2,000 m (6560 ft.) Non-O

Summary of the content on the page No. 10

Page 8 Required Equipment Required equipment is listed in Table B. If the recommended models are not available, equipment with equivalent specifications may be used. Repairs or servicing should be performed only by qualified personnel. Table B. Required Equipment Equipment Required Characteristics Recommended Model Calibrator AC Voltage Range: 0-750 VAC Fluke 5500 or Wavetek Accuracy: ±0.07% (Basic) 9100 Calibrator or Frequency Range: 40 ~ 1KHz

Summary of the content on the page No. 11

Page 9 Basic Maintenance Warning To avoid shock, remove the test leads and any input signals before opening the case or replacing the battery or fuses. Opening the Meter Case Caution To avoid unintentional short circuit, always place the uncovered meter assembly on a protective surface. When the case of the meter is open, circuit connections are exposed. To open the meter case, refer to Figure 1A and do the following: 1. Disconnect test

Summary of the content on the page No. 12

Page 10 Testing Fuses To test the internal fuses of the meter: 1. Turn the rotary selector switch to the Ω position. 2. To test FS1, plug a test lead into V ΩHz input terminal and touch the probe to the mA input terminal. The display should indicate between 0.0 to 0.2 Ω. FS1 (1A 600V - Bussmann BBS-1 recommended). If display reads higher than 0.2 Ω, replace the fuse. Fuse Replacement Refer to Figure 1B to replace the fuse: Figure 1B Use only a fuse with the amper

Summary of the content on the page No. 13

Page 11 Performance Tests The following performance tests verify the complete operability of the meter and check the accuracy of each meter function against the meter’s specifications. Accuracy specifications are valid for a period of one year after calibration, when measured at an operating temperature of 18ºC to 28ºC and at a maximum of 80% relative humidity. To perform the following tests, it is not necessary to open the case; no adjustments are necessary. Merely make the re

Summary of the content on the page No. 14

Page 12 Table 1 AC Voltage Test: Step Input Frequency Reading 1 5.800V 50Hz 5.743 to 5.857 2 5.800V 500Hz 5.743 to 5.857 3 58.00V 50Hz 57.43 to 58.57 4 58.00V 500Hz 57.43 to 58.57 5 580.0V 50Hz 574.3 to 585.7 6 580.0V 500Hz 574.3 to 585.7 7 750V 50Hz 738 to 762 8 750V 500Hz 738 to 762 6. Turn the rotary switch to “V ” position. 7. Set the calibrator for the voltage from step 1 to 6 in Table 2. 8. Compare the reading on the meter display with the display reading shown in Table 2

Summary of the content on the page No. 15

Page 13 Testing the Capacitance Function The meter measures capacitance by charging the capacitor with a known direct current, measuring the resultant voltage, and calculating the capacitance. If the same capacitance is measured on an impedance bridge, a different reading may result. This variance is likely to be greater at higher frequencies. To verify the accuracy of the capacitance measuring function, do the following: 1. Apply the capacitor to the V ΩHz and COM inputs on the

Summary of the content on the page No. 16

Page 14 Table 5 AC mA Test: Step Source Frequency Reading 1 58.00mA 50Hz 56.93 to 59.07 2 58.00mA 500Hz 56.93 to 59.07 3 580.0mA 50Hz 569.3 to 590.7 4 580.0mA 500Hz 569.3 to 590.7 6. Turn the rotary switch to mA . 7. Apply the inputs for steps 1-2 in Table 6. 8. For each input, compare the reading on the meter display to the reading in Table 6. 9. If the display reading falls outside of the range shown in Table 6, the meter does not meet specification. Table 6 DC Current Test

Summary of the content on the page No. 17

Page 15 Table 8 Frequency Test: Step Source Level Reading 1 5.600KHz 100mV rms 5.598 to 5.602 2 56.00KHz 100mV rms 55.98 to 56.02 3 560.0KHz 100mV rms 559.8 to 56.02 4 5.600MHz 250mV rms 5.598 to 5.602 5 56.00MHz 1V rms 55.98 to 56.02 Calibration Calibrate the meter once a year to ensure that it performs according to specifications. Perform calibration at an ambient temperature of 23ºC ±2ºC and relative humidity of 75% or less Calibration for the Model 61-320, 61-322 and 61-3

Summary of the content on the page No. 18

Page 16 Figure 3 - Calibration Adjustment Points Form number TM61320-2-4 Rev 2 September 2002

Summary of the content on the page No. 19

Page 17 Form number TM61320-2-4 Rev 2 September 2002


Alternative user manuals
# User manual Category Download
1 IDEAL INDUSTRIES 61-320 User manual Automobile Accessories 4
2 IDEAL INDUSTRIES 61-322 User manual Automobile Accessories 5
3 IDEAL INDUSTRIES S 00-S 10011 User manual Automobile Accessories 0
4 Sony RM-X32 User manual Automobile Accessories 2
5 Sony MV-100CAR User manual Automobile Accessories 1
6 Sony DC-FX1 User manual Automobile Accessories 0
7 Sony RM-X33 User manual Automobile Accessories 13
8 Sony RM-X38 User manual Automobile Accessories 3
9 Sony DCC L50 User manual Automobile Accessories 1
10 Sony CDX-T69X User manual Automobile Accessories 4
11 Sony 9 User manual Automobile Accessories 1
12 Sony RM-X1S User manual Automobile Accessories 156
13 Sony PEGA-CC5 User manual Automobile Accessories 1
14 Philips CID3287 User manual Automobile Accessories 0
15 Philips EcoVision 12342ECO User manual Automobile Accessories 1